Skip to main content

system.security.lockScreen

This function is used in Python Scripting.

Description​

Used to put a running client in lock-screen mode. The screen can be unlocked by the user with the proper credentials, or by scripting via the system.security.unlockScreen() function.

Client Permission Restrictions​

This scripting function has no Client Permission restrictions.

Syntax​

system.security.lockScreen([obscure])

Parameters​

TypeParameterDescription
booleanobscureIf true(1), the locked screen will be opaque, otherwise it will be partially visible. [optional]

Returns​

Nothing

Scope​

Client

Code Examples​

Example #1
# This would run in a timer script to lock the screen after 15 seconds of inactivity, and then log the user out after 30 seconds of inactivity.

if system.util.getInactivitySeconds() > 15 and not system.security.isScreenLocked():
system.security.lockScreen()
elif system.util.getInactivitySeconds() > 30:
system.security.logout()