# Ignition User Manual
> by Inductive Automation
>
> Version: 8.3
This file contains links to documentation sections following the llmstxt.org standard.
## Table of Contents
- [Welcome](https://www.docs.inductiveautomation.com/docs/8.3/intro.md): 
- [Getting Started](https://www.docs.inductiveautomation.com/docs/8.3/getting-started.md):
- [Command Line Installations](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading/command-line-installations.md): Command line argument keys can be used to modify the installation process. Each operating system supports launching with arguments that contain som...
- [7.9 to 8.1 Upgrade Guide](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading/ignition-8-upgrade-guide/79to81-upgrade-guide.md): Ignition 8.1 is a major update across virtually all subsystems and modules. Inductive Automation strives to maintain its commitment to backwards co...
- [8.0 to 8.1 Upgrade Guide](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading/ignition-8-upgrade-guide/80to81-upgrade-guide.md): This section details notes and advisories for users planning on upgrading from 8.0 to 8.1.
- [8.1 to 8.3 Upgrade Guide](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading/ignition-8-upgrade-guide/81to83-upgrade-guide.md):
- [Ignition 8 Upgrade Guide](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading/ignition-8-upgrade-guide.md): This section contains guides for users that are considering upgrading to newer versions of Ignition.
- [Installing and Upgrading Ignition](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading.md): The installation process for Ignition is designed to be as simple as possible. You can find installers on our Downloads page: https://inductiveauto...
- [Installing or Upgrading a Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading/installing-or-upgrading-a-module.md):
- [ZIP File Installations](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/installing-and-upgrading/zip-file-installations.md): Aside from the graphical installers, our downloads page features ZIP files that can be used to install and run Ignition. The ZIP file installation ...
- [Introducing Ignition](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/introducing-ignition.md): Ignition by Inductive Automation® combines an unlimited licensing model with instant web-based deployment and the industry-leading toolset for supe...
- [OPC COM Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/additional-modules/OPC-COM-module.md): 
- [OPC COM Tunneller Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/additional-modules/OPC-COM-tunneller-module.md): 
- [SECS/GEM Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/additional-modules/SECS-GEM-module.md): 
- [Additional Modules](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/additional-modules.md): Enhance Ignition's capabilities beyond traditional SCADA and HMI limits. These additional modules provide Ignition with even more functionality. Ta...
- [Twilio Notification](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/additional-modules/twilio-alarm-notification.md): 
- [Voice Notification Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/additional-modules/voice-notification-module.md): 
- [Connector Modules](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/connector-modules.md): Connector modules expand Ignition's functionality, allowing users to connect to NoSQL databases such as MongoDB.
- [Kafka Connector](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/connector-modules/kafka-connector.md): This connector is a part of a series of modules called Cloud Connectors. Cloud Connectors are bundled with Ignition Cloud Edition, as they leverage...
- [MongoDB Connector](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/connector-modules/mongodb-connector.md): 
- [SFC Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/SFC-module.md): 
- [SMS Notification Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/SMS-notification-module.md): 
- [Alarm Notification Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/alarm-notification-module.md): 
- [Core Modules](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules.md): Build any kind of human machine interface (HMI) or supervisory control and data acquisition (SCADA) system using Ignition's powerful offering of HM...
- [Enterprise Administration Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/enterprise-administration-module.md): 
- [Event Streams Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/event-streams-module.md): 
- [JDBC Driver Modules](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/jdbc-drivers.md): JDBC drivers are leveraged by Ignition to offer a standardized set of functionality on a wide range of different systems and databases. Although yo...
- [Driver Modules](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/opc-ua-module/driver-modules.md): The following drivers are available for Ignition's OPC UA module.
- [OPC UA Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/opc-ua-module.md): 
- [Perspective Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/perspective-module.md): 
- [Reporting Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/reporting-module.md): 
- [SQL Bridge Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/sql-bridge-module.md): 
- [SQL Historian Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/sql-historian-module.md): 
- [Historian Core Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/tag-historian-module.md): 
- [Vision Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/vision-module.md): 
- [Web Dev Module](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview/core-modules/webdev-module.md): 
- [Modules Overview](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/modules-overview.md):
- [Perspective and Vision - Which Visualization System is Best for Me?](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/perspective-and-vision.md): Ignition's Perspective module and the Vision module each enable you to rapidly develop industrial applications for your site. Perspective is Igniti...
- [Designing a Project](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/startup-guide/designing-a-project.md): This document follows the [Downloading and Installing Ignition](getting-started\startup-guide\downloading-and-installing-ignition\downloading-and-i...
- [Downloading and Installing Ignition](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/startup-guide/downloading-and-installing-ignition.md): This document explains how to download and install Ignition.
- [Startup Guide](https://www.docs.inductiveautomation.com/docs/8.3/getting-started/startup-guide.md): Ignition can seem like an overwhelming system of connections and data. This section outlines how to install Igntion, demonstrates some of the most ...
- [System Architectures](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures.md):
- [AWS Outposts Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/aws-outposts-architecture.md): Amazon Web Services (AWS) Outposts is a fully managed service that offers the same AWS infrastructure, AWS services, APIs, and tools to virtually a...
- [Basic Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/basic-architecture.md): The Basic Architecture consists of a single Gateway that can connect to multiple PLCs, databases, and other devices, all with a single licensed ins...
- [Cloud Based Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/cloud-based-architecture.md): 
- [Edge Architectures](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/edge-architectures.md): The Ignition Edge system is unique in that it can be very flexible and fill in the gaps in any system architecture. Ignition Edge is a smaller vers...
- [Enterprise Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/enterprise-architecture.md): Many types of architecture involve multiple Ignition servers. Eventually, some assistance overseeing each server can be helpful. Enterprise Archite...
- [Hub and Spoke Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/hub-and-spoke-architecture.md): 
- [IIoT Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/iiot-architecture.md): The [Basic Architecture](basic-architecture.md) can easily be expanded with the MQTT modules to collect data from numerous Edge of Network devices....
- [Redundancy Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/redundancy-architecture.md): Any single installation in the System Architectures can be replaced with a redundant pair of Ignition Gateways. If you have a dedicated backup comp...
- [Scale Out Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/scale-out-architecture.md): In the Scale Out Architecture, we have at least one Gateway that handles back-end communications. The back-end Gateway deals with all PLC and devic...
- [Security Architecture](https://www.docs.inductiveautomation.com/docs/8.3/system-architectures/security-architectures.md): Consumers of each class of traffic should communicate with Ignition Gateways, but not with other types of consumers. For example, Ignition communic...
- [Mobile App Changelog](https://www.docs.inductiveautomation.com/docs/8.3/new-in-this-version/mobile-app-changelog.md): General
- [New in this Version 📣](https://www.docs.inductiveautomation.com/docs/8.3/new-in-this-version.md): Over the course of development, naturally there are changes and additions to the Ignition software. This page highlights any new functionality or m...
- [Other Editions](https://www.docs.inductiveautomation.com/docs/8.3/other-editions.md):
- [AMI Access Instructions - AWS](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-cloud-edition/ami-access-instructions-aws.md): :::note Default Ports
- [Cloud Edition - AWS Networking and Security](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-cloud-edition/ami-access-instructions-aws/cloud-edition-aws-networking-and-security.md): This page details various networking and security settings you may need to configure for your Cloud Edition EC2 instance.
- [Cloud Edition Gateway](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-cloud-edition/cloud-edition-gateway.md): The Cloud Edition Gateway is very similar to a standard Ignition Gateway. Many of the features that exist on the standard Ignition platform also ex...
- [Ignition Cloud Edition](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-cloud-edition.md): A cloud architecture-based version of Ignition.
- [Cloud Edition - Azure Networking and Security](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-cloud-edition/image-access-instructions-azure/cloud-edition-azure-networking-and-security.md): This page details various networking and security settings you may need to configure for your Cloud Edition virtual machine.
- [Image Access Instructions - Azure](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-cloud-edition/image-access-instructions-azure.md): 
- [Upgrading Ignition within Cloud Services](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-cloud-edition/upgrading-ignition-within-cloud-services.md): 1. On your EC2 Management Console, navigate to the Instances page located on the left-hand side navigation panel.
- [Configuring Sync Services](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-edge/edge-gateway/configuring-sync-services.md): Synchronization allows you to sync your historian data, audit records, and alarm journal entries from the Edge Gateway to a Standard Ignition Gatew...
- [Edge Gateway](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-edge/edge-gateway.md): The Edge Gateway has many of the same options as the standard [Ignition Gateway Webpage](../../../platform/gateway/web-interface/platform/gateway-s...
- [Edge IIoT](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-edge/edge-iiot.md): 
- [Edge Panel](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-edge/edge-panel.md): 
- [Ignition Edge](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-edge.md): A lightweight, lean version of Ignition with software solutions designed for devices used in the field and edge of the network.
- [Ignition Maker Edition](https://www.docs.inductiveautomation.com/docs/8.3/other-editions/ignition-maker-edition.md): A community version of Inductive Automation's Ignition SCADA application.
- [Launchers and Workstation](https://www.docs.inductiveautomation.com/docs/8.3/launchers-and-workstation.md):
- [Deploying Pre-Configured Launchers](https://www.docs.inductiveautomation.com/docs/8.3/launchers-and-workstation/deploying-pre-configured-launchers.md): In some cases, it may be desirable to deploy a pre-configured Launcher to remote clients. Doing so bypasses the installation process on the remote ...
- [Designer Launcher](https://www.docs.inductiveautomation.com/docs/8.3/launchers-and-workstation/designer-launcher.md):
- [Launcher Settings](https://www.docs.inductiveautomation.com/docs/8.3/launchers-and-workstation/launcher-settings.md): 
- [Perspective Workstation](https://www.docs.inductiveautomation.com/docs/8.3/launchers-and-workstation/perspective-workstation.md):
- [Vision Client Launcher Settings](https://www.docs.inductiveautomation.com/docs/8.3/launchers-and-workstation/vision-client-launcher/vision-client-launcher-settings.md): You can customize your Vision Client Launcher settings through either the GUI or by modifying a [file on the local file system](#launcher-configura...
- [Vision Client Launcher](https://www.docs.inductiveautomation.com/docs/8.3/launchers-and-workstation/vision-client-launcher.md):
- [Ignition Modules](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules.md):
- [Adding Pipelines to Tags](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/adding-pipelines-to-tags.md): Any alarm in Ignition can use an existing alarm notification pipeline on the local Gateway and/or [remote Gateway](ignition-modules/alarm-notificat...
- [Alarm Notification Pipelines](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines.md): Alarm Notification Pipelines are logic diagrams that control how alarm notifications are sent out, including who they are sent to and when. They ca...
- [Alarm Pipeline Designer Interface](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/alarm-pipeline-designer-interface.md): The Alarm Pipeline Designer Interface is where you create your own custom pipelines to control the the flow of an alarm to its notification. It pro...
- [Alarm Pipelines Status](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/alarm-pipelines-status.md): It’s possible to monitor the status of your alarm notification pipelines to see exactly where your alarms are in the notification process in Igniti...
- [Notification Block](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/pipeline-blocks/notification-block.md): As the name suggests, the Notification block is responsible for sending notifications. Each notification block can target multiple notification pro...
- [Pipeline Blocks](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/pipeline-blocks.md): Pipeline blocks are the building blocks for the Alarm Pipeline Notification system. Each block has an input and zero or more outputs. Each block ha...
- [Pipeline - Escalation](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/pipeline-escalation.md): It is possible to set up escalation procedures in [alarm notification pipelines](../alarm-notification-pipelines.md) in Ignition. The following exa...
- [Pipeline - Filter on Alarm Associated Data](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/pipeline-filter-on-alarm-associated-data.md): :::note
- [Pipeline - Filter on Alarm Priority](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/pipeline-filter-on-alarm-priority.md): :::note
- [Pipeline - Simple Loop](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/pipeline-simple-loop.md): :::note This section assumes that alarms are configured
- [Simple Pipeline](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/alarm-notification-pipelines/simple-pipeline.md): The most basic Alarm Notification Pipeline will simply notify users as soon as the [alarm](platform/alarming/alarming.md) becomes active.
- [Alarm Notification](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification.md): The Alarm Notification module allows you to send messages to groups of users when alarms become active, acknowledged, or cleared. This functionalit...
- [Notification Contact Info](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-contact-info.md):
- [Email Alarm Acknowledgement](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/email-notification-profile/email-alarm-acknowledgement.md): Email Alarm Acknowledgement allows operators to acknowledge alarms via a link that is included directly in the email alarm notification. The email ...
- [Email Notification Profile](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/email-notification-profile.md):
- [Notification Profile Types](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types.md): Once you have alarms configured in Ignition, you can notify people when alarms occur. Ignition provides Notification Profile Types that allow email...
- [Remote Gateway Notification](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/remote-gateway-notification.md):
- [Simple One-Way Email Notification Profile](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/simple-one-way-email-notification-profile.md): The Simple One-Way Email Notification Profile is used to notify users when alarms occur, based on priority level. Unlike the standard Email Notific...
- [SMS Notification Profile](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/sms-notification-profile.md):
- [Twilio Notification Profiles](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/twilio-notification-profiles.md): 
- [Twilio SMS Notification](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/twilio-notification-profiles/twilio-sms-notification.md): SMS notifications can be sent with the [Twilio Notification module](getting-started/modules-overview/additional-modules/twilio-alarm-notification.m...
- [Twilio Voice Notification](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/twilio-notification-profiles/twilio-voice-notification.md):
- [Twilio WhatsApp Notification](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/twilio-notification-profiles/twilio-whatsapp-notification.md):
- [Notification Security PIN](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/voice-notification-profile/notification-security-pin.md): You can require users to enter a personal identification number (PIN) before they hear a voice alarm notification. This helps ensure that the perso...
- [Registering Voice Alarm Module to CUCM](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/voice-notification-profile/registering-voice-alarm-module-to-cucm.md): Cisco Unified Communications Manager (CUCM) is a communication system, that can work in tandem with Ignition's Voice Notification module. This page...
- [Voice Notification Profile](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/voice-notification-profile.md):
- [Voice Notification Scripts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/notification-profile-types/voice-notification-profile/voice-notification-scripts.md):
- [On-Call Rosters](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/alarm-notification/on-call-rosters.md):
- [Cloud Connector Modules](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/cloud-connector-modules.md): Cloud Connector modules offer extended functionality to [Ignition Cloud Edition](other-editions\ignition-cloud-edition\ignition-cloud-edition.md) a...
- [Kafka](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/cloud-connector-modules/kafka.md):
- [MongoDB](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/cloud-connector-modules/mongodb.md): **MongoDB** is a non-relational, NoSQL database. Unlike relational SQL databases like Microsoft SQL Server, MongoDB uses a JSON-like structure call...
- [Adding an Agent](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/adding-an-agent.md): To communicate with the controller, agents send data across a Gateway Network connection. If your Gateway Network setup requires that connections b...
- [Agent Management](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-management.md): There are a variety of tools available that allow you to manage certain parts of your agent Gateways that are not scheduled tasks. If your agent go...
- [Agent Recovery](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-management/agent-recovery.md):
- [Automated Agent Installation](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-management/automated-agent-installation.md): The EAM allows an agent Gateway to be automatically configured from text files when the Gateway is started. This capability is enormously useful wh...
- [License Management](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-management/license-management.md):
- [Remote Upgrade](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-management/remote-upgrade.md): Agents can be upgraded remotely from the controller. This involves uploading the required binary files for the desired architecture as a task. Once...
- [Agent Tasks](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-tasks.md): Once the Gateway Network is up, and there is at least one controller and one agent configured, there are a variety of actions that can be performed...
- [Agent Task - Backup and Restore](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-tasks/backup-and-restore.md):
- [Agent Task - Licensing](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-tasks/licensing.md):
- [Agent Task - Scheduling](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-tasks/scheduling.md):
- [Agent Task - Send Project](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-tasks/send-project.md):
- [Agent Task - Send Tags](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/agent-tasks/send-tags.md): The controller can send tags from one or more Tag Providers on the controller to agents.
- [Creating a Controller](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/creating-a-controller.md):
- [EAM in the Designer](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/eam-in-the-designer.md):
- [Enterprise Administration](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration.md):
- [Redundant EAM Configuration](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/enterprise-administration/redundant-eam-configuration.md): * As with any redundant configuration, you cannot make any changes on the backup controller. However, new agents can be added without taking the Ga...
- [Event Streams](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/event-streams.md):
- [Types of Handlers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/event-streams/types-of-handlers.md): This page details each type of handler and what they are used for in an [event stream](ignition-modules\event-streams\event-streams.md).
- [Source Data and Metadata](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/event-streams/types-of-sources/source-data-and-metadata.md): This page details the extractable elements from each source. When pulling data into handlers using expressions, you will need to add curly brackets...
- [Types of Sources](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/event-streams/types-of-sources.md): This page details each source available for [event streams](ignition-modules\event-streams\event-streams.md).
- [JDBC Drivers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/jdbc-drivers.md): The JDBC drivers shipped with Ignition are bundled inside modules. Currently, this includes the MariaDB, MSSQL, PostgreSQL JDBC drivers. It's impor...
- [Ignition's OPC UA Server](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/ignitions-opc-ua-server.md): Ignition's OPC UA server, provided by the [OPC UA module](getting-started\modules-overview\core-modules\opc-ua-module\opc-ua-module.md), allows an ...
- [OPC UA Connections](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-connections.md): | Property | Description |
- [Allen-Bradley Connection Paths](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/allen-bradley-connection-paths.md): Connections to ControlLogix, CompactLogix, PLC-5, MicroLogix and SLC Allen-Bradley processors through a ControlLogix Gateway require a connection p...
- [Allen-Bradley Ethernet](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet.md): Ignition provides several drivers for Allen-Bradley devices. These drivers connect through the Gateway to devices that support Ethernet communicati...
- [Connecting to CompactLogix](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/connecting-to-compactlogix.md): :::note
- [Connecting to ControlLogix](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/connecting-to-controllogix.md): :::note
- [Connecting to Logix](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/connecting-to-logix.md): :::note
- [Connecting to Micro800](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/connecting-to-micro800.md): The Micro800 driver enables Ethernet/IP communication over TCP/IP with Allen-Bradley Micro800 devices, including the 820, 850, and 870 series.
- [Connecting to MicroLogix](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/connecting-to-micrologix.md):
- [Connecting to PLC5](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/connecting-to-plc5.md): :::note
- [Connecting to SLC](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/allen-bradley-ethernet/connecting-to-slc.md): :::note
- [BACnet Local Device](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/bacnet/bacnet-local-device.md): Before you can start communicating with a remote device you must first configure a local device, representing Ignition’s presence as a BACnet devic...
- [BACnet Remote Device](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/bacnet/bacnet-remote-device.md): Once a [local device](ignition-modules\opc-ua\opc-ua-drivers\bacnet\bacnet-local-device\bacnet-local-device.md) has been configured a remote BACnet...
- [BACnet](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/bacnet.md): :::caution
- [DNP3 Driver](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/dnp3/dnp3-driver.md): The DNP3 Driver provides communication with DNP3 outstations over Ethernet, supporting event-based polling, unsolicited messaging, and explicit rea...
- [DNP3](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/dnp3.md): DNP3 is a communication protocol commonly used in water and electric utilities. It connects a central master station to multiple remote devices, kn...
- [DNP3 Driver (Legacy)](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/dnp3/legacy-dnp3-driver.md): The DNP3 Driver (Legacy) uses the [DNP3](../dnp3.md) protocol for explicit reads and unsolicited messaging to acquire data. This driver is no longe...
- [IEC 61850 Driver](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/iec-61850-driver.md): IEC 61850 is a protocol used for power systems that need to send control signals to different types of intelligent electronic devices (IEDs) define...
- [Mitsubishi TCP Driver](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/mitsubishi-tcp-driver.md): The Mitsubishi TCP driver provides a user interface in the Gateway where you can create, import, or export addresses when connected to devices that...
- [Connecting to Modbus Device](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/modbus/connecting-to-modbus-device.md):
- [Modbus Address Mapping](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/modbus/modbus-address-mapping.md):
- [Modbus Addressing](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/modbus/modbus-addressing.md):
- [Modbus](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/modbus.md): Our generic Modbus driver allows the Ignition OPC-UA server to communicate with any device that supports the Modbus TCP protocol or the RTU over TC...
- [Omron FINS Driver](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/omron-fins-driver.md): Ignition supports Omron FINS devices. This driver supports both UDP and TCP transport protocols.
- [Omron NJ Driver](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/omron-nj-driver.md): This driver requires the OPC UA module to be installed and enabled. If the module is missing or disabled, the device will fault with a “Missing Dep...
- [OPC UA Drivers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers.md): A few [Ignition drivers](getting-started\modules-overview\core-modules\opc-ua-module\driver-modules.md) are included on install in the form of modu...
- [Programmable Device Simulator](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/programmable-device-simulator.md): The Programmable Device Simulator allows you to add simulator devices that act as if they are connected to a real device. It allows users to read a...
- [Siemens Drivers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/siemens/siemens-drivers.md): The following Siemens drivers in Ignition connect to PLCs via TCP/IP using the S7 protocol. Similar to Modbus and some Allen Bradley connections, t...
- [Siemens Enhanced Driver](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/siemens/siemens-enhanced-driver.md): :::caution Using the Siemens Enhanced Driver with Ignition 8.3.3+
- [Siemens](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/siemens.md):
- [UDP and TCP Driver](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-drivers/udp-and-tcp-driver.md): Ignition’s UDP and TCP drivers allow communication with simple devices such as barcode scanners and scales. These drivers are not general-purpose P...
- [OPC UA Security Settings](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/opc-ua-security.md): On the OPC UA Security Settings page you can manage [OPC UA](ignition-modules\opc-ua\opc-ua.md) certificates for the client and server. Trusted cer...
- [OPC UA](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua.md): Open Platform Communications (OPC) is a standard for exchanging information between hardware and software through specialized drivers. It’s used to...
- [Connecting to Kepware OPC UA](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/third-party-opc-servers/connecting-to-kepware-opc-ua.md):
- [OPC COM](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/third-party-opc-servers/opc-com.md): :::note
- [Third Party OPC Servers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/opc-ua/third-party-opc-servers.md): Ignition has a built-in OPC UA server that includes all of the drivers in this section, but if your devices aren't listed here, there is another wa...
- [A Vision-Oriented Guide to Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/a-vision-oriented-guide-to-perspective.md): Perspective is a flexible and versatile approach to HMI/SCADA design. Whereas Vision clients run on any platform that supports Java, Perspective Se...
- [Pages in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/pages-in-perspective.md):
- [Perspective Co-Branding](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-co-branding.md): Perspective Co-Branding allows users to customize the look of their Perspective Sessions with logos, pictures, and colors. Various aspects of Persp...
- [Perspective Design Tips](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-design-tips.md): Designing mobile-responsive applications involves several considerations. Your design should work across a range of devices, from small smartphones...
- [Perspective Designer Interface](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-designer-interface.md):
- [Perspective Project Properties](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-project-properties.md): There are a number of properties you can set for your Perspective projects within the Designer. For example, there are properties for setting secur...
- [Ignition Perspective Mobile App](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-sessions/ignition-perspective-app.md):
- [Offline Mode](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-sessions/ignition-perspective-app/offline-mode.md):
- [Reverse Proxy Considerations](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-sessions/perspective-session-proxy-considerations.md): While a forward proxy proxies on behalf of clients (or requesting hosts), a reverse proxy proxies on behalf of servers. There are many possible use...
- [Perspective Sessions](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-sessions.md): A Perspective **Session** represents one instance of a project running on a web browser or mobile app. The term "Session" might be new to some user...
- [Session Properties](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/perspective-sessions/session-properties.md):
- [Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective.md): Perspective is the next generation visualization system for industrial applications, optimized specifically for mobile devices. Perspective puts th...
- [Component Message Handlers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/scripting-in-perspective/component-message-handlers.md):
- [Perspective Component Methods](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/scripting-in-perspective/perspective-component-methods.md): A component method is a function that is defined on a component object. For example, this is how we would call a component method defined on the co...
- [Perspective Property Change Scripts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/scripting-in-perspective/perspective-property-change-scripts.md):
- [Perspective Event Scripts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/scripting-in-perspective/perspective-session-events-scripts.md): Perspective Event Scripts let you configure project level scripting that responds to key events in Perspective Sessions or on the Gateway. These sc...
- [Scripting in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/scripting-in-perspective.md): This section is designed to familiarize you with some of the basics of Python scripting in Perspective. Perspective scripting is particularly power...
- [Security in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/security-in-perspective.md): Security in Perspective is managed through [Identity Providers (IdP)](../../platform/security/identity-provider-authentication-strategy/identity-pr...
- [Creating and Using Custom Perspective Themes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles/creating-and-using-custom-perspective-themes.md): Themes help customize the look of components in your Perspective Sessions, acting as a foundation from which you can customize components even furt...
- [Changing the Theme from a Session](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles/perspective-built-in-themes/changing-the-theme-from-a-session.md): A theme can be set by directly writing to `session.props.theme` property. The property is writable from a session, so you can easily utilize compon...
- [Perspective Built-In Themes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles/perspective-built-in-themes.md): Perspective comes with several themes, providing initial styling to all components. The active theme in a session is determined by a [session prope...
- [How to Change Style on Hover](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles/style-classes/how-to-change-style-on-hover.md): Element states provide an opportunity to change the styling on a component when a user simply hovers the mouse cursor over a component. In this gui...
- [How to Change Text Size Based on Width](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles/style-classes/how-to-change-text-size-based-on-width.md): Since media queries react to viewport changes, we can use them to change the text size of a style class. Imagine a scenario where text needed to be...
- [How to Create a Flashing Component](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles/style-classes/how-to-create-a-flashing-component.md): In some cases you may want to have a label or other display component flash, standing out from other components on the screen. This can easily be a...
- [Style Classes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles/style-classes.md):
- [Styles](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/styles.md):
- [Time Zones in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/time-zones-in-perspective.md): A Perspective session can run with multiple different time zones simultaneously between the Gateway, Perspective session, and browser settings. Thi...
- [Docked Views](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/views-in-perspective/docked-views.md):
- [Embedded Views](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/views-in-perspective/embedded-views.md):
- [Popup Views](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/views-in-perspective/popup-views.md):
- [Self-Hiding Navigation Drawer](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/views-in-perspective/self-hiding-navigation-drawer.md): A navigation drawer is a special type of docked menu, usually appearing on the left side of a session. What makes a navigation drawer special is it...
- [Views in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/views-in-perspective.md):
- [Binding Property Path Reference](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/binding-property-path-reference.md): Perspective component bindings can reference the value of other properties. These references take the form of a relative path that leads to the ref...
- [Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective.md): Perspective allows for numerous types of bindings to allow for the dynamic updating of properties associated with Views or their child components.
- [Expression Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/expression-bindings-in-perspective.md):
- [Expression Structure Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/expression-structure-bindings-in-perspective.md):
- [HTTP Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/http-bindings-in-perspective.md):
- [MongoDB Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/mongodb-bindings-in-perspective.md): The MongoDB Cloud Connector module introduces a Perspective Binding type called MongoDB. The MongoDB binding follows the same format as the [Perspe...
- [Property Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/property-bindings-in-perspective.md):
- [Query Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/query-bindings-in-perspective.md):
- [Drop Configuration](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/tag-bindings-in-perspective/drop-configuration.md): On [view objects](appendix\components\perspective-components\perspective-view-object\perspective-view-object.md) in Perspective, the **dropConfig**...
- [Tag Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/tag-bindings-in-perspective.md): A Tag binding is a straight-forward binding type. It simply binds a property directly to a Tag Property (typically the value). This sets up a subsc...
- [Tag History Bindings in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/tag-history-bindings-in-perspective.md):
- [Expression Transform](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/transforms/expression-transform.md):
- [Format Transform](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/transforms/format-transform.md):
- [Map Transform](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/transforms/map-transform.md):
- [Script Transform](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/transforms/script-transform.md):
- [Transforms](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/bindings-in-perspective/transforms.md): Transforms offer a chance to alter the value returned from a binding. For example, you can bind a property to an integer value and use a transform ...
- [Component Events and Actions](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/component-events-and-actions.md):
- [Images and Icons in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/images-and-icons-in-perspective.md):
- [Localization in Perspective](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/localization-in-perspective.md): Localization in the Perspective module utilizes terms from Ignition's [Translation](appendix\expression-functions\translation\index.mdx) system. On...
- [Perspective Component Properties](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/perspective-component-properties.md):
- [Perspective Pipes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components/perspective-pipes.md): Pipes can be drawn within a coordinate container. These pipes can be used to visualize flow between separate objects on a view.
- [Working with Perspective Components](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/perspective/working-with-perspective-components.md):
- [Common Reporting Tasks](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/common-reporting-tasks.md): This section contains examples for items we've identified as common tasks: undertakings that many users are looking to utilize when first starting ...
- [Converting Legacy Reports](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/common-reporting-tasks/converting-legacy-reports.md): We encourage users to convert their reports to the new format if they feel they would benefit from the added functionality, but in doing so, it's i...
- [Labels with Embedded Barcodes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/common-reporting-tasks/labels-with-embedded-barcodes.md): Using labels with embedded barcodes is very common practice. Barcodes are typically used to print out mailing and shipping labels, and can be used ...
- [Tutorial - The Report Workflow](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/common-reporting-tasks/tutorial-the-report-workflow.md):
- [Alarm Journal Query](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/alarm-journal-query.md):
- [Basic SQL Query](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/basic-sql-query.md):
- [Named Query Data Source](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/named-query-data-source.md):
- [Nested Queries](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/nested-queries.md):
- [Report Data](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data.md):
- [Report Parameters](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/report-parameters.md):
- [Scripting Data Source](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/scripting-data-source.md):
- [SQL Query Data Source](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/sql-query-data-source.md):
- [Static CSV](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/static-csv.md):
- [Tag Calculation Query](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/tag-calculation-query.md):
- [Historian Query](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-data/tag-historian-query.md):
- [CrossTab and Simple Tables](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/crosstab-and-simple-tables.md): In the other sections of the Report Table, we talked about creating tables using the Table component, commonly referred to as Standard Tables. Stan...
- [Data Keys](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/data-keys.md): In the Reporting Module, we use **Data Keys** to pull values from data sources and show them on the report. In simple terms, Data Keys are placehol...
- [Keychain Expressions](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/data-keys/keychain-expressions.md):
- [Images in Reports](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/images-in-reports.md): You can enhance your reports by adding images, whether it's your corporate logo, or embedding icons in tables to help users find data quickly. Imag...
- [Getting Started with Report Charts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-charts/getting-started-with-report-charts.md): Report charts offer many functions and features, including various chart types. The best chart type for you to use depends on your data and how you...
- [Report Charts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-charts.md): * [Timeseries Chart](../../../../appendix/components/report-design-components/report-design-chart-palette/report-component-timeseries-chart/report-...
- [Report Design Tools](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-design-tools.md): Object layout is an important aspect in creating professional reports. The Reporting Module provides a host of intuitive tools and functions to hel...
- [Report Design](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design.md):
- [Charts Inside of Tables](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-table/charts-inside-of-tables.md): There are two common locations to place a chart inside a table:
- [Getting Started with the Report Table](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-table/getting-started-with-the-report-table.md): The [Report Table](ignition-modules/reporting/report-design/report-table/report-table.md) is another Reporting component, like report charts, that ...
- [Grouping Data Inside of Tables](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-table/grouping-data-inside-of-tables.md):
- [Report Tables](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-table.md): Tables are a major part of Ignition Reporting, taking provided data and displaying it in a structured way. The Reporting engine will automatically ...
- [Table Groups](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-table/table-groups.md):
- [Table Row Versioning](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-table/table-row-versioning.md):
- [Table Rows](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/report-table/table-rows.md):
- [Stroke and Fill Properties for Reports](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-design/stroke-and-fill-properties-for-reports.md): As you probably learned working with components, each component has its own unique properties. The [Report Design](ignition-modules\reporting\repor...
- [Report Designer Interface](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-designer-interface.md): Built to be intuitive and familiar, the Reporting workspace has a logical workflow which makes it easy for anyone to create meaningful reports. Bef...
- [Report Schedules](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-schedules.md):
- [Scheduling Actions](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting/report-schedules/scheduling-actions.md): Actions can be configured to run once the report has generated at the scheduled time. Each action has its own custom configuration interface to mak...
- [Reporting](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/reporting.md): The Ignition Reporting module makes creating professional reports easy with a rich library of tools including: images, graphs, tables, and basic sh...
- [Basic SECS/GEM Troubleshooting](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem/basic-secs-gem-troubleshooting.md): If you are unable to create an equipment connection after configuring the connection settings, verify that the **Active Port** and **Passive Port**...
- [SECS/GEM Messages](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem/sec-gem-messages.md): The SECS-II standard defines how information is exchanged between equipment and a host using messages. Messages are organized into categories calle...
- [SECS Definition Language (SDL) File](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem/secs-definition-language-sdl-file.md): The SECS Definition Language (SDL) file defines the structure and content of SECS messages for an equipment connection. All sent and received messa...
- [SECS/GEM Equipment Connections](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem/secs-gem-equipment-connections.md): Equipment connections can be configured using either Ethernet or serial communication, depending on what the equipment supports. Ethernet connectio...
- [Additional SECS/GEM Simulator Features](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem/secs-gem-simulator/additional-secs-gem-simulator-features.md): Each simulator is initialized with a set of status variables and equipment constants intended for demonstration and testing. These objects are acti...
- [SECS/GEM Simulator](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem/secs-gem-simulator.md): The SECS/GEM module includes the capability to add and configure equipment simulators. Equipment simulators include basic functionality and can han...
- [SECS/GEM](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem.md): :::note
- [Using the SECS/GEM Module](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/secs-gem/using-the-secs-gem-module.md): This page walks you through setting up a basic SECS/GEM environment using a simulator and a demo project. By the end of this tutorial, you will hav...
- [SFC Basics](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFC-basics.md):
- [Chart Scope and Variables](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFC-basics/chart-scope-and-variables.md):
- [SFC Designer Interface](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFC-designer-interface.md): The SFC module features a unique user interface within the Designer. To start, the Welcome tab allows you to create two types of charts: **Callable...
- [SFC Elements](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFC-elements.md): SFC Elements are the driving force of a chart. Each element has a purpose or dedicated functionality, and can be combined with other elements to pe...
- [SFCs In Action](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFCs-in-action.md): All charts have the same basic flow to them. Some have loops, jumps, or enclosing steps that include whole other charts, but the flow is always the...
- [Action Step Best Practices](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFCs-in-action/action-step-best-practices.md):
- [Monitoring and Debugging Charts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFCs-in-action/monitoring-and-debugging-charts.md):
- [Pause, Resume, and Cancel](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts/SFCs-in-action/pause-resume-and-cancel.md):
- [Sequential Function Charts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sequential-function-charts.md): A Sequential Function Chart (SFC) is a series of scripts that are defined in a single location, and then called in sequential order. Additional ele...
- [Hour and Event Meters](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/hour-and-event-meters.md):
- [Item Types](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/item-types.md): Items are the backbone of a Transaction Group. They represent a link between a source value (derived from either an OPC value or an expression) and...
- [SQL Bridge (Transaction Groups)](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups.md): **Transaction Groups** are the heart of the SQL Bridge module. They are execution engines that perform database tasks such as storing data historic...
- [Block Group](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/transaction-group-examples/block-group.md):
- [Recipe Group](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/transaction-group-examples/recipe-group.md): .
- [Transaction Group Examples](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/transaction-group-examples.md): * **Standard**: The heart of bi-directional data storage and management
- [Transaction Group Update Modes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/transaction-group-examples/transaction-group-update-modes.md): Transaction Groups are generally used to store OPC data into a database. Transaction Group Update Modes give users additional flexibility as to whe...
- [Trigger Options](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/transaction-group-examples/trigger-options.md):
- [Update or Insert Group](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/transaction-group-examples/update-or-insert-group.md):
- [Types of Groups](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/types-of-groups.md): The SQL Bridge Module provides four different types of Transaction Groups that you can use in your projects. Each of these different types of group...
- [Understanding Transaction Groups](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/sql-bridge-transaction-groups/understanding-transaction-groups.md):
- [Symbol Factory](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/symbol-factory.md): The Symbol Factory module is included with the Vision module or the Perspective module. Symbol Factory provides nearly 4,000 industrial high qualit...
- [Configuring Tag History](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/tag-historian/configuring-tag-history.md):
- [Historian](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/tag-historian.md): The Historian Core module lets you log and retrieve tag history using a variety of storage options. When history is enabled on a tag, its values ar...
- [DB Table Historian Provider](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/tag-historian/tag-history-providers/db-table-historian-provider.md):
- [Simulator Historian](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/tag-historian/tag-history-providers/historian-simulator.md):
- [Core Historian](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/tag-historian/tag-history-providers/internal-historian-questdb.md):
- [History Providers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/tag-historian/tag-history-providers.md): The Historian Core module supports multiple storage backends through a system of history providers. Each provider manages its own storage configura...
- [Binding Types in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision.md): Bindings are one of the most important concepts to understand when designing a project using the Vision module. It is primarily through Property bi...
- [Cell Update Bindings](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/cell-update-bindings.md):
- [Color Animation in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/color-animation-in-vision.md): Using color on components is an important part of creating effective HMIs. While static colors can help identify specific features on the screen, d...
- [DB Browse Bindings](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/db-browse-bindings.md):
- [Expression Binding in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/expression-binding-in-vision.md):
- [Function Bindings](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/function-bindings.md): The following example shows the default settings for the Function binding. Notice how each field has Tag and property binding buttons next to them....
- [Indirect Tag Bindings in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/indirect-tag-bindings-in-vision.md):
- [Named Query Bindings](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/named-query-bindings.md):
- [Property Bindings in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/property-bindings-in-vision.md):
- [SQL Query Bindings in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/sql-query-bindings-in-vision.md):
- [Tag Bindings in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/tag-bindings-in-vision.md):
- [Tag History Bindings in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/binding-types-in-vision/tag-history-bindings-in-vision.md):
- [Client Tags for Indirection](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/client-tags-for-indirection.md): [Vision Client Tags](ignition-modules\vision\vision-client-tags\vision-client-tags.md) can be used as a variable across all windows to indirectly p...
- [Common Tasks in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision.md): This section contains examples for items we've identified as "common" tasks: undertakings that many users are looking to utilize when first startin...
- [Component Animation](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/component-animation.md):
- [Custom Input Template](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/custom-input-template.md): Sometimes you may need to have text fields in your project for the user to input data. Rather than copying and pasting these text fields into each ...
- [Dropdown List Example](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/dropdown-list-example.md):
- [High Performance HMI Techniques](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/high-performance-hmitechniques.md): High performance HMI techniques and practices call for designs and displays which help the viewer make the best decision in the shortest amount of ...
- [Multi-Monitor Clients](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/multi-monitor-clients.md):
- [Open Dynamic Windows on Startup](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/open-dynamic-windows.md):
- [Tank Cutaway](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/common-tasks-in-vision/tank-cutaway.md):
- [Historian in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision.md): The [Historian](../../tag-historian/tag-historian.md) records tag data using configured history providers, which define how and where data is store...
- [Other Vision Trending Charts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/other-vision-trending-charts.md): Aside from the [Easy Chart](appendix/components/vision-components/charts/easy-chart/easy-chart.md) and [Classic Chart](appendix/components/vision-c...
- [Using the Classic Chart](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-classic-chart.md): The Customizer also lets you add additional X and Y axes. There are various types of axes and each works slightly differently. Lastly, you can conf...
- [Using the Tag Browse Tree for Charting](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/ad-hoc-charting.md): In the Designer, you can use a special built-in component called the Tag Browse Tree to create Ad Hoc Charts where you can pick and choose which pe...
- [Easy Chart - Axes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/easy-chart-axes.md): The [Easy Chart](appendix/components/vision-components/charts/easy-chart/easy-chart.md) supports the use of multiple axes for displaying data from ...
- [Easy Chart - Calculated Pens](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/easy-chart-calculated-pens.md): :::note This section assumes that Tags and Tag History have been configured
- [Easy Chart - Database Pens](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/easy-chart-database-pens.md): Database Pens are driven by a SQL query, so they are ideal to use when trending Transaction Group data. However, they can query for data in any con...
- [Easy Chart - Digital Offset](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/easy-chart-digital-offset.md): Digital pens often share the same subplot on the [Easy Chart](appendix/components/vision-components/charts/easy-chart/easy-chart.md) component. Whe...
- [Easy Chart - Pen Names and Groups](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/easy-chart-pen-names-and-groups.md): :::note This section assumes that Tags and Tag History have been configured
- [Easy Chart - Pen Renderer](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/easy-chart-pen-renderer.md): 
- [Easy Chart - Subplots](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/easy-chart-subplots.md): :::note This section assumes that Tags and Tag History have been configured
- [Indirect Easy Chart](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart/indirect-easy-chart.md): :::note This section assumes that Tags and Tag History have been configured
- [Using the Vision Easy Chart](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/historian-in-vision/using-the-vision-easy-chart.md): 
- [Local Client Fallback](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/local-client-fallback.md): Ignition Clients are fully dependent on being able to communicate with a Gateway. If Gateway communication is lost, the Client suspends operation w...
- [Client Event Scripts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision/client-event-scripts.md):
- [Component Events](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision/component-events.md):
- [Custom Component Methods](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision/custom-component-methods.md):
- [Extension Functions](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision/extension-functions.md):
- [Focus Manipulation](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision/focus-manipulation.md): 
- [Read a Cell from a Table](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision/read-a-cell-from-a-table.md): After data has been populated in a Table or Power Table component, it may be useful to read or extract a particular cell from the Table, especially...
- [Script Builders in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision/script-builders-in-vision.md):
- [Scripting in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/scripting-in-vision.md): A majority of the scripting that happens in Vision is either located on components and windows, or it manipulates component and window values. Many...
- [Component and Window Security](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/security-in-vision/component-and-window-security.md):
- [Security in Scripting](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/security-in-vision/security-in-scripting.md): While the Vision system has many options for securing individual components and clients, it is possible to have requirements that go further than t...
- [Security in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/security-in-vision.md): Security in Vision is managed through one of two authentication strategies, either the [Classic Authentication](platform/security/classic-authentic...
- [Vision Client Interface](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-client-interface.md): Vision Clients, launched in either windowed or fullscreen mode, contain a menubar above the configured project windows. By default, this menubar in...
- [Vision Client Tags](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-client-tags.md): Client Tags, as the name implies, are only available for use in Vision Clients. Their values are isolated to a Client runtime. All Clients will hav...
- [Vision Designer Interface](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-designer-interface.md): Learn more about the Vision workspace's user interface
- [Client Update Modes](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-project-properties/client-update-modes.md):
- [Setting Up Auto Login](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-project-properties/setting-up-auto-login.md): 1. In Designer, go to **Project > Properties**. The **Project Properties** window is displayed.
- [Using Touch Screen Mode](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-project-properties/using-touch-screen-mode.md):
- [Vision Project Properties](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-project-properties.md): There are a number of properties you can set for your Vision projects within the Designer. For example, there are properties for setting the Touch ...
- [Creating a Template](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-templates/create-a-template.md):
- [Template Indirection](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-templates/template-indirection.md): You can create templates that point indirectly to a set of Tags based on a simple parameter. This is very helpful when you have a large number of U...
- [Using the Template Canvas](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-templates/using-the-template-canvas.md):
- [Using the Template Repeater](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-templates/using-the-template-repeater.md):
- [Vision Templates](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-templates.md):
- [Navigation - Two Tier](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision/navigation-2-tier.md): Two Tier Navigation is similar to the [Tab Strip navigation](../navigation-tab-strip/navigation-tab-strip.md) strategy. It's good for small and reg...
- [Navigation - Forward and Back Buttons](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision/navigation-back-and-forward-buttons.md):
- [Navigation - Drill Down](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision/navigation-drill-down.md):
- [Navigation - Menubar](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision/navigation-menubar.md): You can set up a special menu within the Menubar that allows you to navigate throughout the project using the scripting functions. They can be simp...
- [Navigation - Retargeting](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision/navigation-retargeting.md):
- [Navigation Strategies in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision.md):
- [Navigation - Tab Strip](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision/navigation-tab-strip.md):
- [Navigation - Tree View](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/navigation-strategies-in-vision/navigation-tree-view.md):
- [Parameterized Popup Windows](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/popup-windows/parameterized-popup-windows.md):
- [Popup Windows](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/popup-windows.md): A popup window is typically a window that "floats" on top of the main window. It can be resized and moved around by the user, all while the main wi...
- [Vision Windows](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows.md): [Windows](appendix/components/vision-components/vision-window-object/vision-window-object.md) are the key to your HMI/SCADA application. A window i...
- [Window Types](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/vision-windows/window-types.md):
- [Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision.md): The Vision module is a tool for creating and maintaining an interactive, accurate Human-Machine Interface (HMI) for your site. Many other modules, ...
- [Comparison Charts](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/comparison-charts.md): This page provides an overview of the various comparison charts in Ignition, or charts that allow you to compare difference sets of data. Compariso...
- [Creating Vision Components](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/creating-vision-components.md):
- [Drawing Tools](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/drawing-tools.md):
- [Fill and Stroke](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/drawing-tools/fill-and-stroke.md):
- [Shape Geometry](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/drawing-tools/shape-geometry.md):
- [HTML in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/html-in-vision.md): HTML stands for HyperText Markup Language. It is commonly used to style text within web pages. The features that HTML brings to style web pages can...
- [Images and SVGs in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/images-and-svgs-in-vision.md):
- [Localization in Vision](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/localization-in-vision.md): Localization in the Vision module utilizes the terms in the [platform's Translation system](platform/localization-and-languages/localization-and-la...
- [Vision Component Customizers](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components/vision-component-customizer.md): The Vision module provides a number of customizers to configure components in ways that are more complex or detailed for basic properties.
- [Working with Vision Components](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/vision/working-with-vision-components.md): The Vision Module comes with a host of built-in components that you can select from for use in your project. One thing that you'll find when workin...
- [Building a Simple Web Server](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/web-dev/simple-web-server.md): This page demonstrates how to build and test a simple web server using the [Web Dev module](ignition-modules/web-dev/web-dev.md). You’ll create a s...
- [Web Dev](https://www.docs.inductiveautomation.com/docs/8.3/ignition-modules/web-dev.md): The [Web Dev module](../../getting-started/modules-overview/core-modules/webdev-module/webdev-module.md) enables you to directly program against th...
- [Ignition Platform](https://www.docs.inductiveautomation.com/docs/8.3/platform.md): The Ignition platform refers to the core installation of Ignition. It provides all the basic functionalities such as connecting to devices and data...
- [Advanced Deployments](https://www.docs.inductiveautomation.com/docs/8.3/platform/advanced-deployments.md): Several advanced deployment approaches are available for Ignition beyond those described within the [Installing and Upgrading](getting-started/inst...
- [Docker Image Examples](https://www.docs.inductiveautomation.com/docs/8.3/platform/advanced-deployments/docker-image/docker-image-examples.md): This page contains example run configurations for the Ignition Docker image to demonstrate best practices for specified scenarios.
- [Docker Image](https://www.docs.inductiveautomation.com/docs/8.3/platform/advanced-deployments/docker-image.md):
- [Kubernetes](https://www.docs.inductiveautomation.com/docs/8.3/platform/advanced-deployments/kubernetes.md): Users managing large-scale deployments may be interested in using the Ignition Container Image on Kubernetes. Kubernetes, or K8S, is an open source...
- [Alarm Journal](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/alarm-journal.md):
- [Alarming Schedules](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/alarming-schedules.md):
- [Alarming](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming.md): Alarming in Ignition is flexible and highly customizable to your needs. You can configure alarms with one alarm on a tag or multiple alarms on a ta...
- [Alarm Associated Data](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/configuring-alarms/alarm-associated-data.md): Associated data lets you attach additional context values to an alarm event. Every alarm in Ignition already carries built-in properties as it move...
- [Alarm Event Properties Reference](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/configuring-alarms/alarm-event-properties-reference.md): An alarm event is made up of many pieces of information. The state, value, time, and configuration data for the alarm are collectively known as the...
- [Alarms in UDTs](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/configuring-alarms/alarms-in-udts.md):
- [Configuring Alarms](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/configuring-alarms.md):
- [Dynamic Alarm Attributes](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/configuring-alarms/dynamic-alarm-attributes.md):
- [Exporting and Importing System Tag Configurations](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/configuring-alarms/exporting-and-importing-system-tag-alarms.md): There may be times when you want to export or import the configuration of a [System tag](platform\tags\types-of-tags\system-tags\system-tags.md). U...
- [Gateway General Alarm Properties](https://www.docs.inductiveautomation.com/docs/8.3/platform/alarming/gateway-general-alarm-properties.md): The alarm system has several settings available on the Gateway. These properties can be found under **Services > Alarming > Settings**.
- [Alarm Notification Auditing](https://www.docs.inductiveautomation.com/docs/8.3/platform/audit-log-and-profiles/alarm-notification-auditing.md):
- [Audit Log and Profiles](https://www.docs.inductiveautomation.com/docs/8.3/platform/audit-log-and-profiles.md): Ignition's built-in auditing system automatically records certain actions that occur in the system, such as a Tag writes or User Source authenticat...
- [Audit Log Displays](https://www.docs.inductiveautomation.com/docs/8.3/platform/audit-log-and-profiles/audit-log-display.md):
- [Auditing Actions Reference](https://www.docs.inductiveautomation.com/docs/8.3/platform/audit-log-and-profiles/auditing-action-reference.md): The auditing system in Ignition records actions originating from the Gateway, Perspective, and Vision projects. This page describes the actions log...
- [Connecting to Databases](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases.md): Many of the advanced features of Ignition, such as the Transaction Groups and Tags Historian require a connection to an external database and most ...
- [Connecting to IBM DB2](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-ibm-db2.md): In order to connect Ignition to IBM DB2 you must have a Translator, a Driver, and a Database Connection.
- [Connecting to MariaDB](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-mariadb.md):
- [Connecting to Microsoft Azure SQL](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-microsoft-azure-sql.md): Microsoft Azure SQL Server uses the same Java Database Connectivity (JDBC) driver as Microsoft SQL Server (MSSQL).
- [Connecting to Microsoft SQL Server Express](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-microsoft-sql-server-express.md): This guide helps you with any difficulties you may have in getting the correct settings and parameters when connecting Ignition to Microsoft SQL Se...
- [Connecting to MySQL](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-mysql.md): On this page we'll demonstrate how to connect Ignition to MySQL.
- [Connecting to Oracle Express](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-oracle-express.md): This page documents how to configure a database connection to an Oracle Express instance.
- [Connecting to PostgreSQL](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-postgresql.md): Connect Ignition to the PostgreSQL Database
- [Connecting to Snowflake](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-snowflake.md): In order to connect Ignition to Snowflake you must have a translator, a driver, and a database connection. The translator and driver only need to b...
- [Connecting to SQLite](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/connecting-to-sqlite.md): Connect Ignition to the PostreSQL Database
- [JDBC Driver and Database Translator Settings](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/jdbc-drivers-and-translators/jdbc-driver-and-database-translator-settings.md): This page details various JDBC driver and translator settings.
- [JDBC Drivers and Translators](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/connecting-to-databases/jdbc-drivers-and-translators.md): There are cases where drivers or translators may need modification.
- [Database Connections](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections.md): While connecting to a database is not required for basic status and control functionality, it can dramatically increase the possibilities that the ...
- [Installing Databases](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/installing-databases.md): A lot of additional functionality becomes simple or is only accessible when Ignition is connected to a database. Storing Historical data, storing n...
- [Installing IBM DB2](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/installing-databases/installing-ibm-db2.md): To Download IBM DB2 Community Edition
- [Installing Microsoft SQL Server Express](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/installing-databases/installing-microsoft-sql-server-express.md): To Download SQL Server Express
- [Installing MySQL](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/installing-databases/installing-mysql.md): To Install the MySQL Server and Workbench
- [Installing PostgreSQL](https://www.docs.inductiveautomation.com/docs/8.3/platform/database-connections/installing-databases/installing-postgresql.md): To Install the PostgreSQL Database
- [Designer Diagnostics](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-diagnostics.md): The Help menu in the Designer has a Diagnostics  option, which displays the Diagnostics window with tabs for six different troubleshoo...
- [Database Query Browser](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-tools/database-query-browser.md): The Database Query Browser is found in the tools menu and has a few basic parts to it. The first is the query text field at the top of the window w...
- [Designer Tools](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-tools.md): The Designer comes with many tools that allow you to manage and test various resources within a project. Each of the tools have their own interface...
- [Image Management Tool](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-tools/image-management-tool.md):
- [Keyboard Layouts](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-tools/keyboard-layouts.md): Keyboard layouts can be added, removed, and customized with the Keyboard Layout editor, which is available in the Tools menu of the Designer Vision...
- [Output Console](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-tools/output-console.md): The Output Console is a dockable panel that you can open via Tools > Script Console menu or the Ctrl-Shift-C keyboard shortcut. The Output Console ...
- [Script Console](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-tools/script-console.md):
- [General Designer Interface](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/designer-user-interface.md):
- [Designer](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer.md):
- [Find and Replace](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/find-and-replace.md):
- [Project Properties](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/project-properties.md): There are a number of properties you can set for your projects within the Designer, Vision Clients, and Perspective Sessions. For example, there ar...
- [Saving Projects](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/saving-projects.md): Once you created the Windows, Templates, Tags, Views, and anything else that goes into your project, you need to save your work. Saving your progre...
- [Windows, Linux, and Mac Keyboard Shortcuts](https://www.docs.inductiveautomation.com/docs/8.3/platform/designer/windows-linux-and-mac-keyboard-shortcuts.md): | Action | Windows/Linux Keystrokes | MacOS Keystrokes |
- [Expression Language and Syntax](https://www.docs.inductiveautomation.com/docs/8.3/platform/expression-language-and-syntax.md): Expressions are also used for bindings in both Vision and Perspective. See the [Expression Bindings in Vision](../../ignition-modules/vision/bindin...
- [Gateway Backup and Restore](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/gateway-backup-and-restore.md):
- [Connections](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/connections.md): The Connections section of the Gateway contains information regarding Gateway connections to external systems. The list of systems displayed under ...
- [Execution](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics/diagnostics-execution.md): The Execution page reports the status of all tasks that your Gateway runs on a schedule. Shared and Private tabs are found at the top of the page t...
- [Logs](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics/diagnostics-logs.md): One of the most important troubleshooting tools of the Gateway Webpage is the Logs page. This console shows errors caused by Gateway events like da...
- [Wrapper Logs](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics/diagnostics-logs/wrapper-logs.md): Wrapper logs are a set of plain text log files located inside the installation directory on the computer where Ignition Gateway is installed. The e...
- [Metrics Dashboard](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics/diagnostics-metrics-dashboard.md): The Metrics Dashboard allows users to visualize a variety of metrics on their own customizable dashboards. Users may browse and search for any regi...
- [Scripts](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics/diagnostics-scripts.md): The Running Scripts page provides a real-time view of all actively running Gateway scripts and includes tools to manage them, such as terminating a...
- [Threads](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics/diagnostics-threads.md): The Threads page displays a snapshot of information about Gateway’s execution threads. This information may be important when troubleshooting certa...
- [Diagnostics](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics.md): The Diagnostics section displays information regarding the internal Gateway system, while giving you the ability to drill down into specific system...
- [Performance](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/diagnostics/system-performance.md): The System Performance page displays information on the resource usage of the Gateway. Select **Diagnostics** > **Performance** to access the Perfo...
- [Designer - Gateway Section](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/home/designer.md): The Designer section of the Gateway includes a Download and Connections page for easy access to general Designer session information and the abilit...
- [Home](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/home.md): The first time you go to the Gateway Homepage, it shows several steps to help you get started. Once you're up and running, the Home section provide...
- [Perspective - Gateway Section](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/home/perspective.md): The Perspective section of the Gateway includes Launch, Download, Sessions, and Brand Customization pages for easy access to basic Perspective info...
- [Sessions](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/home/perspective/sessions.md): 
- [Clients](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/home/vision/vision-clients.md): The Vision Clients page shows information regarding currently opened Clients, such as the address of the Client. On your Gateway, navigate to **Hom...
- [Vision - Gateway Section](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/home/vision.md): The Vision section of the Gateway includes Launch, Download, and Clients pages for easy access to basic project information and the ability to down...
- [Email Settings](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/network/email-settings.md): Once your Email Profile is set up, you only need to reference the name of the connection and Ignition will take care of the rest.
- [Network](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/network.md): There are three sections under the Overview option for further Gateway Network configuration:
- [Secure Communication (SSL/TLS)](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/network/web-server-settings/secure-communication-ssl-tls.md):
- [Web Server Settings](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/network/web-server-settings.md): The Web Server Settings page is for configuring the HTTP and HTTPS ports, enabling SSL/TLS, redirecting traffic through a known address, and specif...
- [Gateway Deployment Mode Examples](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/platform/gateway-deployment-modes/gateway-deployment-mode-examples.md): 1. Navigate to the Modes page by going to **Platform** > **System** > **Modes**.
- [Gateway Deployment Modes](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/platform/gateway-deployment-modes.md):
- [Gateway Settings](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/platform/gateway-settings.md): After you [launch the Gateway](platform\gateway\gateway.md), you can define the high-level settings that apply to the entire Gateway by going to **...
- [Platform](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/platform.md): The Platform tab includes information regarding the Gateway [system](#system) and [security](#security). This includes system pages for Gateway con...
- [Services](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface/services.md): The Services Overview page displays a status summary for all the configured connections, including the number of services currently configured, err...
- [Web Interface](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway/web-interface.md):
- [Gateway Network Connections](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway-network/connections-gateway-network.md): This page gives a general overview of the Gateway Network Connections page for Outgoing Connections, Incoming Connections, and Remote Gateways on G...
- [Remote Gateways and Connections Details](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway-network/connections-gateway-network/remote-gateways-and-connections-details.md):
- [Gateway Network Certificates and SSL](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway-network/gateway-network-certificates-and-ssl.md): When a remote machine establishes an incoming connection, its server name is transmitted and appears in the Gateway Name field under **Network** > ...
- [Gateway Network Diagram](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway-network/gateway-network-diagram.md): 
- [Gateway Network](https://www.docs.inductiveautomation.com/docs/8.3/platform/gateway-network.md):
- [Database Considerations](https://www.docs.inductiveautomation.com/docs/8.3/platform/ignition-redundancy/database-considerations.md): Given that many parts of the Ignition system interact with the database, it's important to give some thought as to how it will be used when redunda...
- [Ignition Redundancy](https://www.docs.inductiveautomation.com/docs/8.3/platform/ignition-redundancy.md):
- [Redundant Licensing](https://www.docs.inductiveautomation.com/docs/8.3/platform/ignition-redundancy/redundant-licensing.md):
- [Setting Up Redundancy](https://www.docs.inductiveautomation.com/docs/8.3/platform/ignition-redundancy/setting-up-redundancy.md):
- [Emergency Activation Mode](https://www.docs.inductiveautomation.com/docs/8.3/platform/licensing-and-activation/emergency-activation.md): 
- [Leased Licensing](https://www.docs.inductiveautomation.com/docs/8.3/platform/licensing-and-activation/leased-licensing.md):
- [Licensing and Activation](https://www.docs.inductiveautomation.com/docs/8.3/platform/licensing-and-activation.md):
- [Transfer a License Key Between Two Gateways](https://www.docs.inductiveautomation.com/docs/8.3/platform/licensing-and-activation/transfer-a-license-key-between-two-gateways.md): Transferring your license key combines two parts: the unactivation steps and activation steps, which are covered on the [Licensing and Activation](...
- [Creating Translation Lists](https://www.docs.inductiveautomation.com/docs/8.3/platform/localization-and-languages/creating-translation-lists.md):
- [Locale Formats and Language Tags](https://www.docs.inductiveautomation.com/docs/8.3/platform/localization-and-languages/locale-formats.md): Explains how Ignition represents locales as strings, the difference between the legacy underscore format and BCP-47 language tags, and which format...
- [Localization and Languages](https://www.docs.inductiveautomation.com/docs/8.3/platform/localization-and-languages.md): Localization lets you display projects in multiple languages. Translations are stored in the Gateway and can be used in Perspective sessions, Visio...
- [Localization Keys](https://www.docs.inductiveautomation.com/docs/8.3/platform/localization-and-languages/localization-best-practices.md): Ignition's localization features allow you to present your project in multiple languages without duplicating views or windows. This page outlines b...
- [Switching the Current Language](https://www.docs.inductiveautomation.com/docs/8.3/platform/localization-and-languages/switching-the-current-language.md): * Expression Function
- [Project Export and Import](https://www.docs.inductiveautomation.com/docs/8.3/platform/projects/project-export-and-import.md):
- [Project Inheritance](https://www.docs.inductiveautomation.com/docs/8.3/platform/projects/project-inheritance.md):
- [Project Settings](https://www.docs.inductiveautomation.com/docs/8.3/platform/projects/project-settings.md): When you create a new project, you'll have the options to configure most of the project settings. Projects can be created from the Projects page on...
- [Project Templates](https://www.docs.inductiveautomation.com/docs/8.3/platform/projects/project-templates.md): When you [launch the Designer](../../../launchers-and-workstation/designer-launcher/designer-launcher.md), you will be presented with the Open/Crea...
- [Projects](https://www.docs.inductiveautomation.com/docs/8.3/platform/projects.md): Projects are predominantly used to create the screens that your users can interact with, the visualization part of Ignition. Here you can create an...
- [Basic Python Troubleshooting](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/basic-python-troubleshooting.md): When learning how to code in Python, most Ignition users tend to place most of their learning efforts on memorizing syntax or other aspects of the ...
- [Reading Error Messages](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/basic-python-troubleshooting/reading-error-messages.md): When an error occurs in the execution of a script, an error message box will pop up. The popup box appears in front of any open Designer windows, a...
- [Scripting Vs. SQL Vs. Expressions](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/basic-python-troubleshooting/scripting-vs-sql-vs-expressions.md): ```js title="Expression Language - Comment"
- [Troubleshooting - Nothing Happened](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/basic-python-troubleshooting/troubleshooting-nothing-happened.md): When a script doesn't perform to expectations and doesn't throw an exception, it can suggest a problem with the script's workflow. This page descri...
- [Troubleshooting Workflow](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/basic-python-troubleshooting/troubleshooting-workflow.md): Troubleshooting a script is an iterative process. Since the script stops executing at the first error, we won't see if there are any other errors o...
- [JSON Format](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/json-format.md): * Data is in name/value pairs.
- [Built-In Functions](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/built-in-functions.md): Functions are invoked by using their name followed by an argument list surrounded in parentheses. If there are no arguments, you still need an open...
- [Conditions and Loops](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/conditions-and-loops.md):
- [Error Handling](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/error-handling.md): The concept of error handling is recognizing when an error might occur in a block of code, and instead of throwing the error, handling it gracefull...
- [Libraries](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/libraries.md): ```python title="Pseudocode - Reading a Tag Value"
- [Python Scripting](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting.md): This section is a short tutorial specifically for python, which should help get you started. It goes over all of the core concepts you will need fo...
- [User Defined Functions](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/user-defined-functions.md):
- [Datasets](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/variables-datatypes-and-objects/datasets.md):
- [Dates](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/variables-datatypes-and-objects/dates.md): Python has some [built-in libraries](../libraries.md#python-libraries) to create and manipulate dates and times. However, most users find both Igni...
- [Dictionaries](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/variables-datatypes-and-objects/dictionaries.md): A Dictionary is a mapping object. Where sequences are indexed with a numeric index value, dictionaries are indexed using keys. These keys then have...
- [Lists and Tuples](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/python-scripting/variables-datatypes-and-objects/lists-and-tuples.md):
- [Parsing XML with Java Libraries](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-examples/parsing-xml-with-the-etree-library.md): :::caution XML Document Security
- [Reading and Writing to Tags](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-examples/reading-and-writing-to-tags.md): In many cases, the binding system is the most appropriate way to display a Tag value on the screen. However, you may wish to access a Tag's value i...
- [Scripting Examples](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-examples.md): This section contains examples for items we've identified as "common" tasks: undertakings that many users are looking to utilize when first startin...
- [Gateway Event Scripts](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition/gateway-event-scripts.md): Note that even though Gateway Event Scripts run on the Gateway, they're still considered a project resource and are stored as readable PY files. Pr...
- [Getting Started with Scripting in Ignition](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition/getting-started-with-scripting.md): The best way to get started with scripting in Ignition is to write some very simple scripts and print them within Ignition. Let's take the phrase, ...
- [Project Library](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition/project-library.md): Scripts under the Project Library are a project-based resource that allows user created Python scripts to be configured. Objects and functions crea...
- [Script Logging and Print Statement Output Reference](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition/script-logging-print-statement-output.md): Just as each script has its own events based on location that trigger the script to run, output logging is also dependent on where the script is ex...
- [Scripting in Ignition](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition.md):
- [HTTP Methods](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition/web-services-suds-and-rest/http-methods.md): ```py title="Endpoint URL Template"
- [SUDS - Library Overview](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition/web-services-suds-and-rest/suds-library-overview.md): :::caution Disclaimer
- [Web Services, SUDS, and REST](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting/scripting-in-ignition/web-services-suds-and-rest.md): * HTTP methods, such as GET and POST, are called using the built-in system function [system.net.httpClient](appendix\scripting-functions\system-net...
- [Scripting](https://www.docs.inductiveautomation.com/docs/8.3/platform/scripting.md): Most of the time when we talk about "scripting" in Ignition we are talking about Python scripting, or writing code in the Python language. Python i...
- [API Keys](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/api-keys.md): An API Key is a unique identifier used to authenticate and authorize access to a system's resources without requiring a username and password for e...
- [Active Directory Authentication](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/active-directory-authentication.md): The Active Directory Authentication profile uses Microsoft's Active Directory over **LDAP** (Lightweight Directory Access Protocol) to store all th...
- [AD Database Hybrid](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/ad-database-hybrid.md):
- [AD Internal Hybrid](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/ad-internal-hybrid.md):
- [Classic Authentication Strategy](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy.md): The Classic Authentication strategy authenticates users against a User Source. Both the Designer and Vision Client can authenticate users with this...
- [Database Authentication](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/database-authentication.md):
- [Fallback Cache Authentication](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/fallback-cache-authentication.md): This User Source was developed specifically for a system that is using [Local Vision Client Fallback](ignition-modules\vision\local-client-fallback...
- [Internal Authentication](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/internal-authentication.md):
- [Managing Users and Roles](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/managing-users-and-roles.md): Security is based on the roles that are assigned to specific users. Roles do not have any structure or hierarchy by default, but it can be created....
- [Verify a User on a User Source](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/classic-authentication-strategy/verify-a-user-on-a-user-source.md): You can verify that a user exists in a given [User Source](platform\security\classic-authentication-strategy\classic-authentication-strategy.md), i...
- [Gateway General Security Settings](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/gateway-general-security-settings.md):
- [Configuring Identity Providers](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/configuring-identity-providers.md): Before configuring an Identity Provider on the Ignition Gateway, it must first be registered as an Identity Provider Client. Your Identity Provider...
- [OpenID Connect 1.0 Example](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/configuring-identity-providers/openid-connect-1-example.md): This section provides an example of how to connect an Identity Provider that is using the OpenID Connect 1.0 protocol. This example uses the Okta ...
- [SAML Example](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/configuring-identity-providers/saml-example.md): This section provides an example of how to connect an Identity Provider that is using the SAML protocol. This example uses the Okta IdP service. Yo...
- [User Attribute Mapping](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/configuring-identity-providers/user-attribute-mapping.md): The User Attribute Mapping page allows you to map information in the Identity Providers (IdP) response document to easily understandable properties...
- [Identity Provider Authentication Strategy](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy.md): An Identity Provider (IdP) offers a way for users to log in to Ignition using credentials stored outside of Ignition. An IdP creates, maintains, an...
- [Security Level Rules](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/security-level-rules.md):
- [Security Levels](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/security-levels.md):
- [Test Login and Logout](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/test-login-and-logout.md): On the Identity Providers screen you can test a username and password combination against an Identity Provider (IdP).
- [Troubleshooting Identity Providers](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/troubleshooting-identity-providers.md): This Troubleshooting section has a compilation of examples to help you diagnose and troubleshoot issues with configuring IdPs.
- [User Grants](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/identity-provider-authentication-strategy/user-grants.md):
- [OAuth 2.0 Clients](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/oauth-2-clients.md): **OAuth 2.0** is an authorization standard that is developed by [IETF OAuth Working Group](https://www.ietf.org/mailman/listinfo/oauth). Unlike bas...
- [Project Security in the Designer](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/project-security-in-the-designer.md): When several users are all working on the same project, managing changes to the project can become cumbersome. By default, all users with Designer ...
- [Secrets Management Key CLI Tool](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/secrets-management/secrets-management-key-cli-tool.md): The built-in scripts included on this page are available with the Secrets Management Key CLI tool that is included with each Ignition installation ...
- [Secrets Management](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/secrets-management.md):
- [Security Certificates](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/security-certificates.md): A security certificate, also known as a digital certificate, is used to provide trust between connections. Trusted certificates establish the ident...
- [Security Zones](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/security-zones.md):
- [Security](https://www.docs.inductiveautomation.com/docs/8.3/platform/security.md): Security options in Ignition provide many ways to safeguard access to your data and applications. You control not only who accesses your systems, b...
- [Service Security Policies](https://www.docs.inductiveautomation.com/docs/8.3/platform/security/service-security.md): Policies can be defined for each Security Zone. [Security Zones](platform/security/security-zones/security-zones.md) and their policies can be foun...
- [Basic SQL Troubleshooting](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/basic-sql-troubleshooting.md): Learning when something is wrong with your database queries and learning how to resolve the problem is key to getting the best possible use out of ...
- [Slow Queries](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/basic-sql-troubleshooting/slow-queries.md): Slow running queries can be a big problem. Not only can data take a long time to display on the screen, but it can end up slowing down the whole cl...
- [SQL Query Volume Optimization](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/basic-sql-troubleshooting/sql-query-volume-optimization.md): Your company may also have a database administrator who would manage the database system for your company and would be familiar with figuring out t...
- [Common SQL Tasks](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks.md): This section contains examples for items we identified as "common" tasks. When first starting out with [SQL in Ignition](platform\sql-in-ignition\s...
- [Editing Multi-Selected Rows from a Table](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks/editing-multi-selected-rows-from-a-table.md): |id|machine_name|area_number|
- [Filter Rows in a Table](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks/filter-rows-in-a-table.md): We can then use the value of the Dropdown to drive the query. When you select a different option from the Dropdown component the binding gets re-ev...
- [Inserting Data into a Database](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks/inserting-data-into-a-database.md): A common way to insert information into a database is to run a script after a user presses a Button component that will collect data and execute a ...
- [Refreshing a SQL Query](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks/refreshing-a-sql-query.md): ```python title="Pseudocode - Refreshing a Table after an Edit"
- [Simple Database Editor](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks/simple-database-editor.md): The table is called **trucks**, and it has four columns.
- [Storing Files in a Database](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks/storing-files-in-a-database.md): Ignition can store different types of files into a database by storing the raw file bytes into a special database column. Ignition can also pull th...
- [Updating the Database through the Power Table](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/common-sql-tasks/updating-the-database-through-the-power-table.md): Suppose your database had a Table like this:
- [Named Queries](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/named-queries.md):
- [Named Query Caching](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/named-queries/named-query-caching.md): Named Query caching is disabled by default, but can be enabled on the **Settings** section of each Named Query. If caching is enabled, the spinner ...
- [Named Query Conversions](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/named-queries/named-query-conversions.md): 
- [Named Query Parameters](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/named-queries/named-query-parameters.md): Parameters allow you to make Named Queries dynamic. They act as placeholders you can pass values into when requesting the query to execute. Other r...
- [Named Query Workspace](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/named-queries/named-query-workspace.md): Named Queries have a dedicated workspace inside of the Project Section of the Designer. This workspace allows for the creation and testing of Named...
- [Using Named Queries - Example](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/named-queries/using-named-queries-example.md): We are going to be querying a table in the database that holds information about products stored in storage bays. The database table is named "cont...
- [Queries in Scripting](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/queries-in-scripting.md): Additionally, Named Queries are incredibly easy to call from a script, since you only need to know their name, and don't have to bother with SQL sy...
- [Query Builder](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/query-builder.md): 
- [SQL in Ignition](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition.md): 
- [SQL Common Functions](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/writing-sql-queries/sql-common-functions.md): Functions are available in most SQL databases, and can provide some helpful utility to any queries you may be calling in Ignition.
- [SQL Select Statements](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/writing-sql-queries/sql-select-statements.md): While the SELECT command in its basic form can be very simple to use, the SELECT statement can be used with other statements or in certain ways tha...
- [SQL Stored Procedures](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/writing-sql-queries/sql-stored-procedures.md): For the uninitiated, Stored Procedures are a series of predefined SQL statements that are configured and stored in a database. They can be easily c...
- [SQL Table Joins](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/writing-sql-queries/sql-table-joins.md): Joins may look imposing at first, but they are simply SELECT statements that utilize columns from multiple tables.
- [SQL Where Clauses](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/writing-sql-queries/sql-where-clauses.md): - In conjunction with a SELECT statement to filter the number of rows returned
- [Writing SQL Queries](https://www.docs.inductiveautomation.com/docs/8.3/platform/sql-in-ignition/writing-sql-queries.md): :::info
- [Configuring Store and Forward](https://www.docs.inductiveautomation.com/docs/8.3/platform/store-and-forward/configuring-store-and-forward.md):
- [Controlling Quarantine Data](https://www.docs.inductiveautomation.com/docs/8.3/platform/store-and-forward/controlling-quarantine-data.md):
- [Store and Forward](https://www.docs.inductiveautomation.com/docs/8.3/platform/store-and-forward.md):
- [Using Store and Forward](https://www.docs.inductiveautomation.com/docs/8.3/platform/store-and-forward/using-store-and-forward.md):
- [Creating Tags](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/creating-tags.md): Tags are created in the Designer in one of two ways; either using the Connected Devices window or creating tags manually in the Tag Browser.
- [Exporting and Importing Tags](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/exporting-and-importing-tags.md):
- [Quality Codes and Overlays](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/quality-codes-and-overlays.md):
- [Tag Browser](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-browser.md):
- [Tag Data Types](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-data-types.md): This page describes the data types that can be applied to standard tags.
- [Tag Diagnostics](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-diagnostics.md):
- [Tag Editor](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-editor.md): The Tag Editor is a robust interface that contains all the properties that can be configured for tags. In the Tag Editor, you set the tag's name, v...
- [Tag Event Scripts](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-event-scripts.md):
- [Direct Tag Group Example](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-groups/direct-tag-group-example.md): You created a new Direct 5 Second Tag Group and added your Tags. Just make sure you want to poll the 5 second values all the time (24/7) when you u...
- [Driven Tag Group Examples](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-groups/driven-tag-group-example.md): 
- [Leased Tag Group Example](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-groups/leased-tag-group-example.md): 1. In the **Tag Browser**, click on the **Tag Group**  icon to open the **Tag Group Editor**.
- [Tag Groups](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-groups.md):
- [Tag Paths](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-paths.md): Tags and their properties can be referenced by a string-based path in many areas of Ignition, such as [expressions](ignition-modules\perspective\wo...
- [Wildcards in Tag Paths](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-paths/wildcards-in-tag-paths.md):
- [Tag Alarm Properties](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-properties/tag-alarm-properties.md): The table in this section provides a description of alarm properties. The descriptions of these properties can also be viewed in the Tag Editor > A...
- [Tag Properties](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-properties.md): Tags are points of data and may have static values or dynamic values that come from an OPC address, an Expression, or a SQL query. The values can b...
- [Tag Scaling Properties](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-properties/tag-scaling-properties.md):
- [Tag Security Properties](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-properties/tag-security-properties.md): Tag security is often the best way to configure security for data access. By defining security on a Tag, you affect the Tag across wherever it is u...
- [Tag Providers](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-providers.md): At the highest level of tag configuration is the Tag Provider. A provider is a tag database (a collection of tags) and a name. An Ignition Gateway ...
- [Tag Report Tool](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/tag-report-tool.md): The Tag Report Tool allows users to search for tags by multiple criteria, including **Tag Path**, **Quality**, **Type**, **Traits**, and values on ...
- [Tags](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags.md): Tags provide a consistent data model throughout Ignition, and offer the easiest way to get up and running creating realtime status and control syst...
- [System Tags](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/types-of-tags/system-tags.md):
- [Types of Tags](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/types-of-tags.md): There are many different types of tags in Ignition: standard tags, [System Tags](platform\tags\types-of-tags\system-tags\system-tags.md), and [Visi...
- [UDT Inheritance](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/user-defined-types-udts/udt-inheritance.md):
- [UDT Multi-Instance Wizard](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/user-defined-types-udts/udt-multi-instance-wizard.md):
- [UDT Nesting](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/user-defined-types-udts/udt-nesting.md):
- [UDT Parameters](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/user-defined-types-udts/udt-parameters.md): Parameters effectively act as variables that can be referenced by properties on members. A common use case for a parameters in UDTs is to make the ...
- [User Defined Types - UDTs](https://www.docs.inductiveautomation.com/docs/8.3/platform/tags/user-defined-types-udts.md):
- [Appendix](https://www.docs.inductiveautomation.com/docs/8.3/appendix.md): The appendix is your quick reference to all the Components, Expression Functions, and Scripting Functions in Ignition. Each item has a definition, ...
- [Components](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components.md): Components are what give you flexibility in designing HMI and SCADA that reflect your company's design and your site's layout. Components are the w...
- [Perspective - Chart Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette.md): The following is a complete list of Chart components that give you various options for displaying data, and a link pointing to a page containing th...
- [Perspective - Chart Range Selector](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-chart-range-selector.md): The Chart Range Selector component is a small recreation of a chart that operators can use to select a time range based on seeing the existing data.
- [Perspective - Gauge](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-gauge.md): The Gauge component in Perspective provides a way to show realtime values in a range as they change.
- [Perspective - Pie Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-pie-chart.md): A Pie Chart displays a list of named items, each of which has a value that is part of a total.
- [Perspective - Power Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-power-chart.md): The Power Chart collects and displays data based on the pens that have been configured on the chart.
- [Perspective - Simple Gauge](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-simple-gauge.md): The Simple Gauge component in Perspective provides a way to show realtime values in a range as they change.
- [Perspective - Time Series Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-time-series-chart.md): The Time Series component provides an efficient way to visualize data from a variety of different data sources as chart data.
- [Perspective - XY Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-xy-chart.md): The XY Chart displays data trends.
- [XY Chart Example - Bar Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-xy-chart/xy-chart-example-bar-chart.md): This example demonstrates how to configure a bar chart using the XY Chart component.
- [XY Chart Example - Candlestick Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-xy-chart/xy-chart-example-candlestick.md): This example demonstrates how to configure a candlestick chart. The candlestick chart needs five keys per entry on the chart: a key to represent th...
- [XY Chart Example - Gantt Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-xy-chart/xy-chart-example-gantt-chart.md): In addition to basic data plotting, an XY Chart can be used to plot horizontal bar across different lanes, in this fashion:
- [XY Chart Example - Heat Map](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-xy-chart/xy-chart-example-heat-map.md): This example demonstrates how to configure a Heatmap, where the value of each cross axis is represented as a color along a gradient. This style of ...
- [XY Chart Example - Line Chart Target Area](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-chart-palette/perspective-xy-chart/xy-chart-example-line-chart-target-area.md): This example demonstrates how to utilize the **line.open** property to create a target zone. Target zones can be used to represent acceptable value...
- [Perspective Components](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components.md):
- [Perspective - Breakpoint Container Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-breakpoint-container/perspective-breakpoint-container-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Breakpoint Container](perspective-breakpoi...
- [Perspective - Breakpoint Container](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-breakpoint-container.md): The Breakpoint container consists of a single breakpoint, with two child views.
- [Perspective - Column Container Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-column-container/perspective-column-container-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Column Container](perspective-column-conta...
- [Perspective - Column Container](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-column-container.md): The Column Container is a 12 column grid layout, where components can be organized into columns which alter their layout depending on screen viewpo...
- [Perspective - Container Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette.md): The following is a complete list of container components, and a link pointing to a page with the component's description, properties, and an exampl...
- [Perspective - Coordinate Container Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-coordinate-container/perspective-coordinate-container-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Coordinate Container](perspective-coordina...
- [Perspective - Coordinate Container](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-coordinate-container.md): The Coordinate Container makes a component's size and location relative to its parent's size and location.
- [Flex Container User Interface](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-flex-container/flex-container-user-interface.md): When a [Flex container](perspective-flex-container.md) is deep selected, there is a Graphical User Interface (GUI) at the top of the Perspective Pr...
- [Perspective - Flex Container Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-flex-container/perspective-flex-container-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Flex Container](perspective-flex-container...
- [Perspective - Flex Container](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-flex-container.md): The Flex container provides an efficient way to lay out, align, and distribute space among components.
- [Perspective - Split Container Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-split-container/perspective-split-container-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Split Container](perspective-split-contain...
- [Perspective - Split Container](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-split-container.md): The Split container holds two children separated by a draggable split that allows the user to resize the two children during the runtime.
- [Perspective - Tab Container Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-tab-container/perspective-tab-container-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Tab Container](perspective-tab-container.m...
- [Perspective - Tab Container](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-container-palette/perspective-tab-container.md): The Tab container uses tabs as navigation buttons arranged together with the selected tab highlighted.
- [Perspective - Alarm Journal Table Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-alarm-journal-table/perspective-alarm-journal-table-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Alarm Journal Table](perspective-alarm-jou...
- [Perspective - Alarm Journal Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-alarm-journal-table.md): The Perspective Alarm Journal Table displays the history of the alarm system.
- [Perspective - Alarm Status Table Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-alarm-status-table/perspective-alarm-status-table-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [Alarm Status Table](perspective-alarm-stat...
- [Perspective - Alarm Status Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-alarm-status-table.md): The Alarm Status Table allows you to view currently active alarm events in the system
- [How To Restrict Acknowledgement on the Perspective Alarm Status Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-alarm-status-table/restrict-acknowledgement.md): You can restrict specific users or roles from Acknowledging alarms by setting the **enableAcknowledge** property in the Property Editor to **false*...
- [Perspective - Audio Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-audio/perspective-audio-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [Audio](appendix/components/perspective-com...
- [Perspective - Audio](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-audio.md): An audio component that Designers can use to play and pause sound clips in the browser.
- [Perspective - Barcode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-barcode.md): The Barcode component enables you to display text as a barcode.
- [Perspective - Cylindrical Tank](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-cylindrical-tank.md): A component that looks like a 3D cylindrical tank with some liquid inside.
- [Configuring a Dashboard](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-dashboard/configuring-a-dashboard.md): The Dashboard exposes widgets to end users in a [Perspective Session](ignition-modules/perspective/perspective-sessions/perspective-sessions.md) so...
- [Perspective - Dashboard](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-dashboard.md): The Dashboard component exposes layout capabilities to end users in a Perspective session.
- [Perspective - Display Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette.md): Perspective offers a variety of components that display static and dynamic information.
- [Perspective - Drawing Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-drawing/perspective-drawing-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [Drawing](appendix\components\perspective-c...
- [Perspective - Drawing](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-drawing.md): A component that allows users to embed, create, and modify vector graphics within the Designer, integrating seamlessly with Perspective projects.
- [Perspective - Equipment Schedule Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-equipment-schedule/perspective-equipment-schedule-scripting.md): The [Perspective Event Types Reference](appendix/reference-pages/perspective-event-types-reference.md) page describes all the possible component ev...
- [Perspective - Equipment Schedule](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-equipment-schedule.md): The Equipment Schedule component is a mix between the Status Chart, Gantt Chart, and Calendar components.
- [Perspective - Google Map Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-google-map/perspective-google-map-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Google Map](perspective-google-map.md) com...
- [Perspective - Google Map](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-google-map.md): The Google Map component provides a new interactive map option to the Map component.
- [Perspective - Icon](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-icon.md): The Icon component provides access to a collection of Scalable Vector Graphic (SVG) images.
- [Perspective - Image](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-image.md): The Image component displays either vector or raster format images, such as a jpeg, gif, png, or svg.
- [Perspective - Inline Frame](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-inline-frame.md): The Inline Frame component enables you to display a webpage within the component.
- [Perspective - Label](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-label.md): The Label component displays text and can be customized.
- [Perspective - LED Display](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-led-display.md): The LED Display is a stylized numeric and/or alphanumeric label.
- [Perspective - Linear Scale](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-linear-scale.md): The Linear Scale component displays a series of tick marks and labels.
- [Perspective - Adding GeoJSON Shapes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-map/perspective-map-adding-geojson-shapes.md): 
- [Perspective - Custom Controls Example](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-map/perspective-map-custom-controls-example.md): In this example, we'll set up three custom controls on a map component. The controls will be icons in the top right corner. When a user clicks on t...
- [Perspective - Map Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-map/perspective-map-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Map](perspective-map.md) component.
- [Perspective - Map](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-map.md): The Map component provides a mobile-friendly interactive map.
- [Perspective - Markdown](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-markdown.md): The Markdown component allows users to format any type of text so it is publishable as plain text.
- [Perspective - Moving Analog Indicator](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-moving-analog-indicator.md): The Moving Analog Indicator displays an analog value in context with other information.
- [Perspective - PDF Viewer Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-pdf-viewer/perspective-pdf-viewer-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [PDF Viewer](perspective-pdf-viewer.md) com...
- [Perspective - PDF Viewer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-pdf-viewer.md): The PDF Viewer component displays a PDF that's hosted on a web server by providing a URL to the source property.
- [Perspective - Progress](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-progress.md): The Progress bar visually indicates the progress of a task.
- [Perspective - Sparkline](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-sparkline.md): The Sparkline chart is a minimalistic chart component that displays a line-chart history for a single datapoint.
- [Displaying a Subview in a Table Row](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-table/displaying-a-subview-in-a-table-row.md): In a Perspective Table component, you have the option to enable subviews. When a subview is set up, you can click on the Expand icon and have anoth...
- [Perspective - Table Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-table/perspective-table-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [Table](perspective-table.md) component.
- [Perspective - Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-table.md): The Table component displays database data in tabular form.
- [Styling Rows Based on Values](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-table/styling-rows.md): This page includes examples detailing different ways to style rows based on values using Script Transforms. Each example accomplishes similiar resu...
- [Table Column Configurations](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-table/table-column-configurations.md): This page contains examples that involve making changes to a table component's columns property.
- [Perspective - Tag Browse Tree Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-tag-browse-tree/perspective-tag-browse-tree-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [Tag Browse Tree](perspective-tag-browse-tr...
- [Perspective - Tag Browse Tree](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-tag-browse-tree.md): The Tag Browse Tree component displays a tree hierarchy based on an array of objects.
- [Perspective - Thermometer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-thermometer.md): The Thermometer component displays a temperature value depicted as a level in a mercury thermometer.
- [Perspective - Tree Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-tree/perspective-tree-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [Tree](perspective-tree.md) component.
- [Perspective - Tree](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-tree.md): The Tree component displays a tree hierarchy based on an array of objects.
- [Perspective - Video Player](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-display-palette/perspective-video-player.md): The Video Player component enables you to embed video or a live feed in Perspective views.
- [Perspective - Accordion Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-accordion/perspective-accordion-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Accordion](perspective-accordion.md) compo...
- [Perspective - Accordion](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-accordion.md): The Accordion component allows the embedding of expandable/collapsible views.
- [Carousel Component Examples](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-carousel/carousel-component-examples.md): 
- [Perspective - Carousel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-carousel.md): The Carousel component allows you to display a selection of rotating views at a defined rate with a link to the view on a page in your project.
- [Perspective - Embedded View](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-embedded-view.md): The Embedded View component allows you to include an entire view inside another.
- [Perspective - Embedding Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette.md): The following components function a bit differently, but what they all have in common is that each component can be embedded in multiple views of a...
- [Perspective - Flex Repeater](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-flex-repeater.md): The Flex Repeater component lets you easily create multiple instances of views for display in another view.
- [Perspective - View Canvas Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-view-canvas/perspective-view-canvas-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's View Canvas](perspective-view-canvas.md) c...
- [Perspective - View Canvas](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-embedding-palette/perspective-view-canvas.md): The View Canvas component can display multiple Perspective views, each positioned on a coordinate based system.
- [Perspective - Barcode Scanner Input](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-barcode-scanner-input.md): The Barcode Scanner Input component awaits for input from a barcode scanner.
- [Perspective - Button](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-button.md): The Button component is used to initiate some sort of action in response to being pressed.
- [Perspective - Checkbox](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-checkbox.md): A Checkbox is a familiar component that represents a bit - it is either on (selected) or off (not selected).
- [Perspective - DateTime Input](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-datetime-input.md): A DateTime Input is an easy way to select a date from a popup calendar.
- [Perspective - DateTime Picker](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-datetime-picker.md): The DateTime Picker component uses the calendar to select the date and time.
- [Perspective - Dropdown](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-dropdown.md): The Dropdown component is a great way to display a list of choices in a limited amount of space.
- [Download and Upload Files](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-file-upload/download-and-upload-files.md): Downloading and uploading files from a Perspective session typically involves storing and retrieving files from a database. A table will store all ...
- [Perspective - File Upload Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-file-upload/perspective-file-upload-scripting.md): This page details the various scripting, component, and extension functions available for Perspective's [File Upload](appendix\components\perspecti...
- [Perspective - File Upload](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-file-upload.md): The File Upload component allows users to upload files to the Gateway or other locations from a Perspective session using a script action on the on...
- [Perspective - Form Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-form/perspective-form-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Form](perspective-form.md) component. Scri...
- [Perspective - Form](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-form.md): The Form component is used to create responsive and dynamic forms for user input and validation in Perspective.
- [Perspective - Input Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette.md):
- [Perspective - Multi-State Button](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-multistate-button.md): The Multi-State Button is really a series of two or more buttons, arranged in a column or row.
- [Perspective - Numeric Entry Field](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-numeric-entry-field.md): The Numeric Entry Field is similar to the standard Text Field, except that it is specialized for use with numbers.
- [Perspective - One-Shot Button](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-one-shot-button.md): The One-Shot Button is designed to send off a write request, and wait for a response, disabling the button until something resets the 'value' prope...
- [Perspective - Password Field](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-password-field.md): The Password Field component is similar to a Text Field component.
- [Perspective - Radio Group](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-radio-group.md): The Radio Group allows you to create multiple radio buttons in a single container.
- [Perspective - Signature Pad Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-signature-pad/perspective-signature-pad-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Signature Pad](perspective-signature-pad.m...
- [Perspective - Signature Pad](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-signature-pad.md): The Signature Pad component enables users to draw a signature and submit it.
- [Perspective - Slider](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-slider.md): The Slider component lets the user drag an indicator along a scale to choose a value in a range.
- [Perspective - Text Area](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-text-area.md): The Text Area component is suitable for multi-line text display and editing.
- [Perspective - Text Field](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-text-field.md): The Text Field component is used for input of any single-line text.
- [Perspective - Toggle Switch](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-input-palette/perspective-toggle-switch.md): The Toggle Switch represents a bit: on (selected) or off (not selected).
- [Navigating with the Horizontal Menu Component](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-navigation-palette/perspective-horizontal-menu/navigating-with-the-horizontal-menu-component.md): The Horizontal Menu component enables you to build a menu structure by setting up multiple links to different page URLs from the component. Our exa...
- [Perspective - Horizontal Menu Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-navigation-palette/perspective-horizontal-menu/perspective-horizontal-menu-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Horizontal Menu](../perspective-horizontal...
- [Perspective - Horizontal Menu](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-navigation-palette/perspective-horizontal-menu.md): The Horizontal Menu component enables you to build a menu structure by setting up multiple links to different page URLs from the component.
- [Perspective - Link](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-navigation-palette/perspective-link.md): The Link component allows users to create a hyperlink that points to a destination such as a page, view, resource, or mount path that they can quic...
- [Perspective - Menu Tree Scripting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-navigation-palette/perspective-menu-tree/perspective-menu-tree-scripting.md): This page details the various scripting, component, and extension functions available for [Perspective's Menu Tree](perspective-menu-tree.md) compo...
- [Perspective - Menu Tree](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-navigation-palette/perspective-menu-tree.md): The Menu Tree component can be configured to allow users to navigate pages in a Perspective Session.
- [Perspective - Navigation Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-navigation-palette.md): One of the most important aspects to consider when developing a Perspective application is a solid navigation design so the user knows where they a...
- [Perspective - Report Viewer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-report-viewer.md): The Report Viewer component allows embedding reports from the Reporting Module into a Perspective views.
- [Perspective - Motor](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-symbols-palette/perspective-motor.md): An animated component that looks like a motor.
- [Perspective - Pump](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-symbols-palette/perspective-pump.md): An animated component that looks like a pump.
- [Perspective - Sensor](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-symbols-palette/perspective-sensor.md): An animated component that looks like a sensor.
- [Perspective - Symbols Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-symbols-palette.md): The following symbol components provide you with design options for visualizing HMI. Click on the Symbol component name for a link pointing to a pa...
- [Perspective - Valve](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-symbols-palette/perspective-valve.md): A component that looks like a valve.
- [Perspective - Vessel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-symbols-palette/perspective-vessel.md): An animated component that looks like a tank or vessel. Options include displaying fill level, the stand, and the agitator.
- [Perspective - View Object](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/perspective-components/perspective-view-object.md): This is the view itself. A view has properties that control the view size, defines how tags are dropped into a view, and settings for loading clien...
- [Report Component - Bar Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-chart-palette/report-component-bar-chart.md): A Bar Chart is used to display data in a chart using bars.
- [Report Component - Pie Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-chart-palette/report-component-pie-chart.md): The Pie Chart takes a Data Source with two keys: a Label (typically a string) and a Value (typical a numerical value).
- [Report Component - Radar Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-chart-palette/report-component-radar-chart.md): A Radar Chart allows you to quickly see values in comparison to related items or groups.
- [Report Component - Timeseries Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-chart-palette/report-component-timeseries-chart.md): The Timeseries Chart, while similar to the XY Chart, uses a datetime value for the Domain Axis instead of a numerical value. This chart is ideal wh...
- [Report Component - XY Chart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-chart-palette/report-component-xy-chart.md): The XY Chart, while similar to the Timeseries Chart, uses a numerical value for the Domain Axis instead of a Datetime. The XY chart is ideal when t...
- [Report Design - Chart Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-chart-palette.md): The following components give you various chart types for displaying data in a report.
- [Report Design Components](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components.md): The Report module features many different report-specific components that are exclusively used inside the Report module.
- [Report - Barcode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-display-palette/report-component-barcode.md): The Barcode component allows reports to contain dynamically generated barcodes based on how you configure its properties.
- [Report - Images](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-display-palette/report-component-images.md): The Image component lets you embed images into reports.
- [Report - Labels](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-display-palette/report-component-labels.md): Labels can be used to print out a host of different types of labels depending on how you configure the Label properties.
- [Report Design - Display Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-display-palette.md): The following components provide various options for displaying values and data.
- [Report - Page Object](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-object-palette/report-component-page-object.md): Each report may consist of multiple pages. The Page component may be selected by clicking on a Page item in the Project Browser.
- [Report - Report Object](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-object-palette/report-component-report-object.md): The report itself. This component has properties that control the dimensions, margins, and more. These settings impact all pages in the report.
- [Report Design - Object Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-object-palette.md): The following are object components used solely by the Report Module.
- [Report - Ellipse Shape](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette/report-component-ellipse-shape.md): The Ellipse shape component creates circles and ellipses that can be used in a report.
- [Report - Line Shape](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette/report-component-line-shape.md): The Line shape component can be used to display a straight line any where in a report.
- [Report - Pencil Shape](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette/report-component-pencil-shape.md): The Pencil shape component lets you draw free-hand path segments that automatically smooth the curves.
- [Report - Polygon Shape](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette/report-component-polygon-shape.md): The Polygon shape component creates custom polygon shapes by drawing and connecting lines, and can be used anywhere on a report.
- [Report - Rectangle Shape](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette/report-component-rectangle-shape.md): The Rectangle shape component creates a square or rectangle and can be used anywhere on a report.
- [Report - Star Shape](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette/report-component-star-shape.md): The Star shape component creates a star and can be used anywhere on a report.
- [Report - Text Shape](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette/report-component-text-shape.md): The Text shape component creates a text area for static or data key bound content.
- [Report Design - Shape Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-shape-palette.md): The following components allow users to create shapes.
- [Report - Crosstab Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-table-palette/report-component-crosstab-table.md): CrossTab Tables are commonly used to summarize the relationship between two categories of data.
- [Report - Simple Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-table-palette/report-component-simple-table.md): The Simple Table is a grid-like table structure that dynamically creates new rows and columns for rows returned by the Data Keys on the component.
- [Report - Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-table-palette/report-component-table.md): The Report Table displays data in a structured, repetitious format which gives reporting users the ability to flexibly layout and organize tabular ...
- [Report Design - Table Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/report-design-components/report-design-table-palette.md): The following components offer various types of Tables for displaying values.
- [Vision - SFC Monitor](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin/SFC-monitor.md): A component to monitor SFC performance.
- [Vision - Admin Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin.md): The following components give you administrative access to various Gateway systems.
- [Vision - Roster Management Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin/roster-management/roster-management-scripting-functions.md): This page details the various component and extension functions available for Vision's Roster Management component.
- [Vision - Roster Management](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin/roster-management.md): The user management panel provides a built-in way to edit rosters from a client.
- [Vision - Schedule Management Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin/schedule-management/schedule-management-scripting-functions.md): This page details the various component and extension functions available for Vision's Schedule Management component.
- [Vision - Schedule Management](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin/schedule-management.md): This component allows for management of schedules.
- [Vision - User Management Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin/user-management/user-management-scripting-functions.md): This page details the various component and extension functions available for Vision's User Management component.
- [Vision - User Management](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/admin/user-management.md): The User Management panel provides a built-in way to edit users and roles from a client.
- [Vision Alarm Journal - Row Styles](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/alarming/alarm-journal-table/alarm-journal-row-styles.md):
- [Vision - Alarm Journal Table Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/alarming/alarm-journal-table/alarm-journal-table-scripting.md): This page details the various component and extension functions available for [Vision's Alarm Journal Table component](alarm-journal-table.md).
- [Vision - Alarm Journal Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/alarming/alarm-journal-table.md): The alarm journal table provides a built-in view to explore alarm history that has been stored in an alarm journal.
- [Vision - Alarm Row Style Customizer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/alarming/alarm-status-table/alarm-row-style-customizer.md): |Alarm Row Styles - Alarm Status Table | Alarm Row Styles - Alarm Journal Table|
- [Vision - Alarm Status Table Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/alarming/alarm-status-table/alarm-status-table-scripting.md): This page details the various component and extension functions available for [Vision's Alarm Status Table component](alarm-status-table.md).
- [Vision - Alarm Status Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/alarming/alarm-status-table.md): The alarm status table displays the current state of the alarm system. It can be configured to show active, unacknowledged, cleared, and acknowledg...
- [How to Filter by Associated Data on the Vision Alarm Status Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/alarming/alarm-status-table/how-to-filter-by-associated-data.md):
- [Vision - File Explorer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/file-explorer.md): The File Explorer component displays a filesystem tree to the user. It can be rooted at any folder, even network folders.
- [Vision - PDF Viewer Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/pdf-viewer/pdf-viewer-scripting.md): This page details the various component and extension functions available for Vision's PDF Viewer component.
- [Vision - PDF Viewer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/pdf-viewer.md): The PDF Viewer component displays a PDF that exists as a file in some accessible file system, or as a URL.
- [Using the PDF Viewer with the File Explorer Component](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/pdf-viewer/using-pdf-viewer-with-file-explorer.md):
- [Vision - Report Viewer Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/report-viewer/report-viewer-scripting.md): This page details the various component and extension functions available for Vision's [Report Viewer](report-viewer.md) component.
- [Vision - Report Viewer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/report-viewer.md): The Report Viewer component provides a way to run and view Reports in Vision windows.
- [Vision - Reporting Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components.md): The following components require the Report Module, and give you access to generated reports and various ways to filter and display data.
- [Vision - Row Selector](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/row-selector.md): The row selector is a component that acts like a visual filter for datasets.
- [Using the Row Selector](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/reporting-components/row-selector/using-the-row-selector.md):
- [Vision - Comments Panel Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/comments-panel/comments-panel-scripting-functions.md): This page details the various component and extension functions available for [Vision's Comments Panel component](comments-panel.md).
- [Vision - Comments Panel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/comments-panel.md): The comments panel is used to power a blog-style comments system within your project.
- [Vision - List Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/list/list-scripting-functions.md): This page details the various component and extension functions available for [Vision's List component](list.md).
- [Vision - List](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/list.md): The list component displays a list of options, allowing freeform selection of the items.
- [Vision - Power Table Customizer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/power-table/power-table-customizer.md): 
- [Vision - Power Table Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/power-table/power-table-scripting-functions.md): This page details the various component and extension functions available for [Vision's Power Table component](power-table.md).
- [Vision - Power Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/power-table.md): The power table is a more customizable version of the table component. The power table contains advanced features such as drag-and-drop rows, multi...
- [Working With Power Table Extension Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/power-table/working-with-power-table-extension-functions.md): The Power Table offers significantly more configuration options than the classic Table, including a number of extension functions, which allow furt...
- [Vision - Table Customizer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/table/table-customizer.md): 
- [Vision - Table Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/table/table-scripting-functions.md): This page details the various component and extension functions available for [Vision's Table component](table.md).
- [Vision - Table](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/table.md): The Table component is very powerful and easy to configure. It is very flexible, allowing you to easily display your tabular data in a variety of w...
- [Vision - Tables Palette](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables.md): The following components give you various types of tables for displaying values.
- [Vision - Tag Browse Tree Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/tag-browse-tree/tag-browse-tree-scripting-functions.md): This page details the various component and extension functions available for Vision's [Tag Browse Tree](tag-browse-tree.md) component.
- [Vision - Tag Browse Tree](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/tag-browse-tree.md): The Tag Browse Tree component is similar to the Tag Browser in the Designer, allowing tags to be browsed in both the Designer and the Client, and d...
- [Vision - Tree View Customizer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/tree-view/tree-view-customizer.md): 
- [Tree View Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/tree-view/tree-view-scripting-functions.md): This page details the various component and extension functions available for Vision's [Tree View](tree-view.md) component.
- [Vision - Tree View](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/tables/tree-view.md): The Tree View component can display any tree hierarchy. It is configured by filling in a dataset.
- [Vision Components](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components.md): This section covers all the built-in Vision components. While the component is selected, you can use the Property Editor panel to alter the compone...
- [Vision - The Window Object Scripting Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/vision-window-object/vision-window-object-scripting.md): This page details the various component and extension functions available for [Vision's Window Object components](vision-window-object.md).
- [Vision - The Window Object](https://www.docs.inductiveautomation.com/docs/8.3/appendix/components/vision-components/vision-window-object.md): Windows are the top-level unit of design for Vision projects.
- [JSON](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/JSON.md): The following functions allow you to manipulate JSON strings in expression bindings.
- [jsonFormat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/JSON/jsonFormat.md): Takes a string, and returns a prettyprints string
- [jsonGet](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/JSON/jsonGet.md): Takes a JSON friendly string and a path string, and returns the value of that path.
- [jsonSet](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/JSON/jsonSet.md): Takes a JSON friendly string, a path string, and value, and will return a new JSON friendly string with the provided path set to the provided value.
- [columnRearrange](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/columnRearrange.md): Returns a view of the given dataset with the given columns in the order specified.
- [columnRename](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/columnRename.md): Returns a view of the given dataset with the columns renamed.
- [forceQuality](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/forceQuality.md): Returns the given value, but overwrites the quality of that value.
- [Advanced](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced.md): The following functions allow you to interact with Ignition in more advanced ways through expression bindings.
- [property](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/property.md): Returns an object representing the value of the property at the path specified. It takes a single string as an argument and attempts to lookup the ...
- [qualifiedValue](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/qualifiedValue.md): Returns the given value, but overwrites the quality of that value.
- [qualityOf](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/qualityOf.md): Returns the QualityCode of a qualified value.
- [runScript](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/runScript.md): Runs a single line of Python code as an expression.
- [sortDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/sortDataset.md): Returns a new dataset based on the rows in the given dataset.
- [tag](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/tag.md): Returns an object representing the value of the Tag at the path specified.
- [timestampOf](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/timestampOf.md): Returns the timestamp of a qualified value.
- [typeOf](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/advanced/typeOf.md): Returns the simple name of the Java type.
- [groupConcat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/groupConcat.md): Concatenates all of the values in a specified column or collection into a string, with each value separated by the string separator.
- [Aggregates](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates.md): The following functions allow you to fetch aggregated values from datasets in expression bindings.
- [max](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/max.md): Finds and returns the maximum value in the given column of the given dataset, or the max value in a series of numbers specified as arguments.
- [maxDate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/maxDate.md): Finds and returns the maximum date in the given column of the given dataset, or the max value in a series of dates specified as arguments.
- [mean](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/mean.md): Calculates the mean (a.k.a average) for the numbers in the given column of the given dataset or the mean of a series of numbers specified as argume...
- [median](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/median.md): Calculates the median for the numbers in the given column of the given dataset or the median of a series of numbers specified as arguments.
- [min](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/min.md): Finds and returns the minimum value in the given column of the given dataset, or the min value in a series of numbers specified as arguments.
- [minDate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/minDate.md): Finds and returns the minimum date in the given column of the given dataset, or the min value in a series of dates specified as arguments.
- [stdDev](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/stdDev.md): Calculates the sample standard deviation of the values in the given column of the given dataset, or the standard deviation for a series of numbers ...
- [sum](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/aggregates/sum.md): Calculates the sum of the values in the given column of the given dataset, or the sum for a series of numbers specified as arguments.
- [Alarming](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/alarming.md): The following functions allow you to view alarm status in expression bindings.
- [isAlarmActive](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/alarming/isAlarmActive.md): Returns whether there are active alarms that match the provided criteria.
- [isAlarmActiveFiltered](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/alarming/isAlarmActiveFiltered.md): Returns whether there are active alarms that match the provided criteria.
- [brighter](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/colors/brighter.md): Returns a color that is one shade brighter than the color given as an argument.
- [color](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/colors/color.md): Creates a color using the given red, green, and blue amounts, which are integers between 0-255.
- [darker](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/colors/darker.md): Returns a color that is one shade darker than the color given as an argument.
- [gradient](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/colors/gradient.md): Calculates a percentage given the three numeric arguments number, low, and high.
- [Colors](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/colors.md): The following functions allow you to modify or set color values in expression bindings.
- [*Between](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/Between.md): Calculates the amount of time between two dates
- [add*](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/add.md): Add or subtract an amount to a given date and time
- [dateArithmetic](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateArithmetic.md): Adds or subtracts some amount of time from a date, returning the resulting date.
- [dateDiff](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateDiff.md): Calculates the difference between the two dates, returning the result as a floating point value in the units specified by field
- [dateExtract](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateExtract.md): Returns an integer value that is the value of the specified date field within the given date.
- [dateFormat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateFormat.md): Returns the given date as a string, formatted according to a pattern.
- [dateIsAfter](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateIsAfter.md): Compares two dates to see if date1 is after date2.
- [dateIsBefore](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateIsBefore.md): Compares two dates to see if date1 is before date2
- [dateIsBetween](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateIsBetween.md): Compares two dates to see if a target date is between two other dates.
- [dateIsDaylight](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/dateIsDaylight.md): Checks to see if the current timezone is using daylight savings time during the date specified.
- [fromMillis](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/fromMillis.md): Creates a date object given a millisecond value.
- [get*](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/get.md): Extracts a unit of time from a date
- [getDate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/getDate.md): Creates a new Date object given a year, month and a day.
- [getTimezone](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/getTimezone.md): Returns the ID of the current timezone depending on the scope in which it is called.
- [getTimezoneOffset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/getTimezoneOffset.md): Returns the current timezone's offset versus UTC for a given instant, taking Daylight Savings Time into account.
- [getTimezoneRawOffset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/getTimezoneRawOffset.md): Returns the current timezone offset versus UTC, not taking daylight savings into account.
- [Date and Time](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time.md): The following functions allow you to check or modify time values in expression bindings.
- [midnight](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/midnight.md): Returns a copy of a date with the hour, minute, second, and millisecond fields set to zero.
- [now](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/now.md): Returns the current time.
- [setTime](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/setTime.md): Takes in a date, and returns a copy of it with the time fields set as specified.
- [timeBetween](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/timeBetween.md): Checks to see if the given time is between the start and end times.
- [toMillis](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/date-and-time/toMillis.md): Converts a Date object to its millisecond value elapsed since January 1, 1970, 00:00:00 UTC (GMT)
- [containsAll](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/identity-provider/containsAll.md): This function checks to see if all of the listed elements are present in the collection object. The function requires at least two arguments, a col...
- [containsAny](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/identity-provider/containsAny.md): This function checks to see if any of the listed elements are present in the collection object. The function requires at least two arguments, a col...
- [Identity Provider](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/identity-provider.md): The following functions allow you to test whether specified elements are present in an IdP collection object. They can be used only in the Security...
- [Expression Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions.md): The expression language is used to define dynamic values for component properties and expression tags. Expressions often involve one or more other ...
- [binEnc](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/binEnc.md): Takes a list of booleans and treats them like the bits in a binary number.
- [binEnum](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/binEnum.md): Takes a list of booleans, and returns the index (starting at 1) of the first parameter that evaluates to true.
- [case](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/case.md): This function acts like the switch statement in C-like programming languages.
- [coalesce](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/coalesce.md): This function, which accepts any number of arguments, evaluates each in order, and returns the first non-null argument.
- [getBit](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/getBit.md): This function returns the bit value (an integer, 0 or 1) in the number at position position, according to its binary representation.
- [hasChanged](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/hasChanged.md): This function returns true if the given value has changed since the last time the Expression Item was run.
- [if](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/if.md): This function evaluates the expression condition, and returns the value of trueReturn or falseReturn depending on the boolean value of condition.
- [Logic](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic.md): The following functions allow you to perform logic and evaluate values in expression bindings.
- [indexOf](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/indexOf.md): Searches for the first occurrence of the substring inside of string. Returns the index of where substring was found, or -1 if it wasn't found.
- [isBad](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/isBad.md): Tests to see whether or not the given value's quality is bad.
- [isBadOrError](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/isBadOrError.md): Tests to see whether or not the given value's quality is either bad or error.
- [isError](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/isError.md): Tests to see whether or not the given value's quality is either error.
- [isGood](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/isGood.md): Tests to see whether or not the given value is good quality.
- [isNull](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/isNull.md): Tests to see whether or not the argument value is null
- [isUncertain](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/isUncertain.md): Tests to see whether or not the given value's quality is Uncertain.
- [lastIndexOf](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/lastIndexOf.md): Searches for the last occurrence of the substring inside of string.
- [len](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/len.md): Returns the length of the argument, which may be a string or a dataset.
- [lookup](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/lookup.md): This looks for lookupValue in the lookupColumn of dataset.
- [switch](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/switch.md): This function acts like the switch statement in C-like programming languages.
- [try](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/logic/try.md): This expression is used to swallow errors caused by other expressions.
- [abs](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/abs.md): Returns the absolute value of number.
- [acos](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/acos.md): Returns the arc cosine of number
- [asin](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/asin.md): Returns the arc sine of number
- [atan](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/atan.md): Returns the arc tangent of number
- [ceil](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/ceil.md): Returns the smallest floating point value that is greater than or equal to the argument and is equal to a mathematical integer.
- [cos](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/cos.md): Returns the trigonometric cosine of number
- [exp](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/exp.md): Returns Euler's number e raised to the power of the argument number, or enumber
- [floor](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/floor.md): Returns the largest floating point value that is less than or equal to the argument and is equal to a mathematical integer.
- [Math](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math.md): The following functions allow you to preform math functions on values in expression bindings.
- [log](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/log.md): Returns the natural logarithm (base e) of a number.
- [log10](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/log10.md): Returns the logarithm (base 10) of a number.
- [pow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/pow.md): Returns a number raised to a power.
- [round](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/round.md): Rounds a floating point number.
- [sin](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/sin.md): Returns the trigonometric sine of a number
- [sqrt](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/sqrt.md): Returns the square root of the argument number
- [tan](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/tan.md): Returns the trigonometric tangent of a number
- [todegrees](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/todegrees.md): Converts an angle measured in radians to an equivalent angle measured in degrees
- [toradians](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/math/toradians.md): Converts an angle measured in degrees to an equivalent angle measured in radians
- [MongoDB - Expression Binding](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/mongo-db.md): The following functions allow you to interact with MongoDB databases in expression bindings.
- [maxKey](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/mongo-db/maxKey.md): Returns org.bson.types.MaxKey, which is used in filters for the MongoDB Perspective binding expression.
- [minKey](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/mongo-db/minKey.md): Returns org.bson.types.MinKey, used in filters for the MongoDB Perspective binding expression.
- [toObjectId](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/mongo-db/toObjectId.md): Converts String to org.bson.types.ObjectId.
- [char](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/char.md): Takes a Unicode character code (as an integer), and returns the Unicode character as a string.
- [concat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/concat.md): Concatenates all of the strings passed in as arguments together.
- [escapeSQL](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/escapeSQL.md): Returns the given string with special SQL characters escaped.
- [escapeXML](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/escapeXML.md): Returns the given string after being escaped to be valid for inclusion in XML.
- [fromBinary](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/fromBinary.md): Returns an integer value of the binary formatted string argument.
- [fromHex](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/fromHex.md): Returns an integer value of the hex formatted string argument.
- [fromOctal](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/fromOctal.md): Returns an integer value of the octal formatted string argument.
- [String](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string.md): The following functions allow you to search or modify string values in expression bindings.
- [left](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/left.md): Returns count characters from the left side of string, where count and string are the arguments to the function.
- [lower](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/lower.md): Takes a string and returns a lower-case version of it.
- [numberFormat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/numberFormat.md): Returns a string version of the number argument, formatted as specified by the pattern string.
- [ordinal](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/ordinal.md): Takes a Unicode character (as a string), and returns the corresponding character code, as an integer.
- [repeat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/repeat.md): Repeats the given string some number of times.
- [replace](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/replace.md): Finds all occurrences of a substring inside of a source string, and replaces them with the replacement string.
- [right](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/right.md): Returns count number of characters starting from the right side of string, where count and string are the arguments to the function.
- [split](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/split.md): Takes the starting string and splits it into substrings
- [stringFormat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/stringFormat.md): This expression returns a formatted string using the specified format string and arguments. Mainly, this expression is used for building dynamic st...
- [substring](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/substring.md): Will return the portion of the string from the startIndex to the endIndex, or end of the string if endIndex is not specified
- [toBinary](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/toBinary.md): Returns a binary formatted string representing the unsigned integer argument.
- [toHex](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/toHex.md): Returns a hex formatted string representing the unsigned integer argument.
- [toOctal](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/toOctal.md): Returns an octal formatted string representing the unsigned integer argument.
- [trim](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/trim.md): Takes the argument string and trims of any leading and/or trailing whitespace
- [upper](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/upper.md): Takes a string and returns an uppercase version of it.
- [urlEncode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/string/urlEncode.md): Enables users to create an HTTP binding's URL on the fly.
- [Translation](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/translation.md): The following functions allow you to interact with the Translation system through expression bindings.
- [translate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/translation/translate.md): Returns a translated string, based on the current locale.
- [Type Casting](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting.md): The following functions allow you to change value types in expression bindings.
- [toBoolean](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toBoolean.md): Tries to convert value to a boolean
- [toBorder](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toBorder.md): This function is used specifically when binding a Border property on a component. Typically, this is used with a Container or Label component but c...
- [toColor](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toColor.md): This function tries to convert value to a color.
- [toDataSet](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toDataSet.md): Tries to coerce value into a dataset.
- [toDate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toDate.md): Tries to coerce value into a Date.
- [toDouble](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toDouble.md): Tries to coerce value into a double (64-bit floating point value).
- [toFloat](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toFloat.md): Tries to coerce value into a float (32-bit floating point vaule).
- [toFont](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toFont.md): Coerces a string into a font.
- [toInt](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toInt.md): Tries to coerce value into an integer (32-bit integer).
- [toInteger](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toInteger.md): Identical to the toInt expression function.
- [toLong](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toLong.md): Tries to coerce value into a long (64-bit integer).
- [toStr](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toStr.md): Identical to the toString expression function.
- [toString](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/type-casting/toString.md): Represents the value as a string. Will succeed for any type of value.
- [hasRole](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/users/hasRole.md): Returns true if the user has the given role. The username and usersource parameters are optional in the client scope, but required in the Gateway s...
- [Users](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/users.md): The following functions allow you to interact with the User/Role system through expression bindings.
- [isAuthorized](https://www.docs.inductiveautomation.com/docs/8.3/appendix/expression-functions/users/isAuthorized.md): Returns a qualified value with a boolean value which is true if the user in the current Session is authorized, false otherwise.
- [Charting - Right Click Menu](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/charting-right-click-menu.md): Learn more about the right-click menu on Vision's Easy Chart Component
- [Color Selector Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/color-selector-reference.md): Learn more about the color selection interface here
- [Crontab Formatting Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/crontab-formatting-reference.md): This page provides an overview on using crontab
- [Data Type Formatting Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/data-type-formatting-reference.md): This page formatting patterns for dates, numbers, and strings.
- [Gateway and Gateway Network Parameters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/gateway-configuration-file-reference/gateway-and-gateway-network-parameters.md): Gateway security headers system properties and default settings are listed below. These parameters impact Perspective sessions, as well as any page...
- [Gateway Configuration File Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/gateway-configuration-file-reference.md): This section details the various configuration changes that can be made to the Gateway's configuration file: `ignition.conf`. Before the Gateway st...
- [Perspective Parameters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/gateway-configuration-file-reference/perspective-parameters.md): Chrome and Safari handle browser cache differently than Edge and Firefox when it comes to hitting the ‘refresh’ or ‘reload’ button. Edge and Firefo...
- [Vision Client Parameters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/gateway-configuration-file-reference/vision-client-parameters.md): By default, error messages in the Designer and Client report a stack trace, which provides granular information about the source of the error. Howe...
- [Gateway Folder Structure Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/gateway-folder-structure.md): Learn more about the folder structure behind Ignition
- [Gateway Port Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/gateway-port-reference.md): The following table describes the default ports an Ignition server may use for communication.
- [Gateway XML File Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/gateway-xml-file-reference.md): This page describes the gateway.xml file located in the installation directory
- [Ignition Database Table Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/ignition-database-table-reference.md): Ignition has a lot of systems built-in that will query the database automatically without requiring you to build a query. These systems automatical...
- [Logback XML File Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/logback-xml-file-reference.md): This page describes the logback.xml file located in the installation directory
- [Perspective Event Types Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/perspective-event-types-reference.md): Learn more about events available under the Configure Events menu on Perspective components.
- [Platform Environment Variables](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/platform-environment-variables.md): The environment variables listed on this page are supported by the Ignition platform and work on a wide variety of operating systems including Dock...
- [Reference Pages](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages.md): This section is for various reference pages that may fall outside of a specific section in the User Manual.
- [resource.json File](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/resource-json-file.md): This page describes the contents on resource.json files
- [Scripting Object Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/scripting-object-reference.md): This page describes several common scripting objects
- [Style Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/style-reference.md): Learn more about the style user interface used in Perspective
- [Project Browser Symbol Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/symbol-reference/project-browser-symbol-reference.md): This page contains reference images for icons located in the Project Browser
- [Symbol Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/symbol-reference.md): The following reference pages provide tables showing the symbols and icons used in Ignition along with the symbol name and description.
- [Tag Browser Symbol Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/symbol-reference/tag-browser-symbol-reference.md): This page contains reference images for icons located in the Tag Browser
- [System Name Usage Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/system-name-usage-reference.md): Learn more about how the system name property on a gateway is referenced by other systems within Ignition
- [Web XML File Reference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/reference-pages/web-xml-file-reference.md): This page describes the web.xml file located in the installation directory
- [System Functions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions.md):
- [system.alarm.acknowledge](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-acknowledge.md): Acknowledges any number of alarms, specified by their event ids.
- [system.alarm.cancel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-cancel.md): Cancels any number of alarms, specified by their event ids.
- [system.alarm.createRoster](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-createRoster.md): This function creates a new roster. Users may be added to the roster through the Gateway or the Roster Management component
- [system.alarm.getRosters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-getRosters.md): This function returns a mapping of roster names to a list of usernames contained in the roster.
- [system.alarm.getShelvedPaths](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-getShelvedPaths.md): Returns a list of ShelvedPath objects, which each represent a shelved alarm.
- [system.alarm.listPipelines](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-listPipelines.md): Will return a list of the available Alarm Notification Pipelines in a project.
- [system.alarm.queryJournal](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-queryJournal.md): Queries the specified journal for historical alarm events.
- [system.alarm.queryStatus](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-queryStatus.md): Queries the current state of alarms. The result is a list of alarm events, which can be queried for individual properties.
- [system.alarm.shelve](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-shelve.md): This function shelves the specified alarms for the specified amount of time.
- [system.alarm.unshelve](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm/system-alarm-unshelve.md): Unshelves a list of alarms based on the source paths provided.
- [system.alarm](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-alarm.md): The following functions give you access to view and interact with the Alarm system in Ignition.
- [system.bacnet.readRaw](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet/system-bacnet-readRaw.md): Read from any BACnet object not explicitly supported by the BACnet driver.
- [system.bacnet.readRawMultiple](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet/system-bacnet-readRawMultiple.md): This function is the bulk version of system.bacnet.readRaw to allow multiple object/property combinations to be read simultaneously from a single r...
- [system.bacnet.synchronizeTime](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet/system-bacnet-synchronizeTime.md): Notifies the remote device of the correct current time, which is the system time (factoring in time zone and DST) of the server Ignition is running...
- [system.bacnet.synchronizeTimeUtc](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet/system-bacnet-synchronizeTimeUtc.md): Notifies the remote device of the correct current time in UTC.
- [system.bacnet.writeRaw](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet/system-bacnet-writeRaw.md): Write to any BACnet object not explicitly supported by the BACnet driver.
- [system.bacnet.writeRawMultiple](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet/system-bacnet-writeRawMultiple.md): This function is the bulk version of system.bacnet.writeRaw by writing properties to objects provided equal-length lists of object types, object in...
- [system.bacnet.writeWithPriority](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet/system-bacnet-writeWithPriority.md): Write to the Present_Value attribute of an object with a custom priority level.
- [system.bacnet](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-bacnet.md): The following functions are used with the [BACnet driver](ignition-modules\opc-ua\opc-ua-drivers\bacnet\bacnet.md) and a BACnet/IP device.
- [system.config.copy](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-copy.md): Copies a resource to a new name and/or collection. When using this function, either the newName or newCollection parameter must be defined.
- [system.config.create](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-create.md): Creates a new resource of the specified type.
- [system.config.delete](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-delete.md): Deletes a resource of the specified type.
- [system.config.getActiveMode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-getActiveMode.md): Returns the currently active resource collection mode, or None if no mode is explicitly active.
- [system.config.getModes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-getModes.md): Returns a list of all available resource collection modes.
- [system.config.getResource](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-getResource.md): Returns a single resource.
- [system.config.getResourceTypes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-getResourceTypes.md): Returns a list of all registered resource types.
- [system.config.getResources](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-getResources.md): Returns all resources of the specified type.
- [system.config.move](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-move.md): Moves a resource to a different collection.
- [system.config.rename](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-rename.md): Renames the specified resource.
- [system.config.replace](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config/system-config-replace.md): Replaces an existing resource completely with a new configuration.
- [system.config](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-config.md):
- [system.dataset.addColumn](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-addColumn.md): Takes a dataset and returns a new dataset with a new column added or inserted into it.
- [system.dataset.addRow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-addRow.md): Takes a dataset and returns a new dataset with a new row added or inserted into it.
- [system.dataset.addRows](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-addRows.md): Takes a dataset and returns a new dataset with new rows added or inserted into it.
- [system.dataset.appendDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-appendDataset.md): Takes two different datasets and returns a new dataset with the second dataset appended to the first.
- [system.dataset.clearDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-clearDataset.md): Takes a dataset and returns a new dataset with all of the same column names, but all of the rows deleted.
- [system.dataset.dataSetToHTML](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-dataSetToHTML.md): Formats the contents of a dataset as an HTML page, returning the results as a string.
- [system.dataset.deleteRow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-deleteRow.md): Takes a dataset and returns a new dataset with a row removed.
- [system.dataset.deleteRows](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-deleteRows.md): Takes a dataset and returns a new dataset with one or more rows removed.
- [system.dataset.filterColumns](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-filterColumns.md): Takes a dataset and returns a view of the dataset containing only the columns found within the given list of columns.
- [system.dataset.formatDates](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-formatDates.md): Returns a new dataset with Date columns as strings formatted according to the dateFormat specified.
- [system.dataset.fromCSV](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-fromCSV.md): Converts a dataset stored in a CSV formatted string to a dataset that can be immediately assignable to a dataset property in your project.
- [system.dataset.getColumnHeaders](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-getColumnHeaders.md): Takes in a dataset and returns the headers as a python list.
- [system.dataset.setValue](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-setValue.md): Takes a dataset and returns a new dataset with one value altered.
- [system.dataset.sort](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-sort.md): Sorts a dataset and returns the sorted dataset.
- [system.dataset.toCSV](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-toCSV.md): Formats the contents of a dataset as CSV (comma separated values), returning the resulting CSV as a string.
- [system.dataset.toDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-toDataset.md): This function is used to convert PyDatasets to datasets and create new datasets from raw Python lists. When creating a new dataset, headers should ...
- [system.dataset.toExcel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-toExcel.md): Formats the contents of one or more datasets as an Excel spreadsheet, returning the results as a byte array.
- [system.dataset.updateRow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset/system-dataset-updateRow.md): Takes a dataset and returns a new dataset with a one row altered.
- [system.dataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dataset.md): The following functions give you access to view and interact with datasets.
- [system.date.add*](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-add.md): Add or subtract an amount of time to a given date.
- [system.date.*Between](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-between.md): Calculates the amount of time between two dates.
- [system.date.format](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-format.md): Returns the given date as a string and formatted according to a pattern.
- [system.date.fromMillis](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-fromMillis.md): Creates a date object given a millisecond value
- [system.date.get*](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-get.md): Extracts a unit of time from a date.
- [system.date.getDate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-getDate.md): Creates a new Date object given a year, month and a day.
- [system.date.getTimezone](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-getTimezone.md): Returns the ID of the current timezone.
- [system.date.getTimezoneRawOffset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-getTimezoneRawOffset.md): Returns the current timezone offset versus UTC, not taking daylight savings into account.
- [system.date.getTimezoneOffset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-getTmezoneOffset.md): Returns the current timezone's offset versus UTC for a given instant, taking Daylight Savings Time into account.
- [system.date.isAfter](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-isAfter.md): Compares two dates to see if date_1 is after date_2.
- [system.date.isBefore](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-isBefore.md): Compares two dates to see if date_1 is before date_2.
- [system.date.isBetween](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-isBetween.md): Compares two dates to see if a target date is between two other dates.
- [system.date.isDaylightTime](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-isDaylightTime.md): Checks to see if the current timezone is using daylight savings time during the date specified.
- [system.date.midnight](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-midnight.md): Returns a copy of a date with the hour, minute, second, and millisecond fields set to zero.
- [system.date.now](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-now.md): Returns a java.util.Date object that represents the current time according to the local system clock.
- [system.date.parse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-parse.md): Attempts to parse a string and create a Date.
- [system.date.setTime](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-setTime.md): Takes in a date, and returns a copy of it with the time fields set as specified.
- [system.date.toMillis](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date/system-date-toMillis.md): Converts a Date object to its millisecond value elapsed since January 1, 1970, 00:00:00 UTC (GMT)
- [system.date](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-date.md): The following functions give you access to test and modify dates.
- [system.db.addDatasource](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-addDatasource.md): Adds a new database connection in Ignition.
- [system.db.beginNamedQueryTransaction](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-beginNamedQueryTransaction.md): Begins a new database named query transaction.
- [system.db.beginTransaction](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-beginTransaction.md): Begins a new database transaction.
- [system.db.clearQueryCache](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-clearQueryCache.md): Clears the cache for a Named Query in a project.
- [system.db.closeTransaction](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-closeTransaction.md): Closes the transaction with the given ID.
- [system.db.commitTransaction](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-commitTransaction.md): Performs a commit for the given transaction.
- [system.db.createSProcCall](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-createSProcCall.md): Creates an SProcCall object, which is a stored procedure call context.
- [system.db.execQuery](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-execQuery.md): Executes a select query from a Named Query resource.
- [system.db.execSProcCall](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-execSProcCall.md): Executes a stored procedure call.
- [system.db.execScalar](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-execScalar.md): Executes a scalar query from a Named Query resource.
- [system.db.execUpdate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-execUpdate.md): Executes an update query from a Named Query resource.
- [system.db.execUpdateAsync](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-execUpdateAsync.md): Executes an update query through the Store and Forward system.
- [system.db.getConnectionInfo](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-getConnectionInfo.md): Returns a dataset of information about a single database connection, as specified by the name argument.
- [system.db.getConnections](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-getConnections.md): Returns a dataset of information about each configured database connection. Each row represents a single connection.
- [system.db.removeDatasource](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-removeDatasource.md): Removes a database connection from Ignition.
- [system.db.rollbackTransaction](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-rollbackTransaction.md): Performs a rollback on the given connection.
- [system.db.runPrepQuery](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-runPrepQuery.md): Runs a prepared statement against the database, returning the results in a PyDataSet.
- [system.db.runPrepUpdate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-runPrepUpdate.md): Runs a prepared statement against the database, returning the number of rows that were affected.
- [system.db.runSFPrepUpdate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-runSFPrepUpdate.md): Runs a prepared statement query through the store and forward system and to multiple data sources at the same time.
- [system.db.runScalarPrepQuery](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-runScalarPrepQuery.md): Runs a prepared statement against a database connection just like the runPrepQuery function, but only returns the value from the first row and column.
- [system.db.setDatasourceConnectURL](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-setDatasourceConnectURL.md): Changes the connect URL for a given database connection.
- [system.db.setDatasourceEnabled](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-setDatasourceEnabled.md): Enables/disables a given database connection.
- [system.db.setDatasourceMaxConnections](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db/system-db-setDatasourceMaxConnections.md): Sets the Max Active and Max Idle parameters of a given database connection.
- [system.db](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-db.md): The following functions give you access to view and modify data in the database.
- [system.device.addDevice - deviceProps Listing](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-addDevice/system-device-addDevice-deviceProps-Listing.md): Below is a table of properties callable by system.device.addDevice.
- [system.device.addDevice](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-addDevice.md): This function is used in **Python Scripting**.
- [system.device.getDeviceHostname](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-getDeviceHostname.md): Returns the hostname of the device.
- [system.device.listDevices](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-listDevices.md): Returns a dataset of information about each configured device.
- [system.device.refreshBrowse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-refreshBrowse.md): Forces Ignition to browse the controller.
- [system.device.removeDevice](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-removeDevice.md): Removes a given device from Ignition.
- [system.device.restart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-restart.md): Restarts the named device connection.
- [system.device.setDeviceEnabled](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-setDeviceEnabled.md): Enables/disables a device in Ignition.
- [system.device.setDeviceHostname](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device/system-device-setDeviceHostname.md): Changes the hostname of a device. Used for all ethernet based drivers.
- [system.device](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-device.md): The following functions give you access to view and edit device connections in the Gateway.
- [system.dnp.demandPoll](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-demandPoll.md): Issues a poll request for one or more classes.
- [system.dnp.directOperateAnalog](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-directOperateAnalog.md): Performs a Direct Operate command on an analog point.
- [system.dnp.directOperateBinary](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-directOperateBinary.md): Performs a Direct Operate command on a binary point.
- [system.dnp.freezeAnalogs](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-freezeAnalogs.md): Issues an Immediate Freeze command targeting one or more analog points.
- [system.dnp.freezeAtTimeAnalogs](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-freezeAtTimeAnalogs.md): Issues a Freeze at Time command targeting one or more analog points.
- [system.dnp.freezeAtTimeCounters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-freezeAtTimeCounters.md): Issues a Freeze at Time command targeting one or more counters.
- [system.dnp.freezeClearAnalogs](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-freezeClearAnalogs.md): Issues a Freeze and Clear command targeting one or more analog points.
- [system.dnp.freezeClearCounters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-freezeClearCounters.md): Issues a Freeze and Clear command targeting one or more counters.
- [system.dnp.freezeCounters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-freezeCounters.md): Issues an Immediate Freeze command targeting one or more counters.
- [system.dnp.selectOperateAnalog](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-selectOperateAnalog.md): Performs a Select then Operate command on an analog point.
- [system.dnp.selectOperateBinary](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-selectOperateBinary.md): Performs a Select then Operate command on a binary point.
- [system.dnp.synchronizeTime](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp/system-dnp-synchronizeTime.md): Issues a Synchronize Time command using the current Ignition Gateway time.
- [system.dnp](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp.md): :::note
- [system.dnp3.directOperateAnalog](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-directOperateAnalog.md): Issues a Select-And-Operate command to set an analog value in an analog output point.
- [system.dnp3.directOperateBinary](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-directOperateBinary.md): Issues a Direct-Operate command for digital control operations at binary output points (CROB).
- [system.dnp3.freezeAnalogs](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-freezeAnalogs.md): Issues a freeze command on the given analog outputs.
- [system.dnp3.freezeAnalogsAtTime](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-freezeAnalogsAtTime.md): Issues a freeze command on the given analog outputs at the given time for the specified duration.
- [system.dnp3.freezeCounters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-freezeCounters.md): Issues a freeze command on the given counters.
- [system.dnp3.freezeCountersAtTime](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-freezeCountersAtTime.md): Issues a freeze command on the given counters at the given time for the specified duration.
- [system.dnp3.selectOperateAnalog](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-selectOperateAnalog.md): Issues a Select-And-Operate command to set an analog value in an analog output point.
- [system.dnp3.selectOperateBinary](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3/system-dnp3-selectOperateBinary.md): Issues a Select-And-Operate command for digital control operations at binary output points (CROB).
- [system.dnp3](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-dnp3.md): :::note
- [system.eam.getGroups](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eam/system-eam-getGroups.md): Returns the names of the defined agent organizational groups in the Gateway.
- [system.eam.queryAgentHistory](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eam/system-eam-queryAgentHistory.md): Returns a list of the most recent agent events.
- [system.eam.queryAgentStatus](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eam/system-eam-queryAgentStatus.md): Returns the current state of the matching agents.
- [system.eam.runTask](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eam/system-eam-runTask.md): Takes the name of a task as an argument as a string (must be configured on the Controller before hand), attempts to execute the task.
- [system.eam](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eam.md): The following functions give you access to view EAM information from the Gateway.
- [system.eventstream.getDiagnostics](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eventstream/system-eventstream-getDiagnostics.md): Retrieves diagnostics for an event stream.
- [system.eventstream.listEventStreams](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eventstream/system-eventstream-listEventStreams.md): Lists event stream resource paths that are part of the specified project.
- [system.eventstream.publishEvent](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eventstream/system-eventstream-publishEvent.md): Publishes a message to a Gateway Event Source.
- [system.eventstream](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-eventstream.md): The following functions allow you to get and run event stream information.
- [system.file.fileExists](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-file/system-file-fileExists.md): Checks to see if a file or folder at a given path exists.
- [system.file.getTempFile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-file/system-file-getTempFile.md): Creates a new temp file on the host machine with a certain extension, returning the path to the file.
- [system.file.readFileAsBytes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-file/system-file-readFileAsBytes.md): Opens the file found at path filename, and reads the entire file.
- [system.file.readFileAsString](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-file/system-file-readFileAsString.md): Opens the file found at path filename, and reads the entire file. Returns the file as a string.
- [system.file.writeFile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-file/system-file-writeFile.md): Writes the given data to the file at file path filename.
- [system.file](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-file.md): The following functions give you access to read and write to files.
- [system.groups.loadFromFile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-groups/system-groups-loadFromFile.md): Loads a transaction group configuration from an xml export, into the specified project (creating the project if necessary).
- [system.groups.removeGroups](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-groups/system-groups-removeGroups.md): Removes the specified groups from the project.
- [system.groups](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-groups.md): The following functions give you access to import and remove Transaction Groups.
- [system.historian.browse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-browse.md): Returns a list of browse results for the specified historian.
- [system.historian.deleteAnnotations](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-deleteAnnotations.md): Deletes desired annotations from the specified historian.
- [system.historian.queryAggregatedPoints](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-queryAggregatedPoints.md): Queries aggregated data points for the specified historian.
- [system.historian.queryAnnotations](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-queryAnnotations.md): Queries annotations for the specified historian.
- [system.historian.queryMetadata](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-queryMetadata.md): Queries metadata for the specified historian.
- [system.historian.queryRawPoints](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-queryRawPoints.md): Queries raw data points for the specified historian.
- [system.historian.storeAnnotations](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-storeAnnotations.md): Store a list of annotations to the specified historian.
- [system.historian.storeDataPoints](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-storeDataPoints.md): Store a list of data points to the specified historian.
- [system.historian.storeMetadata](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-storeMetadata.md): Store a list of metadata to the specified historian.
- [system.historian.updateRegisteredNodePath](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/system-historian-updateRegisteredNodePath.md): Updates the existing historical path for a stored historian node to the newly specific path.
- [system.historian](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian.md): The following functions give you access to interact with the Historian system.
- [system.historian.types.annotationPoint](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/types/system-historian-types-annotationPoint.md): Creates an annotation point that can be stored to a historian.
- [system.historian.types.dataPoint](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/types/system-historian-types-dataPoint.md): Creates a data point that can be stored to a historian.
- [system.historian.types.metadataPoint](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/types/system-historian-types-metadataPoint.md): Creates a metadata point that can be stored to a historian.
- [Types](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-historian/types.md): The following types are used to construct historian objects for scripting workflows, such as storing annotations, data points, and metadata.
- [system.iec61850.cancel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850/system-iec61850-cancel.md): Cancels the selection of an SBO type control on a configured IEC 61850 device to prevent the operate command from performing.
- [system.iec61850.getControlParams](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850/system-iec61850-getControlParams.md): This function returns a list of report control names and their attributes contained in the configured IEC 61850 device.
- [system.iec61850.listFiles](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850/system-iec61850-listFiles.md): This function returns a list of filenames from a remote path for the configured IEC 61850 device.
- [system.iec61850.operate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850/system-iec61850-operate.md): This function operates on the IEC 61850 device control immediately, such as to change the position of a switch.
- [system.iec61850.readFile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850/system-iec61850-readFile.md): This function downloads remote files from the configured IEC 61850 device to an identified local path.
- [system.iec61850.select](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850/system-iec61850-select.md): Select an SBO type control to prepare it for a subsequent operate command for a configured IEC 61850 device.
- [system.iec61850.writeFile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850/system-iec61850-writeFile.md): This function uploads a file from a local path to the configured IEC 61850 device remote path.
- [system.iec61850](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-iec61850.md): The following functions give you access to interact with IEC 61850 devices.
- [system.kafka.listConnectorInfo](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-listConnectorInfo.md): Returns descriptions of all Kafka connectors in PyDictionary format.
- [system.kafka.listTopicPartitions](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-listTopicPartitions.md): Returns a list of records that match the filter.
- [system.kafka.listTopics](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-listTopics.md): Returns a list of topics for the provided connector.
- [system.kafka.pollPartition](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-pollPartition.md): Returns a list of records polled from a specified partition.
- [system.kafka.pollTopic](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-pollTopic.md): Returns a list of records from the specified topic.
- [system.kafka.seekLatest](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-seekLatest.md): Retrieves the last N number of records from a specified topic.
- [system.kafka.sendRecord](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-sendRecord.md): Sends a record to a specified topic.
- [system.kafka.sendRecordAsync](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka/system-kafka-sendRecordAsync.md): Sends a record to a specified topic asynchronously.
- [system.kafka](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-kafka.md): The following functions allow you to poll and distribute data with a Kafka system.
- [system.math.geometricMean](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-geometricMean.md): Calculates the geometric mean.
- [system.math.kurtosis](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-kurtosis.md): Calculates the kurtosis of a sequence of values.
- [system.math.max](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-max.md): Given a sequence of values, returns the greatest value in the sequence, also known as the "max" value.
- [system.math.mean](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-mean.md): Given a sequence of values, calculates the arithmetic mean (average).
- [system.math.meanDifference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-meanDifference.md): Given two sequences of values, calculates the mean of the signed difference between both sequences.
- [system.math.median](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-median.md): Takes a sequence of values, and returns the median.
- [system.math.min](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-min.md): Given a sequence of numerical values, returns the minimum value, also known as the "min" value.
- [system.math.mode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-mode.md): Given a sequence of values, returns the 'mode', or most frequent values.
- [system.math.normalize](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-normalize.md): Given a sequence of values, normalizes the values.
- [system.math.percentile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-percentile.md): Given a sequence of numerical values, estimates the percentile of input.
- [system.math.populationVariance](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-populationVariance.md): Given a sequence of values, returns the population variance.
- [system.math.product](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-product.md): Given a sequence of values, calculates the product of the sequence.
- [system.math.skewness](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-skewness.md): Given a sequence of values, calculates the skewness (third central moment).
- [system.math.standardDeviation](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-standardDeviation.md): Given a sequence of numerical values, calculates the simple standard deviation.
- [system.math.sum](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-sum.md): Given a sequence of values, calculates the sum of all values.
- [system.math.sumDifference](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-sumDifference.md): Given two sequences of values, calculates the sum of the signed difference between both sequences.
- [system.math.sumLog](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-sumLog.md): Given a sequence of values, calculates the sum of the natural logs.
- [system.math.sumSquares](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-sumSquares.md): Given a sequence of values, calculates the sum of the squares of all values.
- [system.math.variance](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math/system-math-variance.md): Given a sequence of values, calculates the variance of all values.
- [system.math](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-math.md): The following functions assist with running statistical analysis.
- [system.mongodb.aggregate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-aggregate.md): Returns a list of aggregate results.
- [system.mongodb.deleteMany](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-deleteMany.md): Removes documents from the collection that match the filter.
- [system.mongodb.deleteOne](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-deleteOne.md): Removes a document from the collection that matches the filter.
- [system.mongodb.find](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-find.md): Returns a list of PyDictionaries that matches the criteria specified on the filter parameter.
- [system.mongodb.findOne](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-findOne.md): Returns a single PyDictionary that matches the criteria specified on the filter parameter.
- [system.mongodb.insertMany](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-insertMany.md): Inserts a list of PyDictionaries into a specified collection.
- [system.mongodb.insertOne](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-insertOne.md): Inserts a single PyDictionary into a specified collection.
- [system.mongodb.listCollectionNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-listCollectionNames.md): Returns a list of all collection names.
- [system.mongodb.listConnectorInfo](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-listConnectorInfo.md): Returns a list of PyDictionary descriptors of all MongoDB Connectors.
- [system.mongodb.replaceOne](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-replaceOne.md): Replaces a document in the collection that matches the filter.
- [system.mongodb.updateMany](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-updateMany.md): Updates all documents in the collection that match the filter.
- [system.mongodb.updateOne](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb/system-mongodb-updateOne.md): Updates a document in the collection that matches the filter.
- [system.mongodb](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-mongodb.md): The following functions allow users to interact with a MongoDB instance. These functions require the MongoDB connector.
- [system.net.getHostName](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-net/system-net-getHostName.md): Returns the host name of the computer that the client is currently running on
- [system.net.getIpAddress](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-net/system-net-getIpAddress.md): Returns the IP address of the computer the client is running on, as it appears to the client.
- [system.net.getRemoteServers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-net/system-net-getRemoteServers.md): This function returns a List of Gateway Network servers that are visible from the local Gateway.
- [system.net.httpClient](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-net/system-net-httpClient.md): Provides a general use object that can be used to send and receive HTTP requests.
- [system.net.sendEmail](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-net/system-net-sendEmail.md): Sends an email through the given SMTP server.
- [system.net](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-net.md): The following functions give you access to interact with http services.
- [system.opc.browse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-browse.md): Allows browsing of the OPC servers in the runtime, returning a list of tags.
- [system.opc.browseServer](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-browseServer.md): When called from a Vision Client, Perspective Session, or the Designer, returns a list of OPCBrowseElement objects for the given server. Otherwise,...
- [system.opc.browseSimple](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-browseSimple.md): Allows browsing of OPC servers in the runtime returning a list of tags.
- [system.opc.getServerState](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-getServerState.md): Retrieves the current state of the given OPC server connection.
- [system.opc.getServers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-getServers.md): Returns a list of server names.
- [system.opc.isServerEnabled](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-isServerEnabled.md): Checks if an OPC server connection is enabled or disabled.
- [system.opc.readValue](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-readValue.md): Reads a single value directly from an OPC server connection.
- [system.opc.readValues](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-readValues.md): This function is equivalent to the system.opc.readValue function, except that it can operate in bulk.
- [system.opc.setServerEnabled](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-setServerEnabled.md): Enables or disables an OPC server connection.
- [system.opc.writeValue](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-writeValue.md): Writes a value directly through an OPC server connection synchronously.
- [system.opc.writeValues](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc/system-opc-writeValues.md): This function is a bulk version of system.opc.writeValue.
- [system.opc](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opc.md): The following functions allow you to read, write, and browse OPC servers.
- [system.opchda.browse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-browse.md): Performs a browse at the given root.
- [system.opchda.getAggregates](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-getAggregates.md): Will query the server for aggregates that it supports.
- [system.opchda.getAttributes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-getAttributes.md): Queries the given server for the item attributes that are available with system.opchda.readAttributes.
- [system.opchda.getServers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-getServers.md): Returns a list of the OPC-HDA servers configured on the system.
- [system.opchda.insert](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-insert.md): Insert values on the OPC-HDA server.
- [system.opchda.insertReplace](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-insertReplace.md): Will insert values on the OPC-HDA server, or replace them if they already exist.
- [system.opchda.isServerAvailable](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-isServerAvailable.md): Checks to see if the specified OPC-HDA server is defined, enabled, and connected.
- [system.opchda.readAttributes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-readAttributes.md): Reads the specified attributes for the given item over a time range.
- [system.opchda.readProcessed](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-readProcessed.md): Reads processed values from the OPC-HDA server.
- [system.opchda.readRaw](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-readRaw.md): Reads raw values from the OPC-HDA server.
- [system.opchda.replace](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda/system-opchda-replace.md): Replaces values on the OPC-HDA server if the given item ID exists.
- [system.opchda](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opchda.md): The following functions give you access to interact with the HDA types of OPC servers.
- [system.opcua.addConnection](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opcua/system-opcua-addConnection.md): Adds a new OPC UA connection.
- [system.opcua.callMethod](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opcua/system-opcua-callMethod.md): Calls a method in an OPC UA server.
- [system.opcua.removeConnection](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opcua/system-opcua-removeConnection.md): Removes an OPC UA Connection.
- [system.opcua](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-opcua.md): The following functions allow you to interact directly with an OPC UA server.
- [system.perspective.alterDock](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-alterDock.md): Changes configuration of a specified dock on a Perspective page.
- [system.perspective.alterLogging](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-alterLogging.md): Changes Perspective Session logging attributes and levels.
- [system.perspective.authenticationChallenge](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-authenticationChallenge.md): Triggers an authentication challenge action.
- [system.perspective.closeDock](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-closeDock.md): Closes a docked view.
- [system.perspective.closePage](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-closePage.md): Closes the page with the given page id or the current page if no page id is provided.
- [system.perspective.closePopup](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-closePopup.md): Closes a popup view.
- [system.perspective.closeSession](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-closeSession.md): Closes the Perspective Session with the given sessionID or the current Session if no ID is provided.
- [system.perspective.download](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-download.md): Downloads data from the Gateway to a device running a Session.
- [system.perspective.getProjectInfo](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-getProjectInfo.md): Returns a dictionary of meta data from a Perspective Project.
- [system.perspective.getSessionInfo](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-getSessionInfo.md): Returns information about one or more Perspective Sessions.
- [system.perspective.isAuthorized](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-isAuthorized.md): Checks if the user in the current Session is authorized against a target collection of security levels.
- [system.perspective.login](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-login.md): Triggers a login event that will allow the user to log in with the project's configured Identity Provider (IdP).
- [system.perspective.logout](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-logout.md): Triggers a logout event, which will log the user out.
- [system.perspective.navigate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-navigate.md): Navigate a Session to a specified view or mounted page.
- [system.perspective.navigateBack](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-navigateBack.md): Navigate the session to a specified view or mounted page.
- [system.perspective.navigateForward](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-navigateForward.md): Navigate the session to a specified view or mounted page. This is similar to a browser's "forward" function.
- [system.perspective.openDock](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-openDock.md): Opens a docked View. Requires the preconfigured dock ID for the view.
- [system.perspective.openPopup](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-openPopup.md): Open a popup view over the given page.
- [system.perspective.print](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-print.md): Prints the supplied message to the local console or the gateway logs, as appropriate.
- [system.perspective.refresh](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-refresh.md): Triggers a refresh of the page.
- [system.perspective.sendMessage](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-sendMessage.md): Send a message to a message handler within the same session.
- [system.perspective.setTheme](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-setTheme.md): Changes the theme in a page to the specified theme.
- [system.perspective.toggleDock](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-toggleDock.md): Toggles a docked view.
- [system.perspective.togglePopup](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-togglePopup.md): Opens or closes a popup view.
- [system.perspective.vibrateDevice](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-vibrateDevice.md): Cause a device running the Perspective Mobile App to vibrate.
- [system.perspective.workstation.exit](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-workstation/system-perspective-workstation-exit.md): When called from a session running in Workstation, this function will close Workstation.
- [system.perspective.workstation.toKiosk](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-workstation/system-perspective-workstation-toKiosk.md): Attempts to put Workstation into Kiosk mode.
- [system.perspective.workstation.toWindowed](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-workstation/system-perspective-workstation-toWindowed.md): Attempts to put Workstation into Windowed mode.
- [system.perspective.workstation](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective/system-perspective-workstation.md): The following functions offer various ways to interact with Perspective Workstation from a Python script. Note that the functions here only work wh...
- [system.perspective](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-perspective.md): The following functions offer various ways to interact with a Perspective session from a Python script.
- [system.print.getDefaultPrinterName](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-print/system-print-getDefaultPrinterName.md): Obtains the local default printer.
- [system.print.getPrinterNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-print/system-print-getPrinterNames.md): Lists the available local printers.
- [system.print](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-print.md): The following functions allow you to send to a printer.
- [system.project.getProjectName](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-project/system-project-getProjectName.md): Returns the name of the project where the function was called from.
- [system.project.getProjectNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-project/system-project-getProjectNames.md): Returns an unsorted collection of strings, where each string represents the name of a project on the Gateway.
- [system.project.requestScan](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-project/system-project-requestScan.md): Requests a manual scan of the projects directory in order to refresh projects and their resources.
- [system.project](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-project.md): The following functions allow you to list projects on the Gateway through scripting.
- [system.report.executeAndDistribute](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-report/system-report-executeAndDistribute.md): Executes and distributes a report.
- [system.report.executeReport](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-report/system-report-executeReport.md): Immediately executes an existing report and returns a List[Byte] of the output.
- [system.report.getReportNamesAsDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-report/system-report-getReportNamesAsDataset.md): Gets a data of all reports for a project.
- [system.report.getReportNamesAsList](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-report/system-report-getReportNamesAsList.md): Gets a list of all reports for a project.
- [system.report](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-report.md): The following functions give you access to report details and the ability to run reports.
- [system.roster.addUsers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-addUsers.md): Adds a list of users to an existing roster. Users are always appended to the end of the roster.
- [system.roster.createRoster](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-createRoster.md): Creates a roster with the given name and description, if it does not already exist.
- [system.roster.deleteRoster](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-deleteRoster.md): Deletes a roster with the given name.
- [system.roster.getRoster](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-getRoster.md): Returns the roster corresponding to the given name.
- [system.roster.getRosterNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-getRosterNames.md): Returns a list of roster names.
- [system.roster.getRosters](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-getRosters.md): Returns a dictionary of rosters, where the key is the name of the roster, and the value is an array list of string user names.
- [system.roster.getUsers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-getUsers.md): Returns the list of users corresponding to the given rosterName.
- [system.roster.removeUsers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster/system-roster-removeUsers.md): Removes one or more users from an existing roster.
- [system.roster](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-roster.md): Functions that provide roster manipulation, including adding and remove users from a roster.
- [system.secrets.createEmbeddedSecretConfig](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-createEmbeddedSecretConfig.md): Creates a new Embedded SecretConfig instance.
- [system.secrets.createReferencedSecretConfig](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-createReferencedSecretConfig.md): Creates a new Referenced SecretConfig instance.
- [system.secrets.decrypt](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-decrypt.md): Decrypts the given JSON object containing an encrypted secret.
- [system.secrets.encrypt](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-encrypt.md): Encrypts data using the Secrets Management system encryption service.
- [system.secrets.getProviders](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-getProviders.md): Browses a list of Secret Providers configured on the Gateway.
- [system.secrets.getSecrets](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-getSecrets.md): Returns a list of all secrets for a named Secret Provider.
- [system.secrets.readConfiguredSecretValue](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-readConfiguredSecretValue.md): Reads the value of a secret.
- [system.secrets.readSecretValue](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets/system-secrets-readSecretValue.md): Reads the plaintext value of a secret.
- [system.secrets](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secrets.md):
- [system.secsgem.deleteToolProgram](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secgem-deleteToolProgram.md): Deletes a process program from the Gateway.
- [system.secsgem.copyEquipment](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-copyEquipment.md): Creates a copy of an equipment connection.
- [system.secsgem.enableDisableEquipment](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-enableDisableEquipment.md): Enables or disables a Tuple of equipment connections from a script.
- [system.secsgem.getResponse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-getResponse.md): Attempts to retrieve a response message from the Gateway.
- [system.secsgem.getToolProgram](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-getToolProgram.md): Returns a process program from the Gateway that was previously sent by a a tool in an S7F3 message.
- [system.secsgem.getToolProgramDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-getToolProgramDataset.md): Returns a Dataset containing information about all stored process programs.
- [system.secsgem.sendRequest](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-sendRequest.md): Sends a JSON-formatted SECS message to a tool.
- [system.secsgem.sendResponse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-sendResponse.md): Sends a JSON-formatted SECS response message to a message sent by a tool.
- [system.secsgem.startSimEventRun](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-startSimEventRun.md): Starts a configured simulator event run in the Gateway.
- [system.secsgem.toDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-toDataset.md): Converts a SECS message data structure, as returned by the system.secsgem.getResponse function, into a dataset and returns it.
- [system.secsgem.toTreeDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem/system-secsgem-toTreeDataset.md): Changes an existing dataset, as returned by the system.secsgem.toDataSet function, to make it usable for the Tree View component.
- [system.secsgem](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-secsgem.md): The following functions allow you to interact with equipment defined by the SECS/GEM module. Note that the [SECS/GEM](ignition-modules/secs-gem/sec...
- [system.security.getUserRoles](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-security/system-security-getUserRoles.md): Fetches the roles for a user from the Gateway.
- [system.security.validateUser](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-security/system-security-validateUser.md): Tests credentials (username and password) against an authentication profile.
- [system.security](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-security.md): The following functions give you access to interact with the users and roles in the Gateway. These functions require the Vision module, as these fu...
- [system.serial.closeSerialPort](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-closeSerialPort.md): Closes a previously opened serial port.
- [system.serial.configureSerialPort](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-configureSerialPort.md): Configure a serial port for use in a later call.
- [system.serial.openSerialPort](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-openSerialPort.md): Opens a previously configured serial port for use.
- [system.serial.port](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-port.md): Returns a context manager wrapping a serial port, allowing the rest of the system to interact with that port.
- [system.serial.readBytes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-readBytes.md): Read numberOfBytes bytes from a serial port.
- [system.serial.readBytesAsString](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-readBytesAsString.md): Read numberOfBytes bytes from a serial port and convert them to a String.
- [system.serial.readLine](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-readLine.md): Attempts to read a line from a serial port.
- [system.serial.readUntil](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-readUntil.md): Reads a byte at a time from a serial port until a delimiter character is encountered.
- [system.serial.sendBreak](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-sendBreak.md): Sends a break signal for approximately millis milliseconds.
- [system.serial.write](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-write.md): Write a String to a serial port using the platforms default character encoding.
- [system.serial.writeBytes](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial/system-serial-writeBytes.md): Write a List[Byte] to a serial port.
- [system.serial](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-serial.md): The following functions give you access to read and write through serial ports.
- [system.sfc.cancelChart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-cancelChart.md): Cancels the execution of a running chart instance.
- [system.sfc.getRunningCharts](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-getRunningCharts.md): Retrieves information about running charts.
- [system.sfc.getVariables](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-getVariables.md): Get the variables in a chart instance's scope.
- [system.sfc.pauseChart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-pauseChart.md): Pauses a running chart instance.
- [system.sfc.redundantCheckpoint](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-redundantCheckpoint.md): Synchronizes chart and step variables of the specified chart instance across a redundant cluster.
- [system.sfc.resumeChart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-resumeChart.md): Resumes a chart that was paused.
- [system.sfc.setVariable](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-setVariable.md): Sets a variable inside a currently running chart.
- [system.sfc.setVariables](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-setVariables.md): Sets any number of variables inside a currently running chart.
- [system.sfc.startChart](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc/system-sfc-startChart.md): Starts a new instance of a chart.
- [system.sfc](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-sfc.md): The following functions give you access to interact with the SFCs in the Gateway.
- [system.tag.browse](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-browse.md): Returns a list of nodes found at the specified path.
- [system.tag.configure](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-configure.md): Creates tags from a given list of Python dictionaries or from a JSON source string.
- [system.tag.copy](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-copy.md): Copies Tags from one folder to another.
- [system.tag.deleteTags](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-deleteTags.md): Deletes multiple tags or tag folders.
- [system.tag.exists](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-exists.md): Checks whether or not a tag with a given path exists.
- [system.tag.exportTags](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-exportTags.md): Exports tags to a file on a local file system.
- [system.tag.getConfiguration](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-getConfiguration.md): Retrieves tags from the Gateway as Python dictionaries.
- [system.tag.importTags](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-importTags.md): Imports a JSON tag file at the provided path.
- [system.tag.move](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-move.md): Moves tags or folders to a new destination.
- [system.tag.query](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-query.md): Queries a Tag Provider to produce a list of tags that meet the specified criteria.
- [system.tag.readAsync](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-readAsync.md): Asynchronously reads the value of the tags at the given paths.
- [system.tag.readBlocking](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-readBlocking.md): Reads the value of the tags at the given paths.
- [system.tag.rename](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-rename.md): Renames a single tag or folder.
- [system.tag.requestGroupExecution](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-requestGroupExecution.md): Sends a request to the specified tag group to execute now.
- [system.tag.writeAsync](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-writeAsync.md): Asynchronously writes values to tags at specified paths.
- [system.tag.writeBlocking](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag/system-tag-writeBlocking.md): Writes values to tags at the given paths.
- [system.tag](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-tag.md): The following functions give you access to interact with Ignition Tags.
- [system.twilio.getAccounts](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-getAccounts.md): Returns a list of Twilio account names that have been configured in the Gateway.
- [system.twilio.getAccountsDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-getAccountsDataset.md): Returns a list of Twilio account names that have been configured in the Gateway as a single-column Dataset.
- [system.twilio.getActiveCall](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-getActiveCalls.md): Returns a list of configurations for currently active Twilio voice calls.
- [system.twilio.getPhoneNumbers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-getPhoneNumbers.md): Returns a list of outgoing phone numbers for a Twilio account.
- [system.twilio.getPhoneNumbersDataset](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-getPhoneNumbersDataset.md): Returns a list of outgoing phone numbers for a Twilio account as a single-column Dataset.
- [system.twilio.sendFreeformWhatsApp](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-sendFreeformWhatsApp.md): Sends a free-form WhatsApp message.
- [system.twilio.sendPhoneCall](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-sendPhoneCall.md): Sends a phone call to a specific phone number.
- [system.twilio.sendSms](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-sendSms.md): Sends an SMS message.
- [system.twilio.sendWhatsAppTemplate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio/system-twilio-sendWhatsAppTemplate.md): Sends a WhatsApp template message.
- [system.twilio](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-twilio.md): The following functions give you access to read info and send SMS through Twilio. This requires the [Twilio Module](ignition-modules\alarm-notifica...
- [system.user.addCompositeSchedule](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-addCompositeSchedule.md): Allows two schedules to be combined into a composite schedule.
- [system.user.addHoliday](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-addHoliday.md): Allows a holiday to be added.
- [system.user.addRole](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-addRole.md): Adds a role to the specified user source.
- [system.user.addSchedule](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-addSchedule.md): Adds a schedule.
- [system.user.addUser](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-addUser.md): Adds a new user to a user source.
- [system.user.createScheduleAdjustment](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-createScheduleAdjustment.md): Creates a schedule adjustment.
- [system.user.editHoliday](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-editHoliday.md): Allows a holiday to be edited.
- [system.user.editRole](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-editRole.md): Renames a role in the specified user source.
- [system.user.editSchedule](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-editSchedule.md): Allows a schedule to be edited.
- [system.user.editUser](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-editUser.md): Alters a specific user in a user source, replacing the previous data with the new data passed in.
- [system.user.getHoliday](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getHoliday.md): Returns a specific holiday.
- [system.user.getHolidayNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getHolidayNames.md): Returns a collection of Strings of all holiday names.
- [system.user.getHolidays](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getHolidays.md): Returns a sequence of all of the holidays available.
- [system.user.getNewUser](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getNewUser.md): Creates a new user object.
- [system.user.getRoles](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getRoles.md): Returns a sequence of strings representing all of the roles configured in a specific user source.
- [system.user.getSchedule](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getSchedule.md): Returns a specific schedule.
- [system.user.getScheduleNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getScheduleNames.md): Returns a sequence of strings representing the names of all of the schedules available.
- [system.user.getScheduledUsers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getScheduledUsers.md): Returns a list of users that are scheduled.
- [system.user.getSchedules](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getSchedules.md): Returns a sequence of all available schedule models, which can be used to return configuration information on the schedule, such as time for each d...
- [system.user.getUser](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getUser.md): Looks up a specific user in a user source, by username.
- [system.user.getUserSources](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getUserSources.md): Returns a sequence of objects representing all of the user source profiles configured in the Gateway.
- [system.user.getUsers](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-getUsers.md): Retrieves the list of users in a specific user source.
- [system.user.isUserScheduled](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-isUserScheduled.md): Will check if a specified User is scheduled currently or on a specified date/time.
- [system.user.removeHoliday](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-removeHoliday.md): Allows a holiday to be deleted.
- [system.user.removeRole](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-removeRole.md): Removes a role from the specified user source.
- [system.user.removeSchedule](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-removeSchedule.md): Allows a schedule to be deleted.
- [system.user.removeUser](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user/system-user-removeUser.md): Removes a specific user from the a user source based on username.
- [system.user](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-user.md): The following functions give you access to view and edit users.
- [system.util.audit](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-audit.md): Inserts a record into an audit profile.
- [system.util.execute](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-execute.md): Executes the given commands via the operating system, in a separate process.
- [system.util.getGatewayStatus](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getGatewayStatus.md): Returns a string that indicates the status of the Gateway.
- [system.util.getGlobals](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getGlobals.md): This method returns a dictionary that provides access to the legacy global namespace.
- [system.util.getLogger](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getLogger.md): Returns a Logger object that can be used to log messages to the console.
- [system.util.getModules](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getModules.md): Returns a dataset of information about each installed module.
- [system.util.getProjectName](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getProjectName.md): Returns the name of the project that is currently being run.
- [system.util.getProperty](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getProperty.md): Retrieves the value of a named system property.
- [system.util.getSessionInfo](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getSessionInfo.md): Returns a PyDataSet holding information about all of the open Designer sessions and Vision Clients.
- [system.util.getVersion](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-getVersion.md): Returns the Ignition version number that is currently being run.
- [system.util.invokeAsynchronous](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-invokeAsynchronous.md): Invokes (calls) the given Python function on a different thread.
- [system.util.jsonDecode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-jsonDecode.md): Takes a JSON string and converts it into a Python object such as a list or a dictionary.
- [system.util.jsonEncode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-jsonEncode.md): Takes a Python object such as a list or dictionary and converts into a JSON string.
- [system.util.modifyTranslation](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-modifyTranslation.md): This function allows you to add or modify a global translation.
- [system.util.queryAuditLog](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-queryAuditLog.md): Queries an audit profile for audit history.
- [system.util.sendMessage](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-sendMessage.md): This function sends a message to clients running under the Gateway, or to a project within the Gateway itself.
- [system.util.sendRequest](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-sendRequest.md): This function sends a message to the Gateway, working in a similar manner to the sendMessage function, except sendRequest expects a response to the...
- [system.util.sendRequestAsync](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-sendRequestAsync.md): This function sends a message to the Gateway and expects a response.
- [system.util.setLoggingLevel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-setLoggingLevel.md): Sets the logging level on the given logger.
- [system.util.threadDump](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-threadDump.md): Creates a thread dump of the current running JVM.
- [system.util.translate](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util/system-util-translate.md): This function allows you to retrieve the global translation of a term from the translation database using the current locale.
- [system.util](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-util.md): The following functions give you access to view various Gateway and Client data, as well as interact with other various systems.
- [system.vision.beep](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-beep.md): Tells the computer where the script is running to make a "beep" sound.
- [system.vision.centerWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-centerWindow.md): Given a window path, or a reference to a window itself, it will center the window.
- [system.vision.closeDesktop](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-closeDesktop.md): Allows you to close any of the open desktops associated with the current client.
- [system.vision.closeParentWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-closeParentWindow.md): Closes the parent window given a component event object.
- [system.vision.closeWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-closeWindow.md): Given a window path, or a reference to a window itself, it will close the window.
- [system.vision.color](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-color.md): Creates a new color object, either by parsing a string or by having the RGB[A] channels specified explicitly.
- [system.vision.createImage](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-createImage.md): Takes a snapshot of a component and creates a Java BufferedImage out of it.
- [system.vision.createPopupMenu](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-createPopupMenu.md): Creates a new popup menu, which can then be shown over a component on a mouse event.
- [system.vision.createPrintJob](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-createPrintJob.md): Provides a general printing facility for printing the contents of a window or component to a printer.
- [system.vision.desktop](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-desktop.md): Allows for invoking system.vision functions on a specific desktop.
- [system.vision.exit](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-exit.md): Exits the running Client, as long as the shutdown intercept script doesn't cancel the shutdown event.
- [system.vision.exportCSV](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-exportCSV.md): Exports the contents of a dataset as a CSV file, prompting the user to save the file to disk.
- [system.vision.exportExcel](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-exportExcel.md): Exports the contents of a dataset as an Excel spreadsheet, prompting the user to save the file to disk.
- [system.vision.exportHTML](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-exportHTML.md): Exports the contents of a dataset to an HTML page. Prompts the user to save the file to disk.
- [system.vision.findWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-findWindow.md): Finds and returns a list of windows with the given path.
- [system.vision.getAvailableLocales](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getAvailableLocales.md): Returns a collection of the locales defined on the system, as strings.
- [system.vision.getAvailableTerms](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getAvailableTerms.md): Returns a collection of available terms defined in the translation system.
- [system.vision.getClientId](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getClientId.md): Returns a hex-string that represents a number unique to the running Client's session.
- [system.vision.getConnectTimeout](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getConnectTimeout.md): Returns the connect timeout in milliseconds for all Client-to-Gateway communication.
- [system.vision.getConnectionMode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getConnectionMode.md): Retrieves this Client session's current connection mode.
- [system.vision.getCurrentDesktop](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getCurrentDesktop.md): Returns the handle of the desktop this function was called from.
- [system.vision.getCurrentWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getCurrentWindow.md): Returns the path of the current "main screen" window, which is defined as the maximized window.
- [system.vision.getDesktopHandles](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getDesktopHandles.md): Gets a list of all secondary handles of the open desktops associated with the current client.
- [system.vision.getEdition](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getEdition.md): Returns the edition of the Vision Client.
- [system.vision.getExternalIpAddress](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getExternalIpAddress.md): Returns the Client's IP address, as it is detected by the Gateway.
- [system.vision.getGatewayAddress](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getGatewayAddress.md): Returns the address of the Gateway that the Client is currently communicating with.
- [system.vision.getInactivitySeconds](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getInactivitySeconds.md): Returns the number of seconds since any keyboard or mouse activity.
- [system.vision.getKeyboardLayouts](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getKeyboardLayouts.md): Returns a list of keyboard layouts available on this system.
- [system.vision.getLocale](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getLocale.md): Returns the current string representing the user's Locale, such as 'en' for English.
- [system.vision.getOpenedWindowNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getOpenedWindowNames.md): Finds all of the currently open windows and returns a tuple of their paths.
- [system.vision.getOpenedWindows](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getOpenedWindows.md): Finds all of the currently open windows and returns a tuple of references to them.
- [system.vision.getParentWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getParentWindow.md): Finds the parent (enclosing) window for the component that fired an event and returns a reference to it.
- [system.vision.getReadTimeout](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getReadTimeout.md): Returns the read timeout in milliseconds for all client-to-gateway communication.
- [system.vision.getRoles](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getRoles.md): Finds the roles that the currently logged in user has, returns them as a Python tuple of strings.
- [system.vision.getScreenIndex](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getScreenIndex.md): Returns an integer value representing the current screen index based on the screen from which this function was called.
- [system.vision.getScreens](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getScreens.md): Get a list of all the monitors on the computer this client is open on.
- [system.vision.getSibling](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getSibling.md): Given a component event object, looks up a sibling component.
- [system.vision.getSystemFlags](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getSystemFlags.md): Returns an integer that represents a bit field containing information about the currently running system.
- [system.vision.getUsername](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getUsername.md): Returns the currently logged-in username.
- [system.vision.getWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getWindow.md): Finds a reference to an open window with the given name.
- [system.vision.getWindowNames](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-getWindowNames.md): Returns a list of the paths of all windows in the current project, sorted alphabetically.
- [system.vision.goBack](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-goBack.md): When using the Typical Navigation Strategy, this function will navigate back to the previous main screen window.
- [system.vision.goForward](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-goForward.md): Navigates "forward" to the last main-screen window the user was on when they executed a system.vision.goBack().
- [system.vision.goHome](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-goHome.md): When using the Typical Navigation Strategy, this function will navigate to the "home" window.
- [system.vision.invokeLater](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-invokeLater.md): Invokes (calls) the given Python function object after all of the currently processing and pending events are done being processed, or after a spec...
- [system.vision.isOverlaysEnabled](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-isOverlaysEnabled.md): Returns whether or not the current client's quality overlay system is currently enabled.
- [system.vision.isScreenLocked](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-isScreenLocked.md): Returns whether or not the screen is currently locked.
- [system.vision.isTouchscreenMode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-isTouchscreenMode.md): Checks whether or not the running Client's Touch Screen mode is currently enabled.
- [system.vision.lockScreen](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-lockScreen.md): Used to put a running client in lock-screen mode.
- [system.vision.logout](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-logout.md): Logs out of the client for the current user and brings the client to the login screen.
- [system.vision.openDesktop](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-openDesktop.md): Creates an additional Desktop in a new frame.
- [system.vision.openFile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-openFile.md): Shows an Open File dialog box, prompting the user to choose a file to open.
- [system.vision.openFiles](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-openFiles.md): Shows an Open File dialog box, prompting the user to choose a file or files to open.
- [system.vision.openURL](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-openURL.md): Opens the given URL or URI scheme outside of the currently running Client in whatever application the host operating system deems appropriate.
- [system.vision.openWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-openWindow.md): Opens the window with the given path.
- [system.vision.openWindowInstance](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-openWindowInstance.md): Operates exactly like system.vision.openWindow, except that if the named window is already open, then an additional instance of the window will be ...
- [system.vision.playSoundClip](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-playSoundClip.md): Plays a sound clip from a wav file to the system's default audio device.
- [system.vision.printToImage](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-printToImage.md): This function prints the given component (such as a graph, container, entire window, etc) to an image file, and saves the file where ever the opera...
- [system.vision.refreshBinding](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-refresh.md): This function will programmatically cause a SQL Query or DB Browse property binding to execute immediately.
- [system.vision.retarget](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-retarget.md): This function allows you to programmatically 'retarget' a Vision Client to a different project and/or different Gateway.
- [system.vision.saveFile](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-saveFile.md): Prompts the user to save a new file named filename.
- [system.vision.setConnectTimeout](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-setConnectTimeout.md): Sets the connect timeout for Client-to-Gateway communication.
- [system.vision.setConnectionMode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-setConnectionMode.md): Sets the connection mode for the Client session.
- [system.vision.setLocale](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-setLocale.md): Sets the user's current Locale.
- [system.vision.setOverlaysEnabled](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-setOverlaysEnabled.md): Enables or disables the component quality overlay system.
- [system.vision.setReadTimeout](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-setReadTimeout.md): Sets the read timeout for Client-to-Gateway communication.
- [system.vision.setScreenIndex](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-setScreenIndex.md): Moves an open client to a specific monitor.
- [system.vision.setTouchscreenMode](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-setTouchscreenMode.md): Alters a running Client's Touch Screen mode on the fly.
- [system.vision.showColorInput](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showColorInput.md): Prompts the user to pick a color using the default color-chooser dialog box.
- [system.vision.showConfirm](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showConfirm.md): Displays a confirmation dialog box to the user with Yes and No options, and a custom message.
- [system.vision.showDiagnostics](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showDiagnostics.md): Opens the client runtime diagnostics window, which provides information regarding performance, logging, active threads, connection status, and the ...
- [system.vision.showError](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showError.md): Displays an error-style message box to the user.
- [system.vision.showInput](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showInput.md): Opens up a popup input dialog box.
- [system.vision.showMessage](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showMessage.md): Displays an informational-style message popup box to the user.
- [system.vision.showNumericKeypad](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showNumericKeypad.md): Displays a modal on-screen numeric keypad, allowing for arbitrary numeric entry using the mouse, or a finger on a touchscreen monitor.
- [system.vision.showPasswordInput](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showPasswordInput.md): Pops up a special input box that uses a password field, so the text isn't echoed back in clear-text to the user.
- [system.vision.showTouchscreenKeyboard](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showTouchscreenKeyboard.md): Displays a modal on-screen keyboard, allowing for arbitrary text entry using the mouse, or a finger on a touchscreen monitor.
- [system.vision.showWarning](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-showWarning.md): Displays a message to the user in a warning style popup dialog.
- [system.vision.swapTo](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-swapTo.md): Performs a window swap from the current main screen window to the window specified.
- [system.vision.swapWindow](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-swapWindow.md): Performs a window swap.
- [system.vision.switchUser](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-switchUser.md): Attempts to switch the current user on the fly.
- [system.vision.transform](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-transform.md): Sets a component's position and size at runtime.
- [system.vision.unlockScreen](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-unlockScreen.md): Unlocks the client, if it is currently in lock-screen mode.
- [system.vision.updateProject](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision/system-vision-updateProject.md): Updates the Vision Client project with saved changes.
- [system.vision](https://www.docs.inductiveautomation.com/docs/8.3/appendix/scripting-functions/system-vision.md): The following functions will allow you to update your Vision Client project using scripting, control windows, and create popup interfaces.
- [Resource Guides](https://www.docs.inductiveautomation.com/docs/8.3/tutorials.md):
- [Version and Source Control Guide](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/version-control-guide.md): Learn more about best practices for setting up version control in Ignition.
- [Best Practices for Using Git in a Team Environment](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/version-control-guide/best-practices-for-team-environments.md): The following is aimed to outline best practices for using Git effectively in a team environment.
- [Ignition 8 Deployment Best Practices](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/ignition-8-deployment-best-practices.md): Learn more about best practices for setting up development and testing workflows
- [Ignition Historian Guide](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/ignition-historian-guide.md): Ignition’s data historian functionality is a robust set of features that are built into Ignition modules, providing data acquisition, storage, retr...
- [Ignition Simulations and Games](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/ignition-simulations-and-games.md): Learning activities that simulate Ignition projects and Choose-Your-Own-Adventure games that put your knowledge to work.
- [Accessing Projects Remotely](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/accessing-projects-remotely.md): This page provides an overview of different methods to access your Ignition Vision and Perspective projects from a remote location. Once created, P...
- [Development Server Best Practices](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/development-server-best-practices.md): General recommendations for setting up your own development server
- [Mapping a Network Drive](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/mapping-a-network-drive.md): Learn how to make a network drive available to Ignition
- [Migrating Servers](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/migrating-servers.md): This page outlines the steps to migrate an Ignition Gateway from one server to another. A common use case for this would be if you are upgrading s...
- [Optimize Gateway Network Performance](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/optimize-gateway-network-performance.md): Tips on how to better optimize your Gateway Network
- [Recommended Anti-Virus and Endpoint Security Settings with Ignition](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/recommended-anti-virus-and-enpoint-security-settings.md): A list of common anti-virus software exclusions to allow full Ignition functionality.
- [Scale-Out Architecture Guide](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/scale-out-architecture-guide.md): A guide demonstrating how to migrate to a scale-out architecture
- [Secure Disposal Guide](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/secure-disposal-guide.md): Learn how to securely remove Ignition from a server
- [Tag History vs. Transaction Groups](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/tag-history-vs-transaction-groups.md): In this article, you will be informed on different manufacturing process types and which of Ignition’s data logging solutions are known to work best.
- [Tutorials and Helpful Tricks](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks.md): This section includes helpful information and guides for doing specific tasks within Ignition.
- [Working with Long File Paths](https://www.docs.inductiveautomation.com/docs/8.3/tutorials/tutorials-and-helpful-tricks/working-with-long-paths.md): [Ignition's data folder structure](appendix/reference-pages/gateway-folder-structure/gateway-folder-structure.md) can lead to long file paths that ...