Vision - Slider
Component Palette Icon:
The slider component lets the user drag an indicator along a scale to choose a value in a range. The slider can be configured to orient horizontally or vertically.
Properties​
| Property | Description | Property Type | Scripting | Category | 
|---|---|---|---|---|
| Background Color | The background color of the component. | Color | .background | Appearance | 
| Border | The border surrounding this component. Options are: No border, Etched (Lowered), Etched (Raised), Bevel (Lowered), Bevel (Raised), Bevel (Double), Field Border, and Line Border. Note: The border is unaffected by rotation. | Border | .border | Common | 
| Cursor | The mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize. | int | .cursorCode | Common | 
| Defer Updates | Only publish updates to value when not actively being changed. | boolean | .deferred | Behavior | 
| Enabled | If disabled, a component cannot be used. | boolean | .componentEnabled | Common | 
| Font | Font of text on this component. | Font | .font | Appearance | 
| Foreground Color | The foreground color of the component. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector . | Color | .foreground | Appearance | 
| Horizontal Slider | If true, slider is horizontal, otherwise, it's vertical. | boolean | .horizontal | Appearance | 
| Inverted? | Specify true to reverse the value range shown for the slider and false to put the value range in the normal order. | boolean | .inverted | Behavior | 
| Major Tick Spacing | The distance, measured in values, between each major tick mark. | int | .majorTickSpacing | Appearance | 
| Maximum Value | The value when the slider is all the way right or up. | int | .maximum | Data | 
| Minimum Value | The value when the slider is all the way left or down. | int | .minimum | Data | 
| Minor Tick Spacing | The distance, measured in values, between each minor tick mark. | int | .minorTickSpacing | Appearance | 
| Mouseover Text | The text that is displayed in the tooltip which pops up on mouseover of this component. | String | .toolTipText | Common | 
| Name | The name of this component. | String | .name | Common | 
| Paint Labels? | If true, value labels will be shown. | boolean | .paintLabels | Appearance | 
| Paint Ticks? | If true, value tick marks will be shown. | boolean | .paintTicks | Appearance | 
| Paint Track? | If true, the track of the slider will be shown. | boolean | .paintTrack | Appearance | 
| Quality | The data quality code for any Tag bindings on this component. | QualityCode | .quality | Data | 
| Snap To Ticks? | Only allows selection of values at the tick marks. | boolean | .snapToTicks | Behavior | 
| Styles | Contains the component's styles. | Dataset | .styles | Appearance | 
| Value | The current value of the slider. | int | .value | Data | 
| Visible | If disabled, the component will be hidden. | boolean | .visible | Common | 
Deprecated Properties​
| Property | Description | Property Type | Scripting | Category | 
|---|---|---|---|---|
| Data Quality | The data quality code for any Tag bindings on this component. | int | .dataQuality | Deprecated | 
Scripting​
Component Functions​
This component does not have component functions associated with it.
Extension Functions​
This component does not have extension functions associated with it.
Event Handlers​
Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the Component Events page
Customizers​
Examples​
Code Snippet
#The following code will return the value of the slider's previous value into a variable.
#This code is fired on the property change scripting for this component.
oldValue = event.source.oldValue
Vertical Slider with Border and Blue Text​
| Property Type | Value | 
|---|---|
| Maximum Value | 250 | 
| Minor Tick Spacing | 25 | 
| Foreground Color | 0,0,255 | 
| Major Tick Spacing | 50 | 
Horizontal Slider without Tickmarks​
| Property Type | Value | 
|---|---|
| Paint Ticks? | False | 
| Minor Tick Spacing | 0 | 
| Major Tick Spacing | 100 |