--- title: "system.mongodb.deleteOne" description: "Removes a document from the collection that matches the filter." --- # system.mongodb.deleteOne > Removes a document from the collection that matches the filter. This function is used in **Python Scripting**. :::note Project Library scripts will not provide hints for MongoDB system functions unless the Script Hint Scope is set to **Gateway**. See the [Scripting in Ignition](platform\scripting\scripting-in-ignition\scripting-in-ignition.md#system-functions-hints-and-autocomplete) page for more details on scripting hints. ::: ## Description ## Client Permission Restrictions This scripting function has no [Client Permission](../../../ignition-modules/vision/vision-project-properties/vision-project-properties.md#vision-permissions-properties) restrictions. ## Syntax `system.mongodb.deleteOne(connector, collection, filter, [options])` ### Parameters Type | Parameter | Description ------- | ------- | ------ String| `connector` | The name of connector (case-insensitive). String| `collection` | The name of collection (case-sensitive). PyDictionary| `filter` | A PyDictionary for specifying matching key value pair criteria when querying a collection. PyDictionary| `options` | A PyDictionary for including additional delete configurations. [optional] ### Returns **PyDictionary** `result` - Result of delete action formatted as a PyDictionary with keys ‘acknowledged’ and ‘deleteCount’. ### Scope Gateway, Perspective Session ## Code Examples ```python title="Example #1" # Import required BSON types. from system.mongodb.types import ObjectId # Specify unique field values to locate specific document. Here we are specifying the known _id of the document. filter = {"_id": ObjectId("63fe3941519feb58abb3cda1")} # Apply parameters for function call. print system.mongodb.deleteOne("MongoDB", "customers", filter) ```