Skip to main content
Version: 8.1
View as Markdown

system.user.addRole

This function is used in Python Scripting.

Description​

Adds a role to the specified user source. When altering the Gateway System User Source, the Allow User Admin setting must be enabled.

Client Permission Restrictions​

Permission Type: User Management

Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.

Syntax​

system.user.addRole(userSource, role)

Parameters​

TypeParameterDescription
StringuserSourceThe user source to add a role to. Blank will use the default user source.
StringroleThe role to add. Role must not be blank and must not already exist.

Returns​

UIResponse - A UIResponse object with lists of warnings, errors, and info about the success or failure of the add. The contents of the lists are accessible from the getter methods.

  • getWarns() - Returns a list of warning messages that were encountered during the add.
  • getErrors() - Returns a list of error messages that were encountered during the add.
  • getInfos() - Returns a list of "info" messages that were encountered during the add.

These messages represent normal logging events that occurred during the add, and can be useful when trying to visualize the events that lead up to a failure.

Scope​

Gateway, Vision Client, Perspective Session

Code Examples​

Example #1
# This example adds a role "Operator" to the user source "MyUserSource".
system.user.addRole("MyUserSource", "Operator")