--- title: "Project Browser Symbol Reference" description: "This page contains reference images for icons located in the Project Browser" --- # Project Browser Symbol Reference > This page contains reference images for icons located in the Project Browser This reference section provides tables showing the symbols used in Project Browser along with the symbol name and description. ## Project Browser Icons ### Miscellaneous |Symbol|Name|Description| |:---:|:---|:---| |![](Alarming.png)|Alarming|Workspace for [Alarm Notification Pipelines](ignition-modules\alarm-notification\alarm-notification.md). Appears under the Global resources. The same icon is displayed next to the name of each pipeline.| |![](Sequential%20Function%20Charts.png)|Sequential Function Charts|Workspace for [Sequential Function Charts](ignition-modules\sequential-function-charts\sequential-function-charts.md) (SFC). Same icon is displayed next to the name of each SFC.| |![](Properties.png)|Properties|Opens the [Project Properties Editor](platform\projects\projects.md) dialog box.| ### ![](Scripts.png) Scripting |Symbol|Name|Description| |:---:|:---|:---| |![](Script%20Library.png)|Project Library|Workspace for the Project Library.| |![](Script.png)|Script|Icon for an individual script. Appears next to the name of the script.| |![](image2018-11-19_16-34-10.png)|Gateway Events|Scripts for events that execute on the Gateway.| ### ![](Perspective.png) Perspective Additional symbols (Badge icons) can show up to the right of these items. See the [Perspective Designer Interface](ignition-modules\perspective\perspective-designer-interface.md) page for an explanation. |Symbol|Name|Description| |:---:|:---|:---| |![](Client%20Event%20Scripts.png)|[Perspective Session Events](ignition-modules\perspective\scripting-in-perspective\perspective-session-events-scripts.md)|Scripts for events that occur during a Perspective Session.| |![](Folder.png)|[Styles](ignition-modules\perspective\styles\styles.md)|Styles folder within Perspective.| |![](Folder.png)|Views|Views folder within Perspective.| |![](Perspective-view.png)|View|Icon for an individual View. Appears next to the name of the View.| |![](Perspective-edit.png)|Edit View|Edits a View within Perspective.| ### ![](Transaction%20Groups.png) Transaction Groups |Symbol|Name|Description| |:---:|:---|:---| |![](2018-11-20_11-57-10.png)|Standard Group|Icon for a block Standard Group.| |![](Standard%20Group-Disabled.png)|Standard Group - Disabled|Indicates that capability to create Standard Groups is disabled.| |![](2018-11-20_11-55-08.png)|Block Group|Icon for a Block Transaction Group.| |![](Block%20Group-Disabled.png)|Block Group - Disabled|Indicates that capability to create Block Groups is disabled.| |![](2018-11-20_11-56-21.png)|Historical Group|Icon for a Historical Group.| |![](Historical%20Group-Disabled.png)|Historical Group - Disabled|Indicates that capability to create Historical Groups is disabled.| |![](2018-11-20_11-58-00.png)|Stored Procedure Group|Icon for a block Stored Procedure Group.| |![](Stored%20Procedure%20Group-Disabled.png)|Stored Procedure Group - Disabled|Indicates that capability to create Stored Procedure Groups is disabled.| ### ![](Vision.png) Vision Additional symbols (Badge icons) can show up to the right of these items. See the [Vision Designer Interface](ignition-modules\vision\vision-designer-interface\vision-designer-interface.md) page for an explanation. |Symbol|Name|Description| |:---:|:---|:---| |![](Client%20Event%20Scripts.png)|[Client Events](ignition-modules\vision\scripting-in-vision\client-event-scripts\client-event-scripts.md)|Scripts for events that execute in Vision Clients.| |![](Windows.png)|Windows|Folder for Windows within the Vision Module.| |![](2019-01-03_15-56-41main.png)|Window|Icon for a Main Window. Appears next to the Window name.| |![](editwindow.png)|Window - Editing| Indicates that this Window is currently open for editing.| |![](2019-01-03_15-55-48popup.png)|Popup Window|Icon for a Popup Window. Appears next to the Popup Window name.| |![](2019-01-03_15-54-03docked.png)|Docked Window|Icon for a Docked Window. Appears next to the Docked Window name.| |![](Templates.png)|Templates (project)| | |![](Templates.png)|Vision Templates (shared)|Workspace for the *shared* Vision Templates. Same icon is displayed next to the name of each Template. | |![](edittemplate.png)|Vision Templates - Editing| Indicates that this Template is currently open for editing.| ### ![](image2018-11-19_16-35-10.png) Named Queries |Symbol|Name|Description| |:---:|:---|:---| |![](Named%20Query.png)|Named Query|Create new Named Query.| |![](Named%20Query-Disabled.png)|Named Query - Disabled|Indicates that access to Global resources is disabled.| |![](Named%20Query-Editing.png)|Named Query - Editing|Icon for an individual Named Query. Clicking opens the Named Query for editing.| ### ![](image2018-11-19_16-35-1.png) Reports |Symbol|Name|Description| |:---:|:---|:---| |![](Report.png)| Report |Create new Report.| |![](Report-Disabled.png)|Report - Disabled|Indicates that capability to create a Report is disabled.| |![](Report-Editing.png)|Report - Editing|Icon for an individual report. Clicking opens the report for editing.| ### Right-Click Menu |Symbol|Name|Description| |:---:|:---|:---| |![](rename2019-07-11_17-04-37.png)|Rename|Renames the current selection.| |![](cut2019-07-11_17-05-04.png)|Cut|Cuts the current selection into the clipboard.| |![](copy2019-07-11_17-08-19.png)|Copy|Copies the current selection into the clipboard.| |![](copy%20path2019-07-11_17-05-37.png)|Copy Path|Copies the current path into the clipboard.| |![](paste2019-07-11_17-09-46.png)|Paste|Pastes the content in the clipboard into the selected context.| |![](delete2019-07-11_17-06-19.png)|Delete|Deletes the current selection.| |![](protect%202019-07-11_17-06-57.png)|Protect|Locks the individual project resource from inside Designer.|