--- title: "Perspective - Radar" description: "The Radar component compares multiple values across several dimensions simultaneously." --- # Perspective - Radar > The Radar component compares multiple values across several dimensions simultaneously. ![The default display for the Radar component.](imgs/radar-component.png) **Component Palette Icon:** ![The Radar component palette icon within the Perspective Components panel.](imgs/component-palette-icon.png) The Radar component compares multiple values across several dimensions simultaneously, making this chart ideal for multi-dimensional performance analysis. Each dimension creates an additional spoke on the chart and represents a specific metric to compare values. ## Properties |Name|Description|Property Type| |---|---|---| |data|Dataset powering the chart. Each row represents one radar dimension. Row value fields are then referenced in `axes.nameField` value for the dimension title, `axes.maxField` value for the dimension max limit, and each `series.valueField` value for the dimension values to plot. |array| |axes| Radar dimension definitions that control how the spokes are labeled and scaled. **nameField**: Field key from data to use as the axis label. Value is string.**maxField**: Field key from data to use as the maximum value for each axis. This property determines the scale of each spoke independently. Value is string.**shape**: Determines the grid shape. Selecting `polygon` will display straight-edged rings, while `circle` will display concentric circles. Value is string.**axisLine**: Spoke lines radiating from center.**visible**: Shows the spoke line when true. Value is boolean.**color**: Sets the color of the spoke line.**split**: Concentric grid ring configuration.**count**: Number of concentric grid rings between the center and outer edge. Value is numeric.**line**: Configures the visibility and color of the concentric grid ring lines.**area**: Configures the visibility and color of the alternating shaded bands betweeen concentric rings.**label**: Axis name labels at the outer edge of each spoke.**visible**: Shows the axis name label when true. Value is boolean.**fontSize**: Font size of the axis name labels. Overrides `elementStyle.fontSize` when both are set. Value is numeric.**color**: The color of the axis name labels. Overrides `elementStyle.color` when both are set.**elementStyle**: Text style for a label rendered onto a chart canvas, including typography, alignment, box styling, and shadow.|object| |series| Defines the fields to plot and how the polygon will render for each series.**label**: Field key from `data` to plot. One value per row, mapped to the corresponding axis. Value is string.**valueField**: Field key from `data` to plot. One value per row, mapped to the corresponding axis. Value is string.**color**: The polygon stroke and fill color. If left empty, color will be determined by `appearance.colorPalette`.**lineWidth**: The stroke width of the polygon in pixels. Value is numeric.**area**: Displays the polygon fill color, determined by the series color, when true. Value is boolean.|object| |legend|The legend display configuration. **visible**: Shows the legend when true. Value is boolean.**position**: Determines the legend placement. Value is string.**orientation**: Horizontal or vertical layout direction of legend names. Value is string.**interactive**: Clicking a legend item toggles series visibility. Can also be set to **single** or **multiple** for single and multiple selections. Value is boolean or string.**fontSize**: The font size of the legend item labels. Value is numeric. |object| |title| Chart title and subtitle. **visible**: Shows the title text when true. Value is boolean.**text**: Main title text. Value is string.**color**: The color of the title text. Overrides `elementStyle.color` when both are set.**fontSize**: The font size of the legend item labels. Value is numeric.**subtitle**: Configures the subtitle under the title, including text, color, size, and style.**position**: Determines the legend placement. Value is string.**gap**: Pixel gap between the main title and subtitle. Value is numeric.**elementStyle**: Text style for a label rendered onto a chart canvas, including typography, alignment, box styling, and shadow.|object| |appearance| Configures the chart theme and layout. **colorPalette**: Auto-assigned to any series without an explicit color, in order. **backgroundColor**: Chart background fill color. **fontSize**: Base font size for labels and tooltip text. Value is numeric.**radius**: Outer radius of the radar as a percentage of the container or absolute pixels. Value is numeric.**centerX**: Horizontal center position as a percentage of the container. Value is numeric.**centerY**: Vertical center position as a percentage of the container. Value is numeric.**tooltip**: Configures tooltip behavior. See the [tooltip properties](#tooltip-properties) below for more information.|object| |style|Style configuration for the chart. Full menu of [style options](appendix\reference-pages\style-reference.md) is available. You can also specify a [style class](ignition-modules\perspective\styles\style-classes\style-classes.md).|object| ### tooltip Properties |Name|Description|Property Type| |---|---|---| |visible| Shows the tooltip when true.|boolean| |format|Sets the tooltip display format. Configurations set here will apply to all pens. Options include: **type**: Sets the format type as either `value` or `template`, depending on whether the user wants to only customize the value display within the default tooltip format, or replace the default tooltip format entirely with a customized template. Value is string.**value/template**: Expression applied to each layout per the `format` type selected. The dropdown will display default options, but manual entries are accepted. Value is string. See the [tooltip Formatting Options](#tooltip-formatting-options) section for more descriptions and examples on how to customize a tooltip.|object| #### tooltip Formatting Options Tooltip display can be customized with the following built-in formatting properties and token options. Tokens serve as placeholders that will be replaced with live data during runtime. They are case-sensitve, include no spaces, and must be enclosed with curly braces. Index suffixes are accepted when entered as the series number following a colon. All tooltips will render using the en-US locale unless otherwise specified. When translated, text is processed as a whole phrase. Additionally, tooltips are HTML, so basic markup works within templates. However, the tooltip value expression is not HTML so `{value}` shows the value literally. The table below describes the available tokens that can be used, as well as some possible format examples. |Token|Description|Example Format|Example Output| |---|---|--------------|------------| |`{value}`| The y-axis value. When `value` is selected as the `format.type`, default dropdown options include `%`, `kW`, and `°F`. However, any unit can be entered before or after `{value}` by typing directly into the field for either type selection.|
`${value}`
|![](imgs/value.png)| |`{marker}`| Displays the `series[].color` selection as an identifying marker dot. Available for `template` types only.|
`{marker}{series}: {value}%`
|![](imgs/marker-series-value.png)| |`{series}`| Displays the `series[].label` text. Available under `template` types only.|
`{series}: {value}`
|![](imgs/bold-series.png)| |`{category}`|Displays the x-axis value. Available under `template` types only. |
`{category} — {marker}{series}: {value}`
|![](imgs/category.png)| |`{sum}`| Displays the total y-axis value for all series data sharing an x-axis category. Available under `template` types for stacked and diverging variants only. |
`{category} - {series:0}: {value:0}
``{category} - {series:1}: {value:1}` `{category}: {sum}`
|![](imgs/sum-proof.png)![](imgs/sum.png)| ## Component Scripts and Events The Radar component also has Component Events associated with it. See the [Perspective - Radar Scripting](perspective-radar-scripting.md) page for more information. ## Example The example chart uses the following `data` values for Lassie, Buddy, and Duke. These values are then referenced in the `series` configuration to assign the given values and titles. `data.0` * `dimension`: Strength * `max`: 10 * `lassie`: 6 * `buddy`: 8 * `duke`: 10 `data.1` * `dimension`: Agility * `max`: 10 * `lassie`: 8 * `buddy`: 4 * `duke`: 5 `data.2` * `dimension`: Intelligence * `max`: 10 * `lassie`: 10 * `buddy`: 3 * `duke`: 6 `data.3` * `dimension`: Appearance * `max`: 10 * `lassie`: 7 * `buddy`: 10 * `duke`: 4 `data.4` * `dimension`: Speed * `max`: 10 * `lassie`: 8 * `buddy`: 6 * `duke`: 4 ![Radar chart comparing skills and traits of Lassie, Buddy, and Duke.](imgs/example.png) |Property|Value| |---|---| |axes.nameField|dimension| |axes.maxField| max| |series.0.label| Lassie| |series.0.valueField| lassie| |series.0.color|#8A5516| |series.1.label| Buddy| |series.1.valueField| buddy| |series.1.color|#D6A508| |series.2.label| Duke| |series.2.valueField| duke| |series.2.color|#000000|