Vision - Line
Component Palette Icon:
Description​
The line component displays a straight line. It can run north-south, east-west, or diagonally. You can add arrows to either side. The line can be dashed using any pattern you want. You can even draw the line like a sinusoidal wave.
Reporting Line Component
If you are looking for the Line component used in Reporting, refer to Report - Line Shape.
Properties​
| Name | Description | Property Type | Scripting | Category | 
|---|---|---|---|---|
| Color | Set the color of the line. Can be chosen from color wheel, chosen from color palette, or entered as RGB or HSL value. See Color Selector. | Color | .foreground | Appearance | 
| Cursor | The mouse cursor to use when hovering over this component. Options are: Default, Crosshair, Text, Wait, Hand, Move, SW Resize, or SE Resize. | int | .cursorCode | Common | 
| Dash Pattern | Enter a string of comma-delimited numbers which indicate the stroke pattern for a dashed line. For instance, "3,5" means three pixels on, five pixels off. | String | .strokePattern | Appearance | 
| Left Arrow | Draw an arrow head on the left/top of the line? | boolean | .leftArrow | Appearance | 
| Left Arrow Size | The size of the left arrow, if present. | int | .leftArrowSize | Appearance | 
| Line Mode | The line mode determines where in the rectangle the line is drawn. | int | .lineMode | Appearance | 
| Line Style | The line style determines how the shape of the line looks. Options are: Plane, Dashed, Sinusoidal, Sinusoidal-Dashed, Loop, and Loop-Dashed. | int | .lineStyle | Appearance | 
| Line Width | Set the width of the line in pixels. | int | .lineWidth | Appearance | 
| Mouseover Text | The text that is displayed in the tooltip which pops up on mouseover of this component. | String | .toolTipText | Common | 
| Name | The name of this component. | String | .name | Common | 
| Quality | The data quality code for any Tag bindings on this component. | QualityCode | .quality | Data | 
| Right Arrow | Draw an arrow head on the right/bottom of the line? | boolean | .rightArrow | Appearance | 
| Right Arrow Size | The size of the right arrow, if present. | int | .rightArrowSize | Appearance | 
| Sine Height | Sets the amplitude of the sine wave to be drawn. | int | .sineHeight | Appearance | 
| Sine Length | Sets the wavelength of the sine wave to be drawn. | int | .sineLength | Appearance | 
| Styles | Contains the component's styles. | Dataset | .styles | Appearance | 
| Visible | If disabled, the component will be hidden. | boolean | .visible | Common | 
Scripting​
Component Functions​
This component does not have component functions associated with it.
Extension Functions​
This component does not have extension functions associated with it.
Event Handlers​
Event handlers allow you to run a script based off specific triggers. See the full list of available event handlers on the Component Events page
Customizers​
Examples​
Line with Sinusoidal Pattern​
| Property | Setting | 
|---|---|
| Color | 0,0,255 | 
| Line Style | Sinusoidal | 
Line with Arrow Endpoints​
| Property | Setting | 
|---|---|
| Color | 217,0,0 | 
| Line Style | Plain | 
| Left Arrow | True | 
| Left Arrow Size | 25 | 
| Line Width | 4 | 
| Right Arrow | True | 
| Right Arrow Size | 25 |