system.sfc.pauseChart

This function is used in Python Scripting.

Description​

Pauses a running chart instance. Any running steps will be told to pause, and the chart will enter Pausing state. Will throw a KeyError if the ID does not match any running chart instance.

Client Permission Restrictions​

Permission Type: SFC Management

Client access to this scripting function is blocked to users that do not meet the role/zone requirements for the above permission type. This function is unaffected when run in the Gateway scope.

Syntax​

system.sfc.pauseChart(id)

Parameters​

TypeParameterDescription
StringidThe ID of the chart instance to pause

Returns​

Nothing

Scope​

Gateway, Vision Client, Perspective Session

Code Examples​

Code Snippet
# The following attempts to pause a SFC.
id = 'Some long string value. It can be obtained using system.sfc.getRunningCharts()'

system.sfc.cancelChart(id)