Skip to main content
Version: 2027.02 Beta
View as Markdown

Perspective - Breakpoint Container

Component Palette Icon:

Description​

The Breakpoint container consists of a single breakpoint, with two child views. In other words, using a Breakpoint container offers you a layout with the opportunity to create two different views that are shown at two distinct ranges of layout widths.

This allows for a very simple responsive design that removes one container and replaces it with another when the viewport width is changed. With the Breakpoint container, you can define completely different content to render for each child. This is in contrast to a container such as the column container, where the content for each breakpoint is identical but the layout of it changes according to screen size.

Breakpoint containers are ideal to use in cases where you want completely different components available between a mobile user or a desktop user, since the components in each breakpoint are completely separate instances. Thus, if you're attempting to make a responsive view, and a Flex container isn't quite giving the desired result, a Breakpoint container can be used to switch to a completely different container or view.

Properties​

Most Properties have binding options. For more information on Bindings, see Types of Bindings in Perspective. This section only documents the Props Category of properties. The other Categories are described on the Perspective Component Properties page.

NameDescriptionProperty Type
breakpointWidth (in pixels) breakpoint declarations for child layouts. When the container is sized below minWidth, child position rules will fall back to the next set breakpoint rules.value: numeric
currentBreakpointA read-only property that displays the container's current size according to its breakpoint. Values include small and large.value: string
determinantChoose between the height or width dimension that the Breakpoint container will use to break. Default is width.value: string
styleUse Style to customize the visual style of the component. The Style menu contains all the tools for modifying text, background, margins, and borders. You can also specify a style class.object

Child Component Position Properties​

When a component is placed inside of a Breakpoint container, it will inherit the position property listed below.

NameDescriptionProperty Type
sizeIndicates which child the component located in. Expected values are small and large.value: string

Component Scripts and Events​

Further component interaction and functionality can be configured for all components through scripting and event actions. Right-click on the component or select Components from the Designer menubar to access the configuration popups for both of these options:

  • Configure Events: Accesses the Event Configuration popup where you can configure actions to run in response to events to make the component dynamic. The Events Configurations page shows how to configure events and actions on a Perspective component.

  • Configure Scripts: Accesses the Script Configuration popup where custom methods and message handlers can be added. The Scripting in Perspective section details scripting fundamentals, creating custom methods, and using message handlers.

The Breakpoint Container component also has Component Functions associated with it. See the Perspective - Breakpoint Container Scripting page for more information.

Nested Breakpoint Containers Example​

In this example, we have a Breakpoint container nested inside a root Breakpoint container. The setup is as follows:

Containers

  • The nested Breakpoint container is used when the root Breakpoint container's size is less than 800 pixels.
  • The nested Breakpoint container will change when its size is less than 700 pixels.

Components

  • When the page is greater than 800 pixels, an XY Chart is displayed.
  • When the page is between 700 and 800 pixels, an empty Power Chart is shown.
  • When the page is less than 700 pixels, an Icon is displayed.

The relevant properties for this example are displayed below:

Root Breakpoint Container Properties

PropertyValue
Breakpoint800px

Nested Breakpoint Container Properties

PropertyValue
Breakpoint700px