Perspective - Coordinate Container Scripting

This page details the component-specific events and functions available for Perspective's Coordinate Container component. Right-click on the component or select Components from the Designer menubar to access the Configure Events and Configure Scripts popups.

Component Events​

The Perspective Event Types Reference page describes all the possible component event types for Perspective components.

onPipeClicked​

This event will trigger when a pipe in this container is clicked.

note

This component event is designed to be used in tandem with a script runAction. Within the script action, special properties and methods are available on the event object, which is passed to the script action as a parameter.

event.event​

  • Object Path

    • event.event
  • Type

    • Dictionary
  • Description

    • The event object generated from the mouse click.

event.pipeIndex​

  • Object Path

    • event.pipeIndex
  • Type

    • Integer or float
  • Description

    • The array index of the pipe within props.pipes that was clicked.

event.pipeName​

  • Object Path

    • event.pipeName
  • Type

    • String
  • Description

    • The name of the pipe that was clicked.

Component Functions​

.getChildren()​

  • Description
    • Returns an ArrayList, which contains references to all components inside of the container.
  • Parameters
    • None
  • Return
    • Array List - An ArrayList of components in the container. The resulting ArrayList can be iterated over via a for-loop.

Extension Functions​