system.gui.openDiagnostics
note
This function was deprecated in 8.3 and replaced with a system.vision variation.
This function is used in Python Scripting.
Description
Opens the Client runtime Diagnostics window, which provides information regarding performance, logging, active threads, connection status, and the console. This provides an opportunity to open the Diagnostics window in situations where the menu bar in the client is hidden, and the keyboard shortcut (Ctrl + Shift + F7) can not be used.
Client Permission Restrictions
This scripting function has no Client Permission restrictions.
Syntax
system.gui.openDiagnostics()
Parameters
Nothing
Returns
Nothing
Scope
Vision Client
Code Example
Opening Diagnostics Window
# Opens the diagnostics window in a running client
system.gui.openDiagnostics()