executeQuery
This feature was removed from Ignition in version 8.0.0
This function is used by Ignition's Expression language.
Description​
note
This function is only available in Transaction Group Expression Items and Expression Tags.
Executes a select query using the given ConnectionName (or the default connection it omitted) and stores the result into a global ResultSetName.
Syntax​
executeQuery(query, resultName[, datasource])
Parameters
string query - The query to execute.
string resultName - The name of the global result set.
string datasource - Optional. The name of the database connection.
Results
- int - The number of rows in the returned table.
Examples​
Code Snippet
executeQuery("SELECT * FROM table", "MyResult", "MySQLConnection") //would store the results in "MyResult" and return an integer based on how many rows were in the table.