Controller Operations

The Controllers Operations page on the Gateway allows users to add changeset files that can then be transferred to other controller Gateways, and distributed to their agents. A changeset file is a .zip file that is made up of a single file or combination of Gateway exports, project exports, and tag exports files.

The ability to transfer changeset files between controllers allows configurations to be tested on development and QA deployments before applying them to production Gateways. The ability to communicate between EAM controllers through changeset files also allows for hierarchical configuration with a central controller that can act as the source of truth for enterprise environments. Central controllers will not interact directly with agents in large, multi-site Ignition environments, but instead coordinate changes and setup to other child controllers. These child controllers will then distribute changesets to their agents independently. Child controllers will additionally collect aggregated agent metrics that will be available back to the central controller.

Refer to the Gateway Tasks page for more information on how to transfer changeset files between controller Gateways and distribute changesets to agent Gateways.

Changeset files can also be applied locally on the current Gateway. To do so, expand the listed changeset's three dots menu, select Apply Locally, and then Apply.

Gathering Changeset Files​

Before adding any changeset files to the Gateway, the desired files from the Gateway or Designer should be exported. Accepted file types include .zip, .gwex, and .json. Alternatively, you can import a previously exported changeset .zip file to use again.

Exporting from the Designer​

Project files and tag exports can be collected from the Designer.

To create a project export file:

  1. Click File > Export from the top navigation bar.
  2. Select the project resources you want to export.
  3. Click Export.
  4. Select the file location to place the export, rename if needed, and click Save.

To create a tag export file:

  1. Access the Tag Browser.
  2. Right-click on a desired folder or selection of tags.
  3. Select Export.
  4. Select the file location to place the export, rename if needed, and click Save.

Exporting from the Gateway​

You can create Gateway .gwex export files from the Export & Import page on the Gateway.

To create a .gwex file:

  1. Navigate to Platform > System > Export & Import.

  2. Select the reources to export. Click Select All to include all resources in the export.

  3. Select Export to download the file to your local folder.

    The Exports & Imports Gateway page with the page navigation, select all, and export buttons highlighted.

Adding a Changeset​

When all the needed files for a changeset file have been exported and saved, you can now combine them to create a changeset file. Changeset files can be made up of a single file or multiple files.

To add a changeset file:

  1. Navigate to Network > Enterprise > Controller Operations.

  2. Click Add Changeset.

  3. Select your Changeset Method. In this example, we will be building a changeset from a collection of files. See the Exporting a Changeset section for more information on how to import a previously exported Changeset .zip file.

  4. Click Next.

    The Add Changeset form with the Selecting exported files method chosen.

  5. Fill in the Name field on the Configure Changeset form, and if desired, enter a Description.

  6. Select Add File to open the Upload form.

  7. Select Add File to choose the file to add to the changeset, and click Open.

  8. The Detected File Type will be automatically populated by the uploaded file, which will trigger related settings to appear:

    • When adding Gateway exports (GWEX), no further settings need to be configured.
    • When adding project exports (ZIP) from the Designer, you'll also need to select the Project Export Type and assign a Project Name.
    • When adding a tag export (JSON), you'll also need to enter a Target Path and Tag Provider.
  9. Click Import and Continue.

    The Upload form displaying the project export options, and the Import and Continue option selected.

  10. Repeat steps 6-9 until all necessary files have been added.

  11. Optionally, enter a Due Date that the changeset must be transferred by before it will be considered past due.

  12. Click Add Changeset.

The changeset file is now listed on the page. You can select Edit from a changeset's three dots menu to make any further changes, or Delete to remove it.

Exporting a Changeset​

Existing changesets can be exported and imported from the Gateway to local machines. To export a changeset, expand the changeset's three dots menu and select Export. The file will automatically begin downloading. Now that you have a previously exported Changeset file, the import option can be used.

To import a changeset file:

  1. Select Add Changeset.

  2. Select Import a previously exported Changeset .zip file.

  3. Click Next.

    The Add Changeset form with the Import method selected.

  4. Click Select File.

  5. Select a previously exported Changeset file.

  6. Click Open.

  7. Select Add Changeset.

The changeset file is now listed on the page with the same settings and name as it had when it was exported. Expand the three dots menu and select Edit to make any changes.

Changeset Details​

Each changeset has a Details panel that will show the information listed on the main page, including creation date, ID, source Gateway, and Due Date, as well as the list of files and their corresonding Item ID, Item Type, and Details names. The individual file details are displayed by the relevant settings for each file type.

Expand the changeset's three dots menu and select View Details to open the Details panel.

The Details panel for a Test changeset with only a project export file.

Changeset Settings​

SettingDescription
NameThe name of the changeset.
DescriptionThe description of the changeset.
Add FilesAdds exported files from the Gateway or the Designer to build a changeset. This may include Gateway exports, project exports (full or partial), or tag exports. Once added, the Filename, Item ID, and Type will be listed for each upload. Uploads can be deleted from the Add Files list by selecting the Remove option from the file's three dots menu. See the Upload Settings table for more information on settings per file type.
Due DateSets an optional due date for this Changeset. A warning indicator will display when the date has passed.

Upload Settings​

Once a project export or tag export is uploaded, the following settings will be displayed as applicable.

SettingDescription
Detected File TypeDisplays the file type uploaded based on the selected file’s extension:
  • Gateway Export: This type is displayed when .gwex files are selected.
  • Project Export: This type is displayed when .zip files are selected.
  • Tag Export: This type is displayed when .json files are selected.
Project Export TypeAssigns the .zip file as a full project or a partial project export. This setting will only appear for project exports.
Project NameSets the name the project will be created/replaced under. This setting will only appear for project exports.
Target PathAll tags in the selected file will be placed in this folder. If blank, all tags and UDT definitions will be placed into the provider’s root folder. This setting will only appear for tag exports.
Tag ProviderThe target tag provider. This setting will only appear for tag exports.