Skip to main content

system.gui.errorBox

This function is used in Python Scripting.

Description​

Displays an error-style message box to the user.

Client Permission Restrictions​

This scripting function has no Client Permission restrictions.

Syntax​

system.gui.errorBox(message [, title])

Parameters​

TypeParameterDescription
StringmessageThe message to display in an error box. Will accept html formatting.
StringtitleThe title for the error box. [optional]

Returns​

Nothing

Scope​

Client

Code Examples​

Example #1
# Turn on compressor #12, but only if the user has the right credentials.

if 'Supervisor' in system.security.getRoles():
updateQuery = "UPDATE CompressorControl SET running=1 WHERE compNum = 12"
system.db.runUpdateQuery(updateQuery)
else:
errorMessage = "Unable to turn on Compressor 12."
errorMessage += " You don't have proper security privileges."
system.gui.errorBox(errorMessage)