Skip to main content
Version: 2027.02 Beta
View as Markdown

toDouble

This function is used by Ignition's Expression language.

Description​

Tries to coerce value into a double (64-bit floating point value). If value is a number, the conversion is direct. If value is a string, it is parsed to see if it represents a double. If not, type casting fails.

Syntax​

toDouble(value, [failover])

Parameters​

TypeParameterDescription
ObjectvalueThe value to type cast.
ObjectfailoverThe failover value if type casting fails. [optional]

Results​

Double - The value type cast as a double.

Examples​

Code Snippet
toDouble("38.772") //returns 38.772
Code Snippet
toDouble({Root Container.TextField.text}, 0.0) //returns the value in the text box as a double, or 0.0 if the value doesn't represent a number.