title: "Remote Upgrade"
---
# Remote Upgrade
>
>
>
> Agents can be upgraded remotely from the Controller. This involves uploading the required binary files for the desired architecture as a task. Once the files have been saved, the remote upgrade procedure may be initiated. Both the Agent to be upgraded, as well as the Controller, must be on 7.9.2 to execute a Remote Upgrade.
Agents can be upgraded remotely from the Controller. This involves uploading the required binary files for the desired architecture as a task. Once the files have been saved, the remote upgrade procedure may be initiated. Both the Agent to be upgraded, as well as the Controller, must be on 7.9.2 to execute a Remote Upgrade.
## Upgrading Redundant Agents
When upgrading a redundant pair of agents, it is recommended that the backup be upgraded before the master.
## Remote Agent Upgrade Task
This task will upgrade the agent(s) upon execution.
This task takes zipped binary files for a version of Ignition, and saves them for upgrades later. Multiple files may be saved for different versions and architectures. Additional modules may be included, allowing for upgrades of [non-standard modules](getting-started/ignition-modules/additional-modules/additional-modules.md) to occur simultaneously.
:::note
The zipped binary files differ from the installers. The binary files may be found on the Ignition downloads page, listed below the installers.
:::

This task only needs to be executed once per version/architecture: multiple upgrades may be performed from the same files.
### Creating the Remote Agent Upgrade Task
1. From the Controller, navigate to the **Configure** > **Enterprise Administration** > **Agent Tasks**. Click on the **Create new Gateway Task** link.
2. Select the **Remote Agent Upgrade** task from the list of tasks, and then click **Next**.

3. On the **Task Scheduling** page, give the task a name. Like all tasks, you will specify either a group, or several agents, so providing a useful name will make the task easier to identify later. you can leave the schedule set to **Execute Immediately**.
:::note
This task does not upgrade the agent, it only prepares the files for later. You may continue without worry that the agent will be restarted.
:::
4. On the **Remote Agent Upgrade** page, click the **Choose File** button, navigate to the files you wish to upload, and click **OK**. Note that this page will state the architecture of the Agents that were selected in the previous step. Once finished, click **Next**.

5. Next, select any additional modules that should be included with this Task. Modules that are not included in the typical installation, including third party modules, may be added. Click the **Choose File** button, navigate to the module, and click **OK**. This step is optional, so regardless of whether you add custom modules, click **Next** when you're ready to move on.
6. The **Task Summary** page will appear. Review the information, and click **Finish**. The new task will run, and pass the files to the agent. Once complete, the agent will be prepared for a remote upgrade.
## Upgrading the Agent
Once the files have been passed to the Agent, a remote upgrade may be initiated from the **Controller's** web interface.

:::note
As with all upgrades, it is highly recommended to take a backup of the Agent before starting the upgrade process. Information on taking a backup from an Agent can be found on the [Agent Task - Backup and Restore](enterprise-administration/agent-tasks/backup-and-restore/backup-and-restore.md) page.
:::
### Remotely Upgrading an Agent
1. To begin a remote system upgrade, on the Controller, navigate to **Gateway** > **Configure** > **Enterprise Administration** > **Remote Upgrades**. Once the Remote Upgrades page appears, you may either click the **Upgrade** button next to the agent you wish to upgrade, or select multiple agents/groups and click the **Upgrade Selected** button.

2. A confirmation page will appear. Click the **Confirm** button when ready to proceed.
3. The Remote Upgrades page will appear again. This will report the status of the upgrade. Once complete, the Upgrade Status of the agent will show that the upgrade was successful