Skip to main content
Version: Deprecated Pages
View as Markdown

system.db.runNamedQuery

Deprecated by new system.db functions in 8.3

This function was deprecated in place of new functions to resolve compatibility issues across scopes. Use system.db.execQuery for select queries and system.db.execUpdate for update queries.

Click here to learn more about new system.db functions.

This function is used in Python Scripting.

Description

Runs a Named Query and returns the results. Note that the number of parameters in the function is determined by scope. Both versions of the function are listed below.

This function accepts keyword arguments.

Client Permission Restrictions

This scripting function has no Client Permission restrictions.

Project Scope Syntax

system.db.runNamedQuery(path, [parameters], [tx], [getKey])

Parameters

TypeParameterDescription
StringpathThe path to the named query to run. Note that this is the full path to the query, including any folders.
Dictionary[String, Any]parametersA Python dictionary of parameters for the Named Query to use. [optional]
StringtxAn transaction ID, obtained from beginNamedQueryTransaction. If blank, will not be part of a transaction. [optional]
BooleangetKeyOnly used for Update Query types. A flag indicating whether or not the result should be the number of rows affected (getKey=0) or the newly generated key value that was created as a result of the update (getKey=1). Not all databases support automatic retrieval of generated keys. [optional]

Returns

Any - The results of the query. The exact object returned depends on the Query Type property of the Named Query: typically either a dataset when set to Query, an integer representing the number of rows affected when set to Update Query, or an object matching the data type of the value returned by a Scalar Query.

PyDataset - The results of the Named Query as a PyDataset.

Scope

Vision Client, Perspective Session

Gateway Scope Syntax

system.db.runNamedQuery(project, path, [parameters], [tx], [getKey])

Parameters

TypeParameterDescription
StringprojectThe project name the query exists in.
StringpathThe path to the Named Query to run. Note that this is the full path to the query, including any folders.
Dictionary[String, Any]parametersA Python dictionary of parameters for the Named Query to use. [optional]
StringtxAn optional transaction ID, obtained from beginNamedQueryTransaction. If blank, will not be part of a transaction. [optional]
BooleangetKeyOnly used for Update Query types. A flag indicating whether or not the result should be the number of rows affected (getKey=0) or the newly generated key value that was created as a result of the update (getKey=1). Not all databases support automatic retrieval of generated keys. [optional]

Returns

Any - The results of the query. The exact object returned depends on the Query Type property of the Named Query: typically either a dataset when set to Query, an integer representing the number of rows affected when set to Update Query, or an object matching the data type of the value returned by a Scalar Query.

Scope

Gateway

Code Examples

Simple Example - Without Parameters
# This example runs a Named Query without any parameters in the Project scope.

# Request the Named Query to execute.
system.db.runNamedQuery("folderName/myNamedQuery")
Gateway Scope Example
# This example runs a Named Query without any parameters in the Gateway scope.

# Request the Named Query to execute.
system.db.runNamedQuery("ProjectName", "folderName/myNamedQuery")
Simple Example - With Parameters
# This example runs a Named Query while passing some parameters in the Project scope.
# The Named Query is assumed to have two parameters already defined on the Named Query:
# param1 : A string
# param2 : An integer

# Create a Python dictionary of parameters to pass.
parameters = {"param1":"my string", "param2":10}

# Run the Named Query.
system.db.runNamedQuery("myUpdateQuery", parameters)